The present investigation was undertaken to evaluate the utility of constant-rate injection of a nonrecirculating indicator (H(2)) for the measurement of cardiac output in man. 42 patients were studied during cardiac catheterization and 8 during acute complications of arteriosclerotic heart disease, including acute myocardial infarction. Pulmonary (or systemic) arterial H(2) concentration was measured chromatographically from 2.0 ml blood samples drawn during constant-rate injection of dissolved H(2) into the systemic venous circulation (or left heart). The chromatograph was a thermal conductivity unit housed in a constant-temperature water bath to achieve an improved signal-to-noise ratio. Intrapulmonary H(2) elimination from mixed venous blood was measured directly in 14 patients and averaged 98 +/-1.5% (SD). Reproducibility of output measurements was evaluated using triplicate determinations obtained over 45-60 sec in 25 consecutive patients. Coefficients of variation (SD/Mean x 100) averaged 3.4 +/-2.0%, making it possible to evaluate relatively small changes in measured output with conventional statistical tests. Individual measurements could be repeated at 10-15 sec intervals. Comparisons of H(2) and direct Fick measurements were made in 14 patients; H(2) outputs averaged 106 +/-4% (SEM) of Fick outputs (P > 0.1). Comparisons of H(2) and dye dilution measurements were performed in an additional 24 patients. Seven had angiographically-negligible valvular regurgitation and dye outputs averaged 106 +/-3% of H(2) outputs (P > 0.1). 17 had moderate-to-severe regurigation and dye outputs averaged 91 +/-4% of H(2) outputs (P < 0.05), suggesting a small but systematic error due to undetected recirculation of dye. The H(2) technique appears advantageous for rapidly repeated determinations of output, for quantitation of small changes in output, and for situations in which recirculation of conventional indicators is a potentially significant problem.
[1]
M G Harries,et al.
Ventricular fibrillation as a complication of salt-water immersion.
,
1981,
British medical journal.
[2]
J. Bassingthwaighte,et al.
Flow Estimation by Indicator Dilution (Bolus Injection): Reduction of Errors Due to Time-Averaged Sampling During Unsteady Flow
,
1970,
Circulation research.
[3]
M. Levitt.
Production and excretion of hydrogen gas in man.
,
1969,
The New England journal of medicine.
[4]
A. Oriol,et al.
Indicator-dilution methods in estimation of cardiac output in clinical shock.
,
1967,
The American journal of cardiology.
[5]
A. Oriol,et al.
Limitations of indicator-dilution methods in experimental shock.
,
1967,
Journal of applied physiology.
[6]
T. Yokoyama,et al.
Effects of ventilation-perfusion inequality on elimination of inert gases.
,
1967,
Respiration physiology.
[7]
N. Lassen,et al.
Right-to-left shunt in normal man determined by the use of tritium and krypton 85
,
1962
.
[8]
E. Wood,et al.
Apparent dye-dilution curves produced by injection of transparent solutions
,
1961
.
[9]
F. Klocke.
Measurement of Trace Amounts of Inert Gases in Blood by Gas Chromatography
,
1967
.
[10]
C. Chidsey,et al.
Fate of radioactive kryton (Kr85) introduced intravenously in man.
,
1959,
Journal of applied physiology.