RF‐induced temperature elevation along metallic wires in clinical magnetic resonance imaging: Influence of diameter and length

With the development of interventional MRI, heating of biological tissues along the metallic wires in the MRI scanner has become an important issue. To assess thermal response to RF exposure during MRI, we studied the temperature elevation near nonmagnetic metallic wires. All tests were performed on a 1.5 T clinical scanner. Four experiments were conducted to investigate the effects of the wire diameter, the excitation flip angle, the temperature distribution along the wire, and the wire length. Electromagnetic simulations of the experimental setup were made with the use of commercial method of moments (MoM) software and numerical simulations of Hallén's equations. Comparisons between measured and calculated values of the electric field are presented. This study demonstrates that 1) temperature decreases with the diameter of the wire,2)temperature increases quadratically with the excitation flip angle, 3) heating occurs not only at the tip but also along the wire, and 4) the heating peaks are not obtained for the classical resonant length multiple of λ/4 (where λ is the RF field wavelength). In addition, significant and rapid heating increases were observed in the close vicinity of the wire. Magn Reson Med 52:1200–1206, 2004. © 2004 Wiley‐Liss, Inc.

[1]  Keyvan Farahani,et al.  Safety of MRI‐guided endovascular guidewire applications , 2000 .

[2]  Robert C. Susil,et al.  RF safety of wires in interventional MRI: Using a safety index , 2002 .

[3]  C J Bakker,et al.  Heating Around Intravascular Guidewires by Resonating RF Waves , 2000, Journal of magnetic resonance imaging : JMRI.

[4]  Modeling of RF heating due to metal implants in MRI , 2002, IEEE Antennas and Propagation Society International Symposium (IEEE Cat. No.02CH37313).

[5]  E. Hallén Theoretical investigations into the transmitting and receiving qualities of antennáe , 1938 .

[6]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. , 1948, Journal of applied physiology.

[7]  Bensheng Qiu,et al.  Using an MR imaging-guidewire as an intravascular local heating source: toward thermal enhancement of vascular gene transfection , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[8]  F G Shellock,et al.  Radiofrequency Energy‐Induced Heating During MR Procedures: A Review , 2000, Journal of magnetic resonance imaging : JMRI.

[9]  F. Pilleul,et al.  Optimization of endoluminal loop radiofrequency coils for gastrointestinal wall MR imaging , 2004, IEEE Sensors Journal.

[10]  E Atalar,et al.  A Green's function approach to local rf heating in interventional MRI. , 2001, Medical physics.

[11]  W. Nitz,et al.  On the heating of linear conductive structures as guide wires and catheters in interventional MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[12]  B. Condon,et al.  Investigation of the factors responsible for burns during MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[13]  Frank G Shellock,et al.  Magnetic resonance safety update 2002: Implants and devices , 2002, Journal of magnetic resonance imaging : JMRI.

[14]  Ergin Atalar,et al.  of the 23 rd Annual EMBS International Conference , October 25-28 , Istanbul , Turkey RF Safety of Wires in Interventional MRI : Using a Safety Index , 2004 .

[15]  O Dössel,et al.  THERMAL HEATING OF HUMAN TISSUE INDUCED BY ELECTRO-MAGNETIC FIELDS OF MAGNETIC RESONANCE IMAGING , 2002, Biomedizinische Technik. Biomedical engineering.

[16]  E. Atalar,et al.  Development of an intravascular heating source using an MR imaging guidewire , 2002, Journal of magnetic resonance imaging : JMRI.

[17]  E. Atalar,et al.  RF Transmit Power Limit for the Barewire Loopless Catheter Antenna , 2000, Journal of magnetic resonance imaging : JMRI.

[18]  R. C. Susil,et al.  RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field , 2002, Magnetic resonance in medicine.

[19]  Gesine Hellwig,et al.  Estimation of heat transfer and temperature rise in partial-body regions during MR procedures: an analytical approach with respect to safety considerations. , 2002, Magnetic resonance imaging.