Determining the concentration of easily assimilable organic carbon in drinking water

This paper describes a method for determining the potential of a water for supporting microbial regrowth in a drinking water distribution system. The method is based on the growth of fluorescent pseudomonads as a function of the concentration of easily assimilable organic carbon (AOC) in water. Using this method, the authors analyzed water samples from various stages of water treatment and water in which samples of nonmetallic piping materials had been placed. The concentration of AOC in water increased if the water was ozonated or placed in contact with plasticized polyvinylchloride. Without residual disinfectant in a

[1]  Edward S. K. Chian,et al.  Identification of end products resulting from ozonation and chlorination of organic compounds commonly found in water , 1977 .

[2]  Hugo T. Victoreen,et al.  Control of Water Quality in Transmission and Distribution Mains , 1974 .

[3]  J Kaustová,et al.  Endemic occurrence of Mycobacterium kansasii in water-supply systems. , 1981, Journal of hygiene, epidemiology, microbiology, and immunology.

[4]  M. Lechevallier,et al.  Enumeration and characterization of standard plate count bacteria in chlorinated and raw water supplies , 1980, Applied and environmental microbiology.

[5]  D Schoenen,et al.  [Coating and casing materials in drinking water containers. Practical observations and experimental findings]. , 1978, Gesundheits-Ingenieur.

[6]  D A Brown,et al.  Dissolved oxygen utilization as an indicator of total microbial activity on non-metallic materials in contact with potable water. , 1979, The Journal of applied bacteriology.

[7]  Mofizud-Din Ahmed,et al.  Pyrolysis of Humic Acids Prepared from Oxidized Bituminous Coal , 1950 .

[8]  Edwin E. Geldreich,et al.  The Necessity of Controlling Bacterial Populations in Potable Waters: Community Water Supply , 1972 .

[9]  Olli H. Tuovinen,et al.  Bacterial, chemical, and mineralogical characteristics of tubercles in distribution pipelines , 1980 .

[10]  W. A. M. Hijnen,et al.  Utilization of Low Concentrations of Starch by a Flavobacterium Species Isolated from Tap Water , 1981, Applied and environmental microbiology.

[11]  W. A. M. Hijnen,et al.  Growth of Aeromonas hydrophila at Low Concentrations of Substrates Added to Tap Water , 1980, Applied and environmental microbiology.

[12]  V. Yu,et al.  POTABLE WATER SUPPLY AS THE HOSPITAL RESERVOIR FOR PITTSBURGH PNEUMONIA AGENT , 1982, The Lancet.

[13]  J S Colbourne,et al.  Techniques for the assessment of growth of micro-organisms on plumbing materials used in contact with potable water supplies. , 1977, The Journal of applied bacteriology.

[14]  Shankha K. Banerji,et al.  Biologically mediated corrosion and its effects on water quality in distribution systems , 1980 .

[15]  D. Kooij,et al.  The occurrence of Pseudomonas spp. in surface water and in tap water as determined on citrate media , 1977, Antonie van Leeuwenhoek.

[16]  W. Ellgas,et al.  Reservoir coatings can support bacterial growth , 1980 .

[17]  Norman J. Howard Bacterial Depreciation of Water Quality in Distribution Systems , 1940 .

[18]  Mofizud-Din Ahmed,et al.  Ozonization of Humic Acids Prepared from Oxidized Bituminous Coal , 1950 .

[19]  R. Seidler,et al.  Klebsielleae in drinking water emanating from redwood tanks , 1977, Applied and environmental microbiology.

[20]  M. Doudoroff,et al.  The aerobic pseudomonads: a taxonomic study. , 1966, Journal of general microbiology.

[21]  A H Havelaar,et al.  The occurrence of Mycobacterium kansasii in tapwater. , 1980, Tubercle.

[22]  Allan B. Edwards,et al.  Deterioration of Water Quality in Distribution Systems , 1975 .