Radiologic evaluation of painful joint prostheses.

The most important method of evaluation of painful total joint prostheses is review of sequential radiographs. Because clinical failure from loosening occurs late, abnormalities of alignment, the cement-bone or cement-metal interface, the bony contour, or the integrity of the prosthetic components will be found in the vast majority of cases of clinical failure. In cases in which plain radiographs are normal or equivocal, radionuclide bone scanning with Tc-99m diphosphonate agents are useful. A diffuse increase in vascularity and in uptake of radionuclide is present in infection, while a normal scan suggests that infection or loosening is unlikely. Positive arthrograms are helpful in confirming loosening and in demonstrating abscess cavities and sinus tracts, but negative arthrograms have little significance. Asymptomatic patients with radiographic evidence of loosening should be followed with sequential roentgenograms for signs of progressive bone destruction.

[1]  J. Rodrigo,et al.  Arthrography for the assessment of pain after total hip replacement. A comparison of arthrographic findings in patients with and without pain. , 1975, The Journal of bone and joint surgery. American volume.

[2]  A. Hadjipavlou,et al.  99mTc-PP and 67Ga imaging following insertion of orthopedic devices. , 1979, Radiology.

[3]  B. Ghelman Three methods for determining anteversion and retroversion of a total hip prosthesis. , 1979, AJR. American journal of roentgenology.

[4]  I. Clarke,et al.  Improved methods for quantitative radiographic evaluation with particular reference to total-hip arthroplasty. , 1976, Clinical orthopaedics and related research.

[5]  B. Ghelman,et al.  Radiologic diagnosis of loosening and infection in hip prostheses. , 1977, Journal of the Canadian Association of Radiologists.

[6]  T. Slooff The influence of acrylic cement. , 1971, Acta orthopaedica Scandinavica.

[7]  S. Hughes Radionuclides in orthopaedic surgery. , 1980, The Journal of bone and joint surgery. British volume.

[8]  C. D. Teates,et al.  Radionuclide bone imaging as a means of differentiating loosening and infection in patients with a painful total hip prosthesis. , 1979, Radiology.

[9]  Å. Ahlberg,et al.  The radiolucent zone in arthroplasty of the knee. , 1977, Acta orthopaedica Scandinavica.

[10]  B. Wroblewski,et al.  Revision of the Charnley low-friction arthroplasty for recurrent or irreducible dislocation. , 1981, The Journal of bone and joint surgery. British volume.

[11]  C. M. Reing,et al.  Differential bone-scanning in the evaluation of a painful total joint replacement. , 1979, The Journal of bone and joint surgery. American volume.

[12]  J. Charnley,et al.  A radiological study of fractures of acrylic cement in relation to the stem of a femoral head prosthesis. , 1975, Journal of Bone and Joint Surgery-british Volume.

[13]  P. D. Wilson,et al.  Subtraction technique in arthrography for loosening of total hip replacement fixed with radiopaque cement. , 1974, Clinical orthopaedics and related research.

[14]  H C Amstutz,et al.  Complications of trochanteric osteotomy in total hip replacement. , 1978, The Journal of bone and joint surgery. American volume.

[15]  M. Semlitsch,et al.  Reaction of bone to methacrylate after hip arthroplasty: a long-term gross, light microscopic, and scanning electron microscopic study. , 1974, The Journal of bone and joint surgery. American volume.

[16]  J. Hsu,et al.  Heterotopic ossification around the hip in spinal cord-injured patients. A long-term follow-up study. , 1978, The Journal of bone and joint surgery. American volume.

[17]  H. Laborit,et al.  [Experimental study]. , 1958, Bulletin mensuel - Societe de medecine militaire francaise.

[18]  P. D. Wilson,et al.  Radiology of total hip replacements. , 1976, Clinical orthopaedics and related research.

[19]  H. Amstutz,et al.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. , 1979, Clinical orthopaedics and related research.

[20]  E. Chao,et al.  Fracture of the femoral component after total hip replacement. An analysis of fifty-eight cases. , 1981, The Journal of bone and joint surgery. American volume.

[21]  B. Ghelman Radiographic localization of the acetabular component of a hip prosthesis. , 1979, Radiology.

[22]  T. Slooff The Influence of Acrylic Cement: An Experimental Study , 1971 .

[23]  R. Coleman,et al.  Radiography, radionuclide imaging, and arthrography in the evaluation of total hip and knee replacement. , 1978, Radiology.

[24]  H. Genant,et al.  Loosening of the total knee arthroplasty: detection by radionuclide bone scanning. , 1980, AJR. American journal of roentgenology.

[25]  J. Tehranzadeh,et al.  Radiological evaluation of painful total hip replacement. , 1981, Radiology.

[26]  F. Reckling,et al.  A longitudinal study of the radiolucent line at the bone-cement interface following total joint-replacement procedures. , 1977, The Journal of bone and joint surgery. American volume.