A novel conversion method for radiographic guide into surgical guide

BACKGROUND The study proposed a novel method for converting a radiographic guide into a surgical guide and evaluated its accuracy. MATERIALS AND METHODS Radiographic guide was reformed with the addition of index rods for geometric conversion method (GCM). Planning implants were projected on geometric projection planes, and the implant positions were measured. The radiographic guide was converted into surgical guide using a generic bench drill machine with GCM data. Two experiments were designed to validate the GCM. (1) In vitro test: Twenty implants were placed on five edentulous dental models by using the GCM (group 1) and Stereolithography (SLA) method (group 2), respectively. The deviations of planned and placed implant were calculated, and the precision error (PE) value was calculated to evaluate the stability of the GCM and SLA. (2) In vivo test: Nine edentulous subjects were selected for clinical implant surgery with the GCM guide. Two level of the index rods of radiographic guides were prepared for surgical guides forming. The differences between the planned and actual implants were calculated in implant head, apex, and angulation. RESULTS The in vitro test revealed no significant differences in the planned and placed angulations between groups 1 and 2 (P > .05). The PE was not significantly different between groups 1 and 2 (P > .05). The in vivo test revealed a successful treatment of the subjects, and 16 implant sites were evaluated. The results indicated that GCM guide could achieve the three-dimensional (3D) offset deviations of 1.03 ± 0.27 mm and 1.17 ± 0.24 mm at the implant head and apex, respectively, and 1.37° ± 0.21° for the 3D angulation. CONCLUSION The novel method for converting a radiographic guide into a surgical guide appears accurate and stable compared with SLA.

[1]  Thomas Fortin,et al.  Panoramic images versus three-dimensional planning software for oral implant planning in atrophied posterior maxillary: a clinical radiological study. , 2013, Clinical implant dentistry and related research.

[2]  Wei-Shao Lin,et al.  Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report. , 2014, The Journal of prosthetic dentistry.

[3]  Marc Quirynen,et al.  Tolerance within the sleeve inserts of different surgical guides for guided implant surgery. , 2013, Clinical oral implants research.

[4]  Eitan Barnea,et al.  Accuracy of a laboratory-based computer implant guiding system. , 2010, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[5]  G. Polizzi,et al.  Five-year follow-up of immediate fixed restorations of maxillary implants inserted in both fresh extraction and healed sites using the NobelGuide™ system. , 2015, Clinical implant dentistry and related research.

[6]  I. Turkyilmaz,et al.  Impact of operator experience on the accuracy of implant placement with stereolithographic surgical templates: an in vitro study. , 2013, The Journal of prosthetic dentistry.

[7]  Jacob Rosen,et al.  Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study. , 2009, The Journal of prosthetic dentistry.

[8]  Filip Schutyser,et al.  An Accuracy Study of Computer-Planned Implant Placement in the Augmented Maxilla Using Mucosa-Supported Surgical Templates. , 2015, Clinical implant dentistry and related research.

[9]  E. Pow,et al.  Stereoscopic technique for conversion of radiographic guide into implant surgical guide. , 2013, Clinical implant dentistry and related research.

[10]  K. Koyano,et al.  Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study , 2015, Clinical and experimental dental research.

[11]  Luc M. Verhamme,et al.  A clinically relevant validation method for implant placement after virtual planning. , 2012, Clinical oral implants research.

[12]  J. D. da Silva,et al.  Accuracy and complications of computer-designed selective laser sintering surgical guides for flapless dental implant placement and immediate definitive prosthesis installation. , 2012, Journal of periodontology.

[13]  Jean Loup Coudert,et al.  An image-guided system-drilled surgical template and trephine guide pin to make treatment of completely edentulous patients easier: a clinical report on immediate loading. , 2004, Clinical implant dentistry and related research.

[14]  P. Cattin,et al.  Accuracy of full guided vs. half-guided implant surgery. , 2013, Clinical oral implants research.

[15]  R Jacobs,et al.  Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. , 2007, Journal of clinical periodontology.

[16]  Sebastian Kühl,et al.  Technical accuracy of printed surgical templates for guided implant surgery with the coDiagnostiX ™ software. , 2015, Clinical implant dentistry and related research.

[17]  S. Arzanpour,et al.  The effects of implant angulation on the resonance frequency of a dental implant. , 2014, Medical engineering & physics.

[18]  M. Zwahlen,et al.  A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. , 2009, Clinical oral implants research.

[19]  David Anssari Moin,et al.  A Novel Approach for Computer-Assisted Template-Guided Autotransplantation of Teeth With Custom 3D Designed/Printed Surgical Tooling. An Ex Vivo Proof of Concept. , 2016, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[20]  Volkan Arısan,et al.  Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. , 2010, Clinical oral implants research.

[21]  R. Haas,et al.  Esthetics of Flapless Single-Tooth Implants in the Anterior Maxilla Using Guided Surgery: Association of Three-Dimensional Accuracy and Pink Esthetic Score. , 2015, Clinical implant dentistry and related research.

[22]  Gerlig Widmann,et al.  Accuracy of Image-Fusion Stereolithographic Guides: Mapping CT Data with Three-Dimensional Optical Surface Scanning. , 2015, Clinical implant dentistry and related research.

[23]  S. Rosenstiel,et al.  Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[24]  M. Cassetta,et al.  The intrinsic error of a stereolithographic surgical template in implant guided surgery. , 2013, International journal of oral and maxillofacial surgery.

[25]  Dmd Fmcds Mmi PhD Researcher Jimoh Olubanwo Agbaje Bds Accuracy of Dental Implant Placement Using CBCT-Derived Mucosa-Supported Stereolithographic Template , 2013 .

[26]  Ilser Turkyilmaz,et al.  Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study. , 2012, The Journal of prosthetic dentistry.

[27]  Jean-Luc Bosson,et al.  Flapless implant surgery using an image-guided system. A 1- to 4-year retrospective multicenter comparative clinical study. , 2009, Clinical implant dentistry and related research.

[28]  P. Shen,et al.  Accuracy evaluation of computer-designed surgical guide template in oral implantology. , 2015, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.