A Dual Second-Order SOGI based Control Algorithm for UPQC under Distorted Grid and Load Conditions

This paper presents a Second-Order Second Order Generalized Integrator (SO-SOGI) based control algorithm for UPQC (Unified Power Quality Conditioner), an integration of DVR and DSTATCOM. This paper mainly aims to mitigate source voltage and load current harmonics, unbalance and power factor improvement. In this paper, SO-SOGI-PLL (Phase-Locked Loop) is employed for UPQC to generate reference voltage and current signals for enhancing power quality at the utility mains. SO-SOGI based PLL is utilized for power quality enhancement because of its dynamic response, better harmonic and inter harmonic compensation, tracking accuracy and faster detection of reference signal under all varying load and grid conditions. The proposed three-phase UPQC is utilized for mitigation of voltage harmonics, current harmonics, sag and swell with a simple control technique. The control algorithm is tested and evaluated using MATLAB/Simulink.

[1]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[2]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[3]  J. S. Hsu Instantaneous phasor method for obtaining instantaneous balanced fundamental components for power quality control and continuous diagnostics , 1997 .

[4]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[5]  A. Baggini,et al.  Power quality , 2004, Proceedings. 2004 First International Conference on Power Electronics Systems and Applications, 2004..

[6]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[7]  Angelo Baggini,et al.  Handbook of Power Quality , 2008 .

[8]  Mohammad A. S. Masoum,et al.  Power Quality in Power Systems and Electrical Machines , 2008 .

[9]  Bhim Singh,et al.  Comparison of three control algorithms for single-phase UPQC , 2011, 2011 International Conference on Energy, Automation and Signal.

[10]  P. Sekhar,et al.  Power Quality Enhancement Using Custom Power Devices , 2012 .

[11]  M. Karimi-Ghartemani,et al.  A Unifying Approach to Single-Phase Synchronous Reference Frame PLLs , 2013, IEEE Transactions on Power Electronics.

[12]  Hareesh Kumar Yada,et al.  A new topology and control strategy for extraction of reference current using single phase SOGI-PLL for three-phase four-wire Shunt Active Power Filter , 2014, 2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).

[13]  F. Blaabjerg,et al.  An Improved Second-Order Generalized Integrator Based Quadrature Signal Generator , 2016, IEEE Transactions on Power Electronics.