Accurate analysis of formose reaction products by LC-UV: an analytical challenge.

This study presents a liquid chromatography-ultraviolet (LC-UV) method for the accurate analysis of formose reaction products with regard to sum parameters. Limitations encountered in gas chromatography (e.g., thermal stability of analytes) were overcome. First, alditols are O-benzoylated and subjected to reversed-phase chromatography. They are then detected by UV and by electrospray ionization-mass spectrometry (ESI-MS) for validation purposes. Compared with standard 2,4-dinitrophenylhydrazine labeling, the accuracy of results from LC-UV is dramatically improved due to enhanced chromatographic resolution and validation by ESI-MS. For the first time ever, LC-UV may be used to accurately quantify 2-hydroxymethylglycerol, a branched chain alditol, D,L-glyceraldehyde, D,L-galactose, which represents the group of D,L-iditol/galactose/glucose/mannose and D,L-erythrose in formose reaction products.

[1]  A. I. Ruiz-Matute,et al.  Derivatization of carbohydrates for GC and GC-MS analyses. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[2]  A. Duarte,et al.  Development and application of a capillary electrophoresis based method for the assessment of monosaccharide in soil using acid hydrolysis. , 2007, Talanta.

[3]  J. Lehrfeld Separation of some perbenzoylated carbohydrates by high-performance liquid chromatography , 1976 .

[4]  Hong-xia Li,et al.  Measurement of serum total glycerides and free glycerol by high-performance liquid chromatography1 Published, JLR Papers in Press, June 20, 2006. , 2006, Journal of Lipid Research.

[5]  Y. Mechref,et al.  Multiple-reaction monitoring liquid chromatography mass spectrometry for monosaccharide compositional analysis of glycoproteins , 2009, Journal of the American Society for Mass Spectrometry.

[6]  A. Venter,et al.  Journal of The American Society for Mass Spectrometry , 2005, Journal of the American Society for Mass Spectrometry.

[7]  M. Holčapek,et al.  Basic rules for the interpretation of atmospheric pressure ionization mass spectra of small molecules. , 2010, Journal of chromatography. A.

[8]  K. Bächmann,et al.  Determination of carbonyl compounds in the low ppb-range by capillary electrophoresis , 1993 .

[9]  Peter Decker,et al.  Bioids : X. Identification of formose sugars, presumable prebiotic metabolites, using capillary gas chromatography/gas chromatography—mas spectrometry of n-butoxime trifluoroacetates on OV-225 , 1982 .

[10]  Md Zafar Iqbal,et al.  Analysis of formose sugar and formaldehyde by high-performance liquid chromatography. , 2009, Journal of chromatography. A.

[11]  T. Ioneda,et al.  Chromatographic and mass spectrometric analyses of 1-monomycoloyl glycerol fraction from Rhodococcus lentifragments as per-O-benzoyl derivatives , 1996 .

[12]  A. Jeanes,et al.  Quantitative Determination of Monosaccharides as Their Alditol Acetates by Gas Liquid Chromatography. , 1965 .

[13]  I. Blasig,et al.  Benzoylation of sugars, polyols and amino acids in biological fluids for high-performance liquid chromatographic analysis. , 1994, Journal of chromatography. B, Biomedical applications.

[14]  C. Sarkar,et al.  A sensitive assay of red blood cell sorbitol level by high performance liquid chromatography: potential for diagnostic evaluation of diabetes. , 2005, Clinica chimica acta; international journal of clinical chemistry.

[15]  R. Stick Carbohydrates: The Sweet Molecules of Life , 2001 .

[16]  Y. Mechref,et al.  Quantification of monosaccharides through multiple-reaction monitoring liquid chromatography/mass spectrometry using an aminopropyl column. , 2010, Rapid communications in mass spectrometry : RCM.

[17]  Nikos Karamanos High-Performance Liquid Chromatographic Determination of Xylitole and Hexosaminitols Present in the Reduced Terminal of Glycosaminoglycans , 1993 .