Oscillometric blood pressure estimation using principal component analysis and neural networks

Estimation of systolic and diastolic pressures from the oscillometric waveform is a challenging task in noninvasive electronic blood pressure (BP) monitoring devices. Since the conventional oscillometric algorithms cannot model and extract the complex and nonlinear relationship that may exist between BP and oscillometric waveform, artificial neural networks (NNs) have been proposed as a possible alternative. However, the research on this topic has been limited to some simple architectures that directly estimate the BP from raw oscillation amplitudes (OAs). In this paper, we propose principal component analysis as a preprocessing step to decorrelate the OAs and extract the most effective components. Two architectures of NNs, namely, feed-forward and cascade-forward, are employed to estimate the BP using the preprocessed OAs. The networks are trained using the gradient descent with momentum and adaptive learning rate backpropagation algorithm and tested on a dataset of 85 BP waveforms. The performance is then compared with that of the conventional maximum amplitude algorithm and already published NN-based methods. It is found that the proposed networks achieve lower values of mean absolute error and standard deviation of error in estimation of BP compared with the other studied methods.

[1]  Ian T. Jolliffe,et al.  Principal Component Analysis , 2002, International Encyclopedia of Statistical Science.

[2]  Dwayne Westenskow,et al.  Noninvasive blood pressure monitoring from the supraorbital artery using an artificial neural network oscillometric algorithm , 1995, Journal of Clinical Monitoring.

[3]  E. Mizutani,et al.  Neuro-Fuzzy and Soft Computing-A Computational Approach to Learning and Machine Intelligence [Book Review] , 1997, IEEE Transactions on Automatic Control.

[4]  M. Bolic,et al.  Assessment of algorithms for oscillometric blood pressure measurement , 2009, 2009 IEEE Instrumentation and Measurement Technology Conference.

[5]  David Goff,et al.  Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society Of Hypertension, and Preventive Cardiovascular Nurses Association. , 2008, Hypertension.

[6]  L. Geddes,et al.  Characterization of the oscillometric method for measuring indirect blood pressure , 2006, Annals of Biomedical Engineering.

[7]  G. Drzewiecki,et al.  Theory of the oscillometric maximum and the systolic and diastolic detection ratios , 2006, Annals of Biomedical Engineering.

[8]  David Goff,et al.  Call to Action on Use and Reimbursement for Home Blood Pressure Monitoring: A Joint Scientific Statement From the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association , 2008, The Journal of cardiovascular nursing.

[9]  Junita Mohamad-Saleh,et al.  Improved Neural Network Performance Using Principal Component Analysis on Matlab , 2008 .

[10]  F. Forster,et al.  Oscillometric determination of diastolic, mean and systolic blood pressure--a numerical model. , 1986, Journal of biomechanical engineering.

[11]  C. Small,et al.  Survey of automated noninvasive blood pressure monitors. , 1994, Journal of clinical engineering.

[12]  Martin T. Hagan,et al.  Neural network design , 1995 .