Design of a Magnetic Localisation System for In-Vivo Endovascular Interventions

Endovascular catheterisation is performed by an interventional radiologist using fluoroscopic guide and contrast-media. The X-Ray exposure both of the patient and of the operators can induce heavy collateral effects. The present paper describes an innovative magnetic position/orientation indicator capable to drive the endovascular probe during in- vivo medical diagnostic or interventional procedures. It uses the magnetic field produced by a thin permanent magnet installed on the endovascular probe and magnetic field sensors positioned outside the patient body: this allow the elimination of repetitive X-Ray scans used to monitor the probe position. The aims of the proposed system are: to drive the catheter inside the patient vascular tree with a reduction of the X-Ray exposure both of the patient and of the personnel involved in the intervention; to allow a more comfortable operative condition for the personnel due to the reduction of the time they wear X-Ray protective systems. The paper reports the mathematical problem formulation, the numerical simulations for the magnetic field calculation produced by the thin endovascular permanent magnet and the system design of the usable hardware.

[1]  H. Herrmann Comparison of angioplasty with stenting in acute myocardial infarction. , 2002, The New England journal of medicine.

[2]  Eduard Gröller,et al.  Real-Time Maximum Intensity Projection , 1999, VisSym.

[3]  J. Ottervanger,et al.  Reperfusion therapy in elderly patients with acute myocardial infarction: a randomized comparison of primary angioplasty and thrombolytic therapy. , 2002, Journal of the American College of Cardiology.

[4]  T Stijnen,et al.  Balloon dilation and stent implantation for treatment of femoropopliteal arterial disease: meta-analysis. , 2001, Radiology.

[5]  Y. Yamashita,et al.  5-Fluorouracil Intra-arterial Infusion Combined With Systemic Gemcitabine for Unresectable Pancreatic Cancer , 2005, Pancreas.

[6]  M. Bauer,et al.  Interactive volume on standard PC graphics hardware using multi-textures and multi-stage rasterization , 2000, Workshop on Graphics Hardware.

[7]  David G. Pettifor,et al.  Perspectives of giant magnetoresistance , 2001 .

[8]  Charles R. Westgate,et al.  The Hall effect and its applications , 1980 .

[9]  A. Baert Renal artery stent placement. , 1994, Radiology.

[10]  J M Bland,et al.  Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): a randomised trial , 2001, The Lancet.

[11]  P. Breslau,et al.  Percutaneous transluminal dilatation of the iliac artery: long-term results. , 1985, Radiology.

[12]  Georgios Sakas,et al.  Optimized Maximum Intensity Projection (MIP) , 1995, Rendering Techniques.

[13]  Milos Srámek,et al.  Fast surface rendering from raster data by voxel traversal using chessboard distance , 1994, Proceedings Visualization '94.

[14]  J. Bland,et al.  Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): a randomised trial , 2001, The Lancet.

[15]  N. Avril,et al.  90Y microsphere treatment of unresectable liver metastases: changes in 18F-FDG uptake and tumour size on PET/CT , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[16]  Eugenio Picano,et al.  Informed consent and communication of risk from radiological and nuclear medicine examinations: how to escape from a communication inferno , 2004, BMJ : British Medical Journal.

[17]  F. Raab,et al.  Magnetic Position and Orientation Tracking System , 1979, IEEE Transactions on Aerospace and Electronic Systems.

[18]  J. Parodi,et al.  Transfemoral intraluminal graft implantation for abdominal aortic aneurysms , 1991, Annals of vascular surgery.

[19]  M. J. D. Powell,et al.  An efficient method for finding the minimum of a function of several variables without calculating derivatives , 1964, Comput. J..

[20]  J. J. Griffin,et al.  Comparison of angioplasty with stenting, with or without abciximab, in acute myocardial infarction. , 2002, The New England journal of medicine.