Automatic Annotation of Retinal Layers in Optical Coherence Tomography Images

Early diagnosis of retinal OCT images has been shown to curtail blindness and visual impairments. However, the advancement of ophthalmic imaging technologies produces an ever-growing scale of retina images, both in volume and variety, which overwhelms the ophthalmologist ability to segment these images. While many automated methods exist, speckle noise and intensity inhomogeneity negatively impacts the performance of these methods. We present a comprehensive and fully automatic method for annotation of retinal layers in OCT images comprising of fuzzy histogram hyperbolisation (FHH) and graph cut methods to segment 7 retinal layers across 8 boundaries. The FHH handles speckle noise and inhomogeneity in the preprocessing step. Then the normalised vertical image gradient, and it’s inverse to represent image intensity in calculating two adjacency matrices and then the FHH reassigns the edge-weights to make edges along retinal boundaries have a low cost, and graph cut method identifies the shortest-paths (layer boundaries). The method is evaluated on 150 B-Scan images, 50 each from the temporal, foveal and nasal regions were used in our study. Promising experimental results have been achieved with high tolerance and adaptability to contour variance and pathological inconsistency of the retinal layers in all (temporal, foveal and nasal) regions. The method also achieves high accuracy, sensitivity, and Dice score of 0.98360, 0.9692 and 0.9712, respectively in segmenting the retinal nerve fibre layer. The annotation can facilitate eye examination by providing accurate results. The integration of the vertical gradients into the graph cut framework, which captures the unique characteristics of retinal structures, is particularly useful in finding the actual minimum paths across multiple retinal layer boundaries. Prior knowledge plays an integral role in image segmentation.

[1]  Xiaohui Liu,et al.  Retinal OCT Image Segmentation Using Fuzzy Histogram Hyperbolization and Continuous Max-Flow , 2017, 2017 IEEE 30th International Symposium on Computer-Based Medical Systems (CBMS).

[2]  Xiaohui Liu,et al.  Retinal blood vessel segmentation via graph cut , 2010, 2010 11th International Conference on Control Automation Robotics & Vision.

[3]  Ronald Klein,et al.  The prevalence of age-related eye diseases and visual impairment in aging: current estimates. , 2013, Investigative ophthalmology & visual science.

[4]  V. Magudeeswaran,et al.  Fuzzy Logic-Based Histogram Equalization for Image Contrast Enhancement , 2013 .

[5]  Carmen A Puliafito,et al.  Automated detection of retinal layer structures on optical coherence tomography images. , 2005, Optics express.

[6]  A. Fercher,et al.  In vivo human retinal imaging by Fourier domain optical coherence tomography. , 2002, Journal of biomedical optics.

[7]  Xiaohui Liu,et al.  Graph-Cut Segmentation of Retinal Layers from OCT Images , 2018, BIOIMAGING.

[8]  Yan Lindsay Sun,et al.  Automated layer segmentation of optical coherence tomography images , 2011, 2011 4th International Conference on Biomedical Engineering and Informatics (BMEI).

[9]  Xiaodong Wu,et al.  Automated 3-D Intraretinal Layer Segmentation of Macular Spectral-Domain Optical Coherence Tomography Images , 2009, IEEE Transactions on Medical Imaging.

[10]  S. Rajaram,et al.  Big Data in Medical Image Processing , 2018 .

[11]  X Liu,et al.  Retina layer segmentation using kernel graph cuts and continuous max-flow. , 2015, Optics express.

[12]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[13]  Xiaohui Liu,et al.  Segmentation of Retinal Blood Vessels Using Gaussian Mixture Models and Expectation Maximisation , 2013, HIS.

[14]  Alexander Wong,et al.  Intra-retinal layer segmentation in optical coherence tomography images. , 2009, Optics express.

[15]  Kim L. Boyer,et al.  Automatic recovery of the optic nervehead geometry in optical coherence tomography , 2006, IEEE Transactions on Medical Imaging.

[16]  Xiaohui Liu,et al.  Level Set Segmentation of Retinal OCT Images , 2019, BIOIMAGING.

[17]  Chuang Wang,et al.  Level Set Segmentation of Optic Discs from Retinal Images , 2015 .

[18]  H. M. Salinas,et al.  Comparison of PDE-Based Nonlinear Diffusion Approaches for Image Enhancement and Denoising in Optical Coherence Tomography , 2007, IEEE Transactions on Medical Imaging.

[19]  Milan Sonka,et al.  Curvature correction of retinal OCTs using graph-based geometry detection , 2013, Physics in medicine and biology.

[20]  Hamid R. Tizhoosh,et al.  Fuzzy Image Processing: Potentials and State of the Art , 1998 .

[21]  Shijian Lu,et al.  Automated layer segmentation of optical coherence tomography images , 2010, 2010 5th IEEE Conference on Industrial Electronics and Applications.

[22]  Kim L. Boyer,et al.  Retinal thickness measurements from optical coherence tomography using a Markov boundary model , 2001, IEEE Transactions on Medical Imaging.

[23]  Delia Cabrera Fernandez,et al.  Delineating fluid-filled region boundaries in optical coherence tomography images of the retina , 2005, IEEE Transactions on Medical Imaging.

[24]  Hamid R. Tizhoosh,et al.  Fuzzy image enhancement and associative feature matching in radiotherapy , 1997, Proceedings of International Conference on Neural Networks (ICNN'97).

[25]  Hamid R. Tizhoosh,et al.  Locally Adaptive Fuzzy Image Enhancement , 1997, Fuzzy Days.

[26]  Yongmin Li,et al.  MRF Reconstruction of Retinal Images for the Optic Disc Segmentation , 2012, HIS.

[27]  Gábor Márk Somfai,et al.  Real-Time Automatic Segmentation of Optical Coherence Tomography Volume Data of the Macular Region , 2015, PloS one.

[28]  Zidong Wang,et al.  Segmentation of Intra-retinal Layers in 3D Optic Nerve Head Images , 2015, ICIG.

[29]  Xiaodong Wu,et al.  Incorporation of Regional Information in Optimal 3-D Graph Search with Application for Intraretinal Layer Segmentation of Optical Coherence Tomography Images , 2007, IPMI.

[30]  Jürgen Weese,et al.  Four challenges in medical image analysis from an industrial perspective , 2016, Medical Image Anal..

[31]  Xiaohui Liu,et al.  Segmentation of the Blood Vessels and Optic Disk in Retinal Images , 2014, IEEE Journal of Biomedical and Health Informatics.

[32]  Jerry L Prince,et al.  Retinal layer segmentation of macular OCT images using boundary classification , 2013, Biomedical optics express.

[33]  Xiaohui Liu,et al.  Automatic graph cut based segmentation of retinal optic disc by incorporating blood vessel compensation. , 2012, SOCO 2012.

[34]  Xiaohui Liu,et al.  Optic disc segmentation by incorporating blood vessel compensation , 2011, 2011 IEEE Third International Workshop On Computational Intelligence In Medical Imaging.

[35]  Allan Tucker,et al.  Retinal OCT Segmentation Using Fuzzy Region Competition and Level Set Methods , 2019, 2019 IEEE 32nd International Symposium on Computer-Based Medical Systems (CBMS).

[36]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[37]  B. Bouma,et al.  Speckle reduction in optical coherence tomography by "path length encoded" angular compounding. , 2003, Journal of biomedical optics.

[38]  Jelena Novosel,et al.  Loosely coupled level sets for retinal layer segmentation in optical coherence tomography , 2013, 2013 IEEE 10th International Symposium on Biomedical Imaging.

[39]  Xiaohui Liu,et al.  Retinal blood vessels extraction using probabilistic modelling , 2014, Health Information Science and Systems.

[40]  M. Baroni,et al.  Towards quantitative analysis of retinal features in optical coherence tomography. , 2007, Medical engineering & physics.

[41]  Giovanni Gregori,et al.  A Robust Algorithm for Retinal Thickness Measurements using Optical Coherence Tomography (Stratus OCT) , 2004 .

[42]  Ya Xing Wang,et al.  Automatic Choroidal Layer Segmentation Using Markov Random Field and Level Set Method , 2017, IEEE Journal of Biomedical and Health Informatics.

[43]  Andrew M. Rollins,et al.  3-D Stent Detection in Intravascular OCT Using a Bayesian Network and Graph Search , 2015, IEEE Transactions on Medical Imaging.

[44]  J. Hornegger,et al.  Retinal Nerve Fiber Layer Segmentation on FD-OCT Scans of Normal Subjects and Glaucoma Patients , 2010, Biomedical optics express.

[45]  Joseph A. Izatt,et al.  Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation , 2010, Optics express.

[46]  B. Aisbett,et al.  Sleep Restriction during Simulated Wildfire Suppression: Effect on Physical Task Performance , 2015, PloS one.

[47]  Zidong Wang,et al.  Automated Layer Segmentation of 3D Macular Images Using Hybrid Methods , 2015, ICIG.

[48]  A. Fercher,et al.  Speckle reduction in optical coherence tomography by frequency compounding. , 2003, Journal of biomedical optics.

[49]  Edsger W. Dijkstra,et al.  A note on two problems in connexion with graphs , 1959, Numerische Mathematik.