Performance comparison of wind park configurations

In this report, layouts of various large-scale wind parks, both AC as well as DC, are investigated. Loss modelling of the wind park components as well as calculations of the energy capture of the turbines using various electrical systems are performed, and the energy production cost of the various park configurations is determined. It was found that from an energy capture point of view, the difference in energy production between various wind turbine systems is very small. In addition, a study of the suitability of various DC/DC-converters is made. Three DC/DC-converters, Boost, Full Bridge and Full Bridge Isolated Boost, are found to be interesting candidates as the "transformer" component in potential DC-based wind parks. Of all the investigated wind park configurations, the wind park with the series connected DC wind turbines seems to have the best potential to give the lowest energy production cost, if the transmission distance is longer then 10-20km.

[1]  Fred C. Lee,et al.  Isolated boost circuit for power factor correction , 1993, Proceedings Eighth Annual Applied Power Electronics Conference and Exposition,.

[2]  Mohamed Mohandes,et al.  Wind power cost assessment at twenty locations in the kingdom of Saudi Arabia , 2003 .

[3]  G. L. Johnson,et al.  Wind energy systems , 1985 .

[4]  Torbjorn Thiringer,et al.  Modeling of Wind Turbines for Power System Studies , 2002, IEEE Power Engineering Review.

[5]  F. Abrahamsen CHAPTER 6 – Energy Optimal Control of Induction Motor Drives , 2000 .

[6]  Stefan Lundberg Electrical limiting factors for wind energy installations , 2000 .

[7]  P. D. Evans,et al.  Analysis of on-state losses in PWM inverters , 1989 .

[8]  Stefan Lundberg,et al.  Electrical limiting Factors for Wind Energy Installations in Weak Grids , 2001 .

[9]  L. Weimers New markets need new technology , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[10]  Peter J. Wolfs A current-sourced DC-DC converter derived via the duality principle from the half-bridge converter , 1993, IEEE Trans. Ind. Electron..

[11]  Anders Grauers,et al.  Design of Direct-driven Permanent-magnet Generators for Wind Turbines , 1996 .

[12]  F. Blaabjerg,et al.  An extended model of power losses in hard-switched IGBT-inverters , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[13]  Arne Hejde Nielsen,et al.  Advanced simulation of windmills in the electric power supply , 2000 .

[14]  Birgitte Bak-Jensen,et al.  Conceptual survey of Generators and Power Electronics for Wind Turbines , 2001 .

[15]  Frede Blaabjerg,et al.  Power losses in PWM-VSI inverter using NPT or PT IGBT devices , 1994 .