Enhanced methodology of focus control and monitoring on scanner tool

As the demand of the technology node shrinks from 14nm to 7nm, the reliability of tool monitoring techniques in advanced semiconductor fabs to achieve high yield and quality becomes more critical. Tool health monitoring methods involve periodic sampling of moderately processed test wafers to detect for particles, defects, and tool stability in order to ensure proper tool health. For lithography TWINSCAN scanner tools, the requirements for overlay stability and focus control are very strict. Current scanner tool health monitoring methods include running BaseLiner to ensure proper tool stability on a periodic basis. The focus measurement on YIELDSTAR by real-time or library-based reconstruction of critical dimensions (CD) and side wall angle (SWA) has been demonstrated as an accurate metrology input to the control loop. The high accuracy and repeatability of the YIELDSTAR focus measurement provides a common reference of scanner setup and user process. In order to further improve the metrology and matching performance, Diffraction Based Focus (DBF) metrology enabling accurate, fast, and non-destructive focus acquisition, has been successfully utilized for focus monitoring/control of TWINSCAN NXT immersion scanners. The optimal DBF target was determined to have minimized dose crosstalk, dynamic precision, set-get residual, and lens aberration sensitivity. By exploiting this new measurement target design, ~80% improvement in tool-to-tool matching, >16% improvement in run-to-run mean focus stability, and >32% improvement in focus uniformity have been demonstrated compared to the previous BaseLiner methodology. Matching <2.4 nm across multiple NXT immersion scanners has been achieved with the new methodology of set baseline reference. This baseline technique, with either conventional BaseLiner low numerical aperture (NA=1.20) mode or advanced illumination high NA mode (NA=1.35), has also been evaluated to have consistent performance. This enhanced methodology of focus control and monitoring on multiple illumination conditions, opens an avenue to significantly reduce Focus-Exposure Matrix (FEM) wafer exposure for new product/layer best focus (BF) setup.

[1]  Peter Vanoppen,et al.  Lithographic scanner stability improvements through advanced metrology and control , 2010, Advanced Lithography.

[2]  Ye Tian,et al.  Focus control enhancement and on-product focus response analysis methodology , 2016, SPIE Advanced Lithography.

[3]  Chen Li,et al.  Applications of on-product diffraction-based focus metrology in logic high volume manufacturing , 2016, SPIE Advanced Lithography.

[4]  Kaustuve Bhattacharyya,et al.  YieldStar: a new metrology platform for advanced lithography control , 2011, European Mask and Lithography Conference.

[5]  Young Seog Kang,et al.  Improvement of inter-field CDU by using on-product focus control , 2014, Advanced Lithography.

[6]  Frank Staals,et al.  Improving focus performance at litho using diffraction-based focus metrology, novel calibration methods, interface, and control loop , 2016, SPIE Advanced Lithography.

[7]  M. Ebert,et al.  New approaches in diffraction based optical metrology , 2016, SPIE Advanced Lithography.

[8]  Michael Kubis,et al.  Combined overlay, focus and CD metrology for leading edge lithography , 2011, Advanced Lithography.

[9]  Reinder Plug,et al.  Improving on-product performance at litho using integrated diffraction-based metrology and computationally designed device-like targets fit for advanced technologies (incl. FinFET) , 2014, Advanced Lithography.

[10]  Bart Segers,et al.  Intra-field patterning control using high-speed and small-target optical metrology of CD and focus , 2015, Advanced Lithography.