An Adaptive Control System for Three-Phase Photovoltaic Inverters Working in a Polluted and Variable Frequency Electric Grid

The proportional + resonant (PR) controller has been proposed in the past as a suitable method to control the current generated by the grid-connected photovoltaic voltage source inverters. Due to the fact that information regarding the frequency of the grid is needed to use this control technique, the synchronous reference frame phase-locked loop (SRF-PLL) is commonly used. To assure that the total harmonic distortion of the injected current (THDi) meets the appropriate standards, even if the grid voltage is polluted and its frequency varies, an adaptive control strategy is presented in this paper. This control strategy can improve the behavior of both, the conventional SRF-PLL and the conventional PR controller, when they are used in a polluted grid with a time varying frequency. The experimental results obtained by means of a digitally controlled 10-kVA inverter, show up that the THDi of the injected current is improved when the proposed adaptive control strategy replaces the conventional one.

[1]  Phillip A. Regalia,et al.  Stable and efficient lattice algorithms for adaptive IIR filtering , 1992, IEEE Trans. Signal Process..

[2]  K.. De Brabandere,et al.  A Voltage and Frequency Droop Control Method for Parallel Inverters , 2007, IEEE Transactions on Power Electronics.

[3]  V. Blasko,et al.  A new mathematical model and control of a three-phase AC-DC voltage source converter , 1997 .

[4]  P. Regalia Adaptive IIR Filtering in Signal Processing and Control , 1994 .

[5]  Daljit K. Mehra,et al.  Tracking of time-varying channels using two-step LMS-type adaptive algorithm , 2006, IEEE Transactions on Signal Processing.

[6]  V. Blasko,et al.  A Novel Method for Selective Harmonic Elimination in Power Electronic Equipment , 2007, IEEE Transactions on Power Electronics.

[7]  K. Mauch,et al.  Parallel operation of single phase inverter modules with no control interconnections , 1997, Proceedings of APEC 97 - Applied Power Electronics Conference.

[8]  A. G. Yepes,et al.  Three-Phase PLLs With Fast Postfault Retracking and Steady-State Rejection of Voltage Unbalance and Harmonics by Means of Lead Compensation , 2011, IEEE Transactions on Power Electronics.

[9]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[10]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[11]  Juan C. Vasquez,et al.  Hierarchical Control of Droop-Controlled AC and DC Microgrids—A General Approach Toward Standardization , 2009, IEEE Transactions on Industrial Electronics.

[12]  Paolo Mattavelli,et al.  Synchronous-frame harmonic control for high-performance AC power supplies , 2001 .

[13]  F. Blaabjerg,et al.  Distributed Generation: Toward a New Energy Paradigm , 2010, IEEE Industrial Electronics Magazine.

[14]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[15]  Jiabing Hu,et al.  Modeling and Control of Grid-Connected Voltage-Sourced Converters Under Generalized Unbalanced Operation Conditions , 2008, IEEE Transactions on Energy Conversion.

[16]  P. Vaidyanathan,et al.  A unified structural interpretation of some well-known stability-test procedures for linear systems , 1987, Proceedings of the IEEE.

[17]  Bruce A. Francis,et al.  The internal model principle of control theory , 1976, Autom..

[18]  Lisheng Shi,et al.  A novel PLL system based on adaptive resonant filter , 2008, 2008 40th North American Power Symposium.

[19]  J. Doval-Gandoy,et al.  Tuning of Phase-Locked Loops for Power Converters Under Distorted Utility Conditions , 2009, IEEE Transactions on Industry Applications.

[20]  S. Haykin,et al.  Adaptive Filter Theory , 1986 .

[21]  K. Nam,et al.  An instantaneous phase angle detection algorithm under unbalanced line voltage condition , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[22]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.

[23]  Hossin Hosseinian,et al.  Power Electronics , 2020, 2020 27th International Conference on Mixed Design of Integrated Circuits and System (MIXDES).

[24]  S. Maestri,et al.  Variable Sampling Period Filter PLL for Distorted Three-Phase Systems , 2012, IEEE Transactions on Power Electronics.

[25]  M. Liserre,et al.  A Comparative Analysis of Real-Time Algorithms for Power Signal Decomposition in Multiple Synchronous Reference Frames , 2007, IEEE Transactions on Power Electronics.

[26]  M. Liserre,et al.  Evaluation of Current Controllers for Distributed Power Generation Systems , 2009, IEEE Transactions on Power Electronics.

[27]  Guan-Chyun Hsieh,et al.  Phase-locked loop techniques. A survey , 1996, IEEE Trans. Ind. Electron..

[28]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[29]  F. Blaabjerg,et al.  Adaptive resonant controller for grid-connected converters in distributed power generation systems , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[30]  D. G. Holmes,et al.  Frequency domain analysis of three phase linear current regulators , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[31]  Gabriel Garcerá,et al.  An Adaptive Synchronous-Reference-Frame Phase-Locked Loop for Power Quality Improvement in a Polluted Utility Grid , 2012, IEEE Transactions on Industrial Electronics.