Design and fully digital control of parallel active filters for thyristor rectifiers

The paper presents the implementation of a digitally controlled parallel active filter for a thyristor rectifier with inductive load. Using a state-of-the-art DSP platform (ADSP21020 and ADMC200), a fully digital control of the system, based on the dead-beat control of inverter currents and space vector modulation, is implemented. The intrinsic calculation delay of the dead-beat algorithm is shown to represent a serious hurdle for the achievement of a satisfactory compensation quality. In particular, meeting the IEC 1000-3-2 standards for class A equipment appears to be quite difficult especially in the high frequency range. The paper investigates the effects of the input passive filters and power converter design on the system's performance and describes the implementation of the digital control by means of the specified hardware. Experimental results are finally given to evaluate the achieved performance.

[1]  Atsuo Kawamura,et al.  Dead beat microprocessor control of PWM inverter for sinusoidal output waveform synthesis , 1985 .

[2]  Donald Grahame Holmes,et al.  Implementation of a direct digital predictive current controller for single and three phase voltage source inverters , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[3]  Y. Sato,et al.  A current type PWM rectifier with active damping function , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[4]  Thomas G. Habetler,et al.  A space vector-based rectifier regulator for AC/DC/AC converters , 1993 .

[5]  Takao Kawabata,et al.  Dead beat control of three phase PWM inverter , 1987 .

[6]  Hirofumi Akagi,et al.  Control Strategy of Active Power Filters Using Multiple Voltage-Source PWM Converters , 1986, IEEE Transactions on Industry Applications.

[7]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three phase voltage source converter , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[8]  Bikramjit Banerjee,et al.  Parallel active filter system implementation and design issues for utility interface of adjustable speed drive systems , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[9]  H. Akagi,et al.  Analysis and design of an active power filter using quad-series voltage source PWM converters , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[10]  Paolo Mattavelli,et al.  High-performance hysteresis modulation technique for active filters , 1997 .

[11]  L. Malesani,et al.  Active filter for reactive power and harmonics compensation , 1986, 1986 17th Annual IEEE Power Electronics Specialists Conference.

[12]  Donald Grahame Holmes,et al.  A simple, novel method for variable-hysteresis-band current control of a three phase inverter with constant switching frequency , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[13]  Atsuo Kawamura,et al.  Deadbeat controlled PWM inverter with parameter estimation using only voltage sensor , 1988, 1986 17th Annual IEEE Power Electronics Specialists Conference.