Bayesian framework for artifact reduction on ECG IN MRI

Electrocardiogram (ECG) is required during Magnetic Resonance Imaging (MRI) for two reasons, patient monitoring and MRI sequence synchronization for cardiovascular imaging. The MRI environment severely distorts ECG signals. The Magnetic Field Gradients (MFG) especially induce artifacts, which make ECG analysis during MRI acquisition challenging. Specific signal processing is thus required. An MFG artifact modeling has been proposed for their suppression. However the resulting techniques do not take the ECG signals into account during the model parameter estimation. Recently, ECG denoising based on an artificial ECG model and nonlinear Bayesian filtering has been presented. In this paper, a new MFG artifact suppression method based on nonlinear Bayesian filtering and the unification of the ECG and MFG models is proposed. This new approach enables accurate patient monitoring and outperforms state-of-the-art methods in terms of both QRS detection quality and signal to noise ratio.

[1]  F. Shellock,et al.  MR procedures: biologic effects, safety, and patient care. , 2004, Radiology.

[2]  Mohammad Bagher Shamsollahi,et al.  ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure , 2008, IEEE Transactions on Biomedical Engineering.

[3]  J. Felblinger,et al.  Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates , 2004, Magnetic Resonance Materials in Physics, Biology and Medicine.

[4]  R. Kreis,et al.  Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences , 1999, Magnetic resonance in medicine.

[5]  Olivier Pietquin,et al.  A specific QRS detector for electrocardiography during MRI: Using wavelets and local regularity characterization , 2009, 2009 IEEE International Conference on Acoustics, Speech and Signal Processing.

[6]  C H Lorenz,et al.  Novel real‐time R‐wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions , 1999, Magnetic resonance in medicine.

[7]  Roger Abächerli,et al.  Noise Cancellation Signal Processing Method and Computer System for Improved Real-Time Electrocardiogram Artifact Correction During MRI Data Acquisition , 2007, IEEE Transactions on Biomedical Engineering.

[8]  Patrick E. McSharry,et al.  A dynamical model for generating synthetic electrocardiogram signals , 2003, IEEE Transactions on Biomedical Engineering.

[9]  Olivier Pietquin,et al.  Adaptive RR prediction for cardiac MRI , 2008, 2008 IEEE International Conference on Acoustics, Speech and Signal Processing.

[10]  D. Firmin,et al.  Motion in cardiovascular MR imaging. , 2009, Radiology.

[11]  Christian Jutten,et al.  A Nonlinear Bayesian Filtering Framework for ECG Denoising , 2007, IEEE Transactions on Biomedical Engineering.