Radiochromic film diagnostics for laser-driven ion beams

Radiochromic film (RCF) based multichannel diagnostics utilizes the concept of a stack detector comprised of alternating layers of RCFs and shielding aluminium layers. An algorithm based on SRIM simulations is used to correct the accumulated dose. Among the standard information that can be obtained is the maximum ion energy and to some extend the beam energy spectrum. The main area where this detector shines though is the geometrical characterization of the beam. Whereas other detectors such as Thomson parabola spectrometer or Faraday cups detect only a fraction of the outburst cone, the RCF stack placed right behind the target absorbs the whole beam. A complete 2D and to some extend 3D imprint of the ion beam allows us to determine parameters such as divergence or beam center shift with respect to the target normal. The obvious drawback of such diagnostics is its invasive character. But considering that only a few successful shots (2-3) are needed per one kind of target to perform the analysis, the drawbacks are acceptable. In this work, we present results obtained with the RCF diagnostics using both conventional accelerators and laser-driven ion beams during 2 experimental campaigns.

[1]  M. G. Sabini,et al.  A 62 MeV proton beam for the treatment of ocular melanoma at Laboratori Nazionali del Sud-INFN (CATANIA) , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[2]  Michael D. Perry,et al.  Electron, photon, and ion beams from the relativistic interaction of Petawatt laser pulses with solid targets , 2000 .

[3]  Wolfgang Enghardt,et al.  High proton energies from cone targets: electron acceleration mechanisms , 2012 .

[4]  H. Daido,et al.  Review of laser-driven ion sources and their applications , 2012, Reports on progress in physics. Physical Society.

[5]  J. Ziegler,et al.  SRIM – The stopping and range of ions in matter (2010) , 2010 .

[6]  T E Cowan,et al.  Development and first experimental tests of Faraday cup array. , 2014, The Review of scientific instruments.

[7]  K. Flippo,et al.  Radiochromic film imaging spectroscopy of laser-accelerated proton beams. , 2009, The Review of scientific instruments.

[8]  M. G. Sabini,et al.  A 62-MeV proton beam for the treatment of ocular melanoma at Laboratori Nazionali del Sud-INFN , 2004, IEEE Transactions on Nuclear Science.

[9]  Lu Zhang,et al.  A study of dosimetry characteristics of GAF DM-1260 radiochromic films , 2000 .

[10]  R R Freeman,et al.  Use of GafChromic film to diagnose laser generated proton beams. , 2008, The Review of scientific instruments.

[11]  David Parker,et al.  Radiochromic film spectroscopy of laser-accelerated proton beams using the FLUKA code and dosimetry traceable to primary standards , 2011 .

[12]  Marco Borghesi,et al.  A new algorithm for spectral and spatial reconstruction of proton beams from dosimetric measurements , 2004 .

[13]  Tae Moon Jeong,et al.  Femtosecond petawatt laser , 2014 .

[14]  T. C. Sangster,et al.  Intense high-energy proton beams from Petawatt-laser irradiation of solids. , 2000, Physical review letters.