Conception of an integrated sensor for the radiation monitoring of the CMS experiment at the large hadron collider

The concept of an active integrated dosimetric sensor for the radiation monitoring of the Compact Muon Solenoid experiment at the CERN (European Center for Nuclear Research) Large Hadron Collider is presented. The sensor, based on RadFET, OSL, p-i-n diode, and pad detector dosimeters, will measure both ionizing and nonionizing energy losses in the harsh radiation environment produced by hadron interactions.

[1]  Michael Moll,et al.  Relation between microscopic defects and macroscopic changes in silicon detector properties after hadron irradiation , 2002 .

[2]  M. Huhtinen,et al.  European Laboratory for Particle Physics Radiation Environment Simulations for the Cms Detector Radiation Environment Simulations for the Cms Detector , 2022 .

[3]  Eckhart Fretwurst,et al.  Leakage current of hadron irradiated silicon detectors - material dependence , 1999 .

[4]  A. H. Sullivan,et al.  A Guide to radiation and radioactivity levels near high energy particle accelerators , 1992 .

[5]  C. Leroy,et al.  New irradiation zones at the CERN-PS , 1999 .

[6]  Andrew Holmes-Siedle,et al.  Handbook of Radiation Effects , 1993 .

[7]  G. Paic,et al.  Comparison of high-dose dosimetry systems for radiation damage studies in collider detectors and accelerators , 1993 .

[8]  M. Glaser,et al.  A study on the applicability of solid state, real-time dosimeters to the CMS experiment at the large hadron collider , 2003 .

[10]  A. Rosenfeld,et al.  P-I-N Diodes with a Wide Measurement Range of Fast Neutron Doses , 1990 .

[11]  G. Sarrabayrouse,et al.  MOS ionizing radiation dosimeters: from low to high dose measurement , 2001 .

[12]  A. Holmes-Siedle,et al.  The Dose mapping system for the electromagnetic calorimeter of the BaBar experiment at SLAC , 2001 .

[13]  W. Lane,et al.  Electrical performance and radiation sensitivity of stacked PMOS dosimeters under bulkbias control , 1998 .

[14]  R. L. Pease,et al.  Comparison of pMOSFET total dose response for Co-60 gammas and high-energy protons , 2001 .

[15]  L. Adams,et al.  RADFET: A review of the use of metal-oxide-silicon devices as integrating dosimeters , 1986 .

[16]  Robert Ecoffet,et al.  Characterization of an integrated sensor using optically stimulated luminescence for in-flight dosimetry , 2002 .

[17]  G. Brucker,et al.  The use of hydrogenous material for sensitizing pMOS dosimeters to neutrons , 1995 .

[18]  F. Ravotti,et al.  Optically stimulated luminescence materials for wide-spectrum neutron measurements at CERN , 2005, IEEE Transactions on Nuclear Science.

[19]  Robert Ecoffet,et al.  Hardening of a radiation sensor based on optically stimulated luminescence , 2003 .

[20]  H. Kraner,et al.  Effects of fast neutron radiation on the electrical properties of silicon detectors , 1991 .