Evaluation of radiofrequency catheter ablation settings for variable atrial tissue depth and flow conditions

Catheter ablation (CA) is a potentially curative therapy for paroxysmal atrial fibrillation, however up to 50%b of patients may require a repeat procedure to achieve the best results. While this may be due to insufficient radiofrequency (RF) energy delivery to achieve transmural, contiguous ablation lesions (TAL), excessive RF application may result in extracardiac injury and complications. We aim to evaluate optimal RFCA temperature settings for variable atrial tissue depth and blood flow conditions. Heat spread in atrial tissue and blood was simulated using the Pennes bioheat equation with an additional convective term in the blood. The minimum catheter contact time required for TAL formation increased with increasing either atrial wall thickness (AWT) or laminar flow velocity (LFV). Thus, during ablation of atrial tissue regions with AWT of 1 and 5.5 mm andLFVof0.1 m/s, TALs were formed in 12 and 153 s, respectively. When LFV was increased to 1.2 m/s, the TAL formation time increased to 21 and 174 s. The maximum temperature in the blood volume stayed below the coagulation risk threshold of 70°Cfor all AWT values with LFVs over 0.6 m/s, but raised above the threshold for LFV ≤ 0.6 m/s and AWT > 1.5 mm. This study demonstrates the potential for optimizing RFCA settings according to atrial tissue depth and flow, which may improve the efficacy of RFCA therapy.

[1]  Fred H M Wittkampf,et al.  RF Catheter Ablation: Lessons on Lesions , 2006, Pacing and clinical electrophysiology : PACE.

[2]  W. Saliba,et al.  Catheter ablation for atrial fibrillation. , 2011, The New England journal of medicine.

[3]  B. Hoit,et al.  Left atrial size and function: role in prognosis. , 2014, Journal of the American College of Cardiology.

[4]  Graeme P. Penney,et al.  A novel methodology for personalized simulations of ventricular hemodynamics from noninvasive imaging data , 2016, Comput. Medical Imaging Graph..

[5]  Benoit Desjardins,et al.  Effect of left atrial circumferential ablation for atrial fibrillation on left atrial transport function. , 2005, Heart rhythm.

[6]  Francis A. Duck,et al.  Thermal Properties of Tissue , 1990 .

[7]  Ana González-Suárez,et al.  Comparative Analysis of Different Methods of Modeling the Thermal Effect of Circulating Blood Flow During RF Cardiac Ablation , 2016, IEEE Transactions on Biomedical Engineering.

[8]  G. Paxinos,et al.  Clinical outcome of left atrial ablation for paroxysmal atrial fibrillation is related to the extent of radiofrequency ablation , 2008, Journal of Interventional Cardiac Electrophysiology.

[9]  D. Haines,et al.  Effect of Heating on Pulmonary Veins: , 2003, Journal of cardiovascular electrophysiology.

[10]  Hong Cao,et al.  Flow effect on lesion formation in RF cardiac catheter ablation , 2001, IEEE Transactions on Biomedical Engineering.

[11]  Elia Biganzoli,et al.  Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation , 2005, Circulation. Arrhythmia and electrophysiology.

[12]  Markus Henningsson,et al.  Novel MRI Technique Enables Non-Invasive Measurement of Atrial Wall Thickness , 2017, IEEE Transactions on Medical Imaging.

[13]  Hong Cao,et al.  Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablation , 2001, IEEE Transactions on Biomedical Engineering.

[14]  G. Seemann,et al.  Slow Conduction in the Border Zones of Patchy Fibrosis Stabilizes the Drivers for Atrial Fibrillation: Insights from Multi-Scale Human Atrial Modeling , 2016, Front. Physiol..

[15]  Gerhard Hindricks,et al.  2012 Focused Update of the ESC Guidelines for the Management of Atrial Fibrillation , 2013 .