Dynamic PET image reconstruction incorporating a median nonlocal means kernel method

In dynamic positron emission tomography (PET) imaging, the reconstructed image of a single frame often exhibits high noise due to limited counting statistics of projection data. This study proposed a median nonlocal means (MNLM)-based kernel method for dynamic PET image reconstruction. The kernel matrix is derived from median nonlocal means of pre-reconstructed composite images. Then the PET image intensities in all voxels were modeled as a kernel matrix multiplied by coefficients and incorporated into the forward model of PET projection data. Then, the coefficients of each feature were estimated by the maximum likelihood method. Using simulated low-count dynamic data of Zubal head phantom, the quantitative performance of the proposed MNLM kernel method was investigated and compared with the maximum-likelihood method, conventional kernel method with and without median filter, and nonlocal means (NLM) kernel method. Simulation results showed that the MNLM kernel method achieved visual and quantitative accuracy improvements (in terms of the ensemble mean squared error, bias versus variance, and contrast versus noise performances). Especially for frame 2 with the lowest count level of a single frame, the MNLM kernel method achieves lower ensemble mean squared error (10.43%) than the NLM kernel method (13.68%), conventional kernel method with and without median filter (11.88% and 23.50%), and MLEM algorithm (24.77%). The study on real low-dose 18F-FDG rat data also showed that the MNLM kernel method outperformed other methods in visual and quantitative accuracy improvements (in terms of regional noise versus intensity mean performance).

[1]  J. Bowsher,et al.  Utilizing MRI information to estimate F18-FDG distributions in rat flank tumors , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[2]  Guobao Wang,et al.  Acceleration of the direct reconstruction of linear parametric images using nested algorithms , 2010, Physics in medicine and biology.

[3]  Richard M. Leahy,et al.  Statistical approaches in quantitative positron emission tomography , 2000, Stat. Comput..

[4]  Guobao Wang,et al.  Dynamic PET Image reconstruction for parametric imaging using the HYPR kernel method , 2017, Medical Imaging.

[5]  Ji Eun Jung,et al.  Non-local Weighted Median Regularization for PET Reconstruction , 2018, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).

[6]  Chung Chan,et al.  Postreconstruction Nonlocal Means Filtering of Whole-Body PET With an Anatomical Prior , 2014, IEEE Transactions on Medical Imaging.

[7]  Simon R. Arridge,et al.  PET Image Reconstruction Using Information Theoretic Anatomical Priors , 2011, IEEE Transactions on Medical Imaging.

[8]  Qian He,et al.  Penalized Maximum Likelihood Algorithm for Positron Emission Tomography by Using Anisotropic Median-Diffusion , 2014 .

[9]  M. Bergström,et al.  11C-metomidate PET imaging of adrenocortical cancer , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[10]  Marvin Bergsneider,et al.  Optimal design in dynamic PET data acquisition: a new approach using simulated annealing and component-wise Metropolis updating , 2001 .

[11]  Guobao Wang,et al.  Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity , 2018, IEEE Transactions on Medical Imaging.

[12]  Pawel Markiewicz,et al.  PET Reconstruction With an Anatomical MRI Prior Using Parallel Level Sets , 2016, IEEE Transactions on Medical Imaging.

[13]  John J. Lee,et al.  Cerebrovascular occlusive disease: quantitative cerebral blood flow using dynamic susceptibility contrast mr imaging correlates with quantitative H2[15O] PET. , 2013, Radiology.

[14]  Michal Irani,et al.  Internal statistics of a single natural image , 2011, CVPR 2011.

[15]  Charles A Mistretta,et al.  Dynamic PET Denoising with HYPR Processing , 2010, Journal of Nuclear Medicine.

[16]  R. Leahy,et al.  Magnetic resonance-guided positron emission tomography image reconstruction. , 2013, Seminars in nuclear medicine.

[17]  Charles A Mistretta,et al.  Improved kinetic analysis of dynamic PET data with optimized HYPR-LR. , 2012, Medical physics.

[18]  Philip Novosad,et al.  MR-guided dynamic PET reconstruction with the kernel method and spectral temporal basis functions , 2016, Physics in medicine and biology.

[19]  Jeffrey A. Fessler,et al.  Non-local means methods using CT side information for I-131 SPECT image reconstruction , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[20]  Habib Zaidi,et al.  Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation–maximization reconstruction , 2016, Physics in medicine and biology.

[21]  Paul Kinahan,et al.  Analytic 3D image reconstruction using all detected events , 1989 .

[22]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[23]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[24]  Soo-Jin Lee,et al.  Incorporating Anatomical Side Information Into PET Reconstruction Using Nonlocal Regularization , 2013, IEEE Transactions on Image Processing.

[25]  Steven Meikle,et al.  Regularized image reconstruction with an anatomically adaptive prior for positron emission tomography. , 2009, Physics in medicine and biology.

[26]  Leyun Pan,et al.  Parametric imaging: a promising approach for the evaluation of dynamic PET-18F-FDG studies - the DKFZ experience. , 2010, Hellenic journal of nuclear medicine.

[27]  Guobao Wang,et al.  Generalized Algorithms for Direct Reconstruction of Parametric Images From Dynamic PET Data , 2009, IEEE Transactions on Medical Imaging.

[28]  Jun Yu,et al.  Median-prior tomography reconstruction combined with nonlinear anisotropic diffusion filtering. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[29]  Guobao Wang,et al.  Anatomically-aided PET reconstruction using the kernel method , 2016, Physics in medicine and biology.

[30]  Anthonin Reilhac,et al.  Evaluation of Three MRI-Based Anatomical Priors for Quantitative PET Brain Imaging , 2012, IEEE Transactions on Medical Imaging.

[31]  Jinyi Qi,et al.  PET image reconstruction with anatomical edge guided level set prior , 2011, Physics in medicine and biology.

[32]  Alexander Hammers,et al.  PET image reconstruction using multi-parametric anato-functional priors , 2017, Physics in medicine and biology.

[33]  J. Nuyts The use of mutual information and joint entropy for anatomical priors in emission tomography , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[34]  Kris Thielemans,et al.  Hybrid PET-MR list-mode kernelized expectation maximization reconstruction , 2017, 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[35]  A. Reader,et al.  4D image reconstruction for emission tomography , 2014, Physics in medicine and biology.

[36]  Robert G. Aykroyd,et al.  Effect of PET-MR Inconsistency in the Kernel Image Reconstruction Method , 2019, IEEE Transactions on Radiation and Plasma Medical Sciences.

[37]  J. Colsher,et al.  Fully-three-dimensional positron emission tomography , 1980, Physics in medicine and biology.

[38]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[39]  Kris Thielemans,et al.  A survey of approaches for direct parametric image reconstruction in emission tomography. , 2008, Medical physics.

[40]  Anand Rangarajan,et al.  A new convex edge-preserving median prior with applications to tomography , 2003, IEEE Transactions on Medical Imaging.

[41]  Jing Tang,et al.  Bayesian PET image reconstruction incorporating anato-functional joint entropy. , 2009, Physics in medicine and biology.

[42]  L. J. Thomas,et al.  Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[43]  Guobao Wang,et al.  High Temporal-Resolution Dynamic PET Image Reconstruction Using A New Spatiotemporal Kernel Method , 2018, bioRxiv.

[44]  Martin A Lodge,et al.  Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application , 2013, Physics in medicine and biology.

[45]  Luigi Landini,et al.  Probabilistic Graphical Models for Dynamic PET: A Novel Approach to Direct Parametric Map Estimation and Image Reconstruction , 2020, IEEE Transactions on Medical Imaging.

[46]  Hisataka Kobayashi,et al.  Fluorescence lifetime imaging of activatable target specific molecular probes. , 2010, Contrast media & molecular imaging.

[47]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[48]  Yuichi Kimura,et al.  PET kinetic analysis—compartmental model , 2006, Annals of nuclear medicine.

[49]  Guobao Wang,et al.  Direct Estimation of Kinetic Parametric Images for Dynamic PET , 2013, Theranostics.

[50]  Martin A Lodge,et al.  Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation , 2013, Physics in medicine and biology.

[51]  H. Zaidi,et al.  Tracer Kinetic Modeling in PET. , 2007, PET clinics.

[52]  Nicolas A Karakatsanis,et al.  Hybrid PET/MR Kernelised Expectation Maximisation Reconstruction for Improved Image-Derived Estimation of the Input Function from the Aorta of Rabbits , 2019, Contrast media & molecular imaging.

[53]  T. Fuchs,et al.  Role of quantitative myocardial blood flow and 13N-ammonia washout for viability assessment in ischemic cardiomyopathy , 2019, Journal of Nuclear Cardiology.

[54]  Qianjin Feng,et al.  Anatomy-guided brain PET imaging incorporating a joint prior model , 2014, 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI).

[55]  Brian F. Hutton,et al.  Edge preserving bowsher prior with nonlocal weighting for 3D spect reconstruction , 2011, 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[56]  Habib Zaidi,et al.  Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET , 2015, Physics in medicine and biology.

[57]  Bruce D Cheson,et al.  Progress and Promise of FDG-PET Imaging for Cancer Patient Management and Oncologic Drug Development , 2005, Clinical Cancer Research.