Polarization image segmentation of radiofrequency ablated porcine myocardial tissue

Optical polarimetry has previously imaged the spatial extent of a typical radiofrequency ablated (RFA) lesion in myocardial tissue, exhibiting significantly lower total depolarization at the necrotic core compared to healthy tissue, and intermediate values at the RFA rim region. Here, total depolarization in ablated myocardium was used to segment the total depolarization image into three (core, rim and healthy) zones. A local fuzzy thresholding algorithm was used for this multi-region segmentation, and then compared with a ground truth segmentation obtained from manual demarcation of RFA core and rim regions on the histopathology image. Quantitative comparison of the algorithm segmentation results was performed with evaluation metrics such as dice similarity coefficient (DSC = 0.78 ± 0.02 and 0.80 ± 0.02), sensitivity (Sn = 0.83 ± 0.10 and 0.91 ± 0.08), specificity (Sp = 0.76 ± 0.17 and 0.72 ± 0.17) and accuracy (Acc = 0.81 ± 0.09 and 0.71 ± 0.10) for RFA core and rim regions, respectively. This automatic segmentation of parametric depolarization images suggests a novel application of optical polarimetry, namely its use in objective RFA image quantification.

[1]  David A. Jaffray,et al.  Wide-field tissue polarimetry allows efficient localized mass spectrometry imaging of biological tissues , 2015, Chemical science.

[2]  Marika A. Wallenburg,et al.  Effects of formalin fixation on tissue optical polarization properties , 2011, Physics in medicine and biology.

[3]  Hai-Shan Wu,et al.  Iterative thresholding for segmentation of cells from noisy images , 2000 .

[4]  Manjit Singh,et al.  Specimen shrinkage and its influence on margin assessment in breast cancer. , 2007, Asian journal of surgery.

[5]  Rui Seara,et al.  Image segmentation by histogram thresholding using fuzzy sets , 2002, IEEE Trans. Image Process..

[6]  R. Chipman,et al.  Interpretation of Mueller matrices based on polar decomposition , 1996 .

[7]  Nirmalya Ghosh,et al.  COMPARISON OF OPTICAL POLARIMETRY AND DIFFUSION TENSOR MR IMAGING FOR ASSESSING MYOCARDIAL ANISOTROPY , 2010 .

[8]  Yang Li,et al.  An In Vitro Assessment of Acoustic Radiation Force Impulse Imaging for Visualizing Cardiac Radiofrequency Ablation Lesions , 2010, Journal of cardiovascular electrophysiology.

[9]  Prashanthan Sanders,et al.  Catheter ablation of atrial arrhythmias: state of the art , 2012, The Lancet.

[10]  Andrew M Rollins,et al.  In vitro characterization of cardiac radiofrequency ablation lesions using optical coherence tomography. , 2010, Optics express.

[11]  Bernd Freisleben,et al.  RFA-cut: Semi-automatic segmentation of radiofrequency ablation zones with and without needles via optimal s-t-cuts , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  Jerry L Prince,et al.  Current methods in medical image segmentation. , 2000, Annual review of biomedical engineering.

[13]  L. R. Dice Measures of the Amount of Ecologic Association Between Species , 1945 .

[14]  Bülent Sankur,et al.  Survey over image thresholding techniques and quantitative performance evaluation , 2004, J. Electronic Imaging.

[15]  Andrew M Rollins,et al.  Real-time monitoring of cardiac radio-frequency ablation lesion formation using an optical coherence tomography forward-imaging catheter. , 2010, Journal of biomedical optics.

[16]  Jessica C Ramella-Roman,et al.  Imaging skin pathology with polarized light. , 2002, Journal of biomedical optics.

[17]  Anamika Ahirwar,et al.  Study of Techniques used for Medical Image Segmentation and Computation of Statistical Test for Region Classification of Brain MRI , 2013 .

[18]  Laura Waller,et al.  Partially coherent phase imaging with simultaneous source recovery. , 2015, Biomedical optics express.

[19]  Nirmalya Ghosh,et al.  Polarization birefringence measurements for characterizing the myocardium, including healthy, infarcted, and stem-cell-regenerated tissues. , 2010, Journal of biomedical optics.

[20]  Fei Zuo,et al.  Real-time lesion assessment using a novel combined ultrasound and radiofrequency ablation catheter. , 2011, Heart rhythm.

[21]  Sanaz Alali,et al.  Optical assessment of tissue anisotropy in ex vivo distended rat bladders. , 2012, Journal of biomedical optics.

[22]  R. Jiang,et al.  Shrinkage of head and neck cancer specimens after formalin fixation , 2012, Journal of the Chinese Medical Association : JCMA.

[23]  Erwin Bay,et al.  Three‐Dimensional Optoacoustic Monitoring of Lesion Formation in Real Time During Radiofrequency Catheter Ablation , 2015, Journal of cardiovascular electrophysiology.

[24]  David L Wilson,et al.  Semiautomatic parametric model-based 3D lesion segmentation for evaluation of MR-guided radiofrequency ablation therapy. , 2005, Academic radiology.

[25]  S. Andersson-Engels,et al.  Changes in tissue optical properties due to radio-frequency ablation of myocardium , 2003, Medical and Biological Engineering and Computing.

[26]  Lars Eckardt,et al.  Catheter Ablation of Ventricular Tachycardia , 2009, Herz Kardiovaskuläre Erkrankungen.

[27]  Angelo Pierangelo,et al.  Ex vivo photometric and polarimetric multilayer characterization of human healthy colon by multispectral Mueller imaging. , 2012, Journal of biomedical optics.

[28]  W. Stevenson,et al.  Preventing ventricular tachycardia with catheter ablation , 2010, The Lancet.

[29]  Santiago Aja-Fernández,et al.  A local fuzzy thresholding methodology for multiregion image segmentation , 2015, Knowl. Based Syst..

[30]  Angelo Pierangelo,et al.  Multispectral Mueller polarimetric imaging detecting residual cancer and cancer regression after neoadjuvant treatment for colorectal carcinomas , 2013, Journal of biomedical optics.

[31]  Mihaela Pop,et al.  Changes in dielectric properties at 460 kHz of kidney and fat during heating: importance for radio-frequency thermal therapy. , 2003, Physics in medicine and biology.

[32]  Sanaz Alali,et al.  Assessment of local structural disorders of the bladder wall in partial bladder outlet obstruction using polarized light imaging. , 2014, Biomedical optics express.

[33]  Antonello De Martino,et al.  Demonstration of full 4×4 Mueller polarimetry through an optical fiber for endoscopic applications. , 2015, Optics express.

[34]  Shakil Ahmad,et al.  Ex vivo characterization of normal and adenocarcinoma colon samples by Mueller matrix polarimetry , 2015, Journal of biomedical optics.

[35]  D Herranz,et al.  Novel catheter enabling simultaneous radiofrequency ablation and optical coherence reflectometry. , 2015, Biomedical optics express.

[36]  Anthony Kim,et al.  Quantitative correlation between light depolarization and transport albedo of various porcine tissues. , 2012, Journal of biomedical optics.

[37]  Nirmalya Ghosh,et al.  Tissue polarimetry: concepts, challenges, applications, and outlook. , 2011, Journal of biomedical optics.

[38]  I. Alex Vitkin,et al.  Detecting axial heterogeneity of birefringence in layered turbid media using polarized light imaging , 2012, Biomedical optics express.

[39]  J. Gil,et al.  Iterative thresholding for segmentation of cells from noisy images , 2000, Journal of microscopy.

[40]  M. Pop,et al.  Polarimetric assessment of healthy and radiofrequency ablated porcine myocardial tissue , 2016, Journal of biophotonics.

[41]  David L Lubell Drawbacks and limitations of computed tomography. , 2005, Texas Heart Institute journal.

[42]  E. S. Gardner,et al.  Predictable Tissue Shrinkage During Frozen Section Histopathologic Processing for Mohs Micrographic Surgery , 2001, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[43]  Sharon L. Thomsen,et al.  Mapping of thermal injury in biologic tissues using quantitative pathologic techniques , 1999, Photonics West - Biomedical Optics.

[44]  H Calkins,et al.  Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging. , 2000, Circulation.

[45]  Stanislav Emelianov,et al.  In vitro photoacoustic visualization of myocardial ablation lesions. , 2014, Heart rhythm.

[46]  Ron Kikinis,et al.  Statistical validation of image segmentation quality based on a spatial overlap index. , 2004, Academic radiology.

[47]  Alex Vitkin,et al.  A Monte Carlo study of penetration depth and sampling volume of polarized light in turbid media , 2008 .

[48]  W. Stevenson,et al.  Radiofrequency catheter ablation of ventricular tachycardia , 2000, Heart.

[49]  Arnold W. M. Smeulders,et al.  Interaction in the segmentation of medical images: A survey , 2001, Medical Image Anal..

[50]  Angelo Pierangelo,et al.  Polarimetric imaging of uterine cervix: a case study. , 2013, Optics express.

[51]  I. Nault,et al.  Catheter ablation for cardiac arrhythmias: a 14-year experience with 5330 consecutive patients at the Quebec Heart Institute, Laval Hospital. , 2007, The Canadian journal of cardiology.