Feedback control of the nuclear magnetization state: experimental results

In a previous paper (Proc. Soc. Magn. Reson. Med., San Francisco, CA, USA, 1991), the authors investigated feedback control of the nuclear magnetization state. This strategy facilitates the optimization of the pulse parameters during the imaging sequence. In this work, results from a series of experiments used to test the theoretical predictions are presented. Two groups of experiments were performed using a commercial imager and a small sample of distilled water. In the first group of experiments the control objective is to regulate the magnetization orientation to a constant reference angle. The results show that a closed-loop system produces the desired orientation. In contrast, an open-loop input results in an appreciable error between desired and measured orientation. A second group of experiments shows that a closed-loop system can force the magnetization orientation to track a desired trajectory. In both groups, the closed-loop experimental and simulation results are in excellent agreement. The application of feedback control to MRI and spectroscopy is discussed.

[1]  J. Schenck,et al.  An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T , 1985 .

[2]  R. Freeman,et al.  Phase and intensity anomalies in fourier transform NMR , 1971 .

[3]  Kensuke Sekihara,et al.  Steady-State Magnetizations in Rapid NMR Imaging Using Small Flip Angles and Short Repetition Intervals , 1987, IEEE Transactions on Medical Imaging.

[4]  W. W. Hansen,et al.  The Nuclear Induction Experiment , 1946 .

[5]  Norman F. Ramsey,et al.  Use of Rotating Coordinates in Magnetic Resonance Problems , 1954 .

[6]  A. Derome A simple composite pulse with low phase distortion , 1988 .

[7]  M. Mehring,et al.  Phase Transients in Pulsed NMR Spectrometers , 1972 .

[8]  A. Haase,et al.  Rapid NMR Imaging Using Low Flip-Angle Pulses , 2004 .

[9]  A. G. Butkovskii,et al.  Control of Quantum-Mechanical Processes and Systems , 1990 .

[10]  J. Tropp The theory of the bird-cage resonator , 1989 .

[11]  M. Weiner,et al.  Detection of residual Z magnetization, with application to the surface coil rotating frame experiment , 1987 .

[12]  M. Harpen The density matrix formalism of nuclear relaxation: a review. , 1988, Medical physics.

[13]  T. Mareci,et al.  Volume-localized spectroscopy using selective fourier transform with windowing by variable-tip-angle excitation , 1991 .

[14]  Peter G. Morris,et al.  Nmr Imaging in Biomedicine , 1982 .

[15]  S M Wright,et al.  Feedback control of the nuclear magnetization state: modeling and control design. , 1991, IEEE transactions on medical imaging.

[16]  B. Jakubczyk Feedback linearization of discrete-time systems , 1987 .