Miniaturization of Respiratory Measurement System in Artificial Ventilator for Small Animal Experiments to Reduce Dead Space and Its Application to Lung Elasticity Evaluation

A respiratory measurement system composed of pressure and airflow sensors was introduced to precisely control the respiratory condition during animal experiments. The flow sensor was a hot-wire thermal airflow meter with a directional detection and airflow temperature change compensation function based on MEMS technology, and the pressure sensor was a commercially available one also produced by MEMS. The artificial dead space in the system was minimized to the value of 0.11 mL by integrating the two sensors on the same plate (26.0 mm × 15.0 mm). A balloon made of a silicone resin with a hardness of A30 was utilized as the simulated lung system and applied to the elasticity evaluation of the respiratory system in a living rat. The inside of the respiratory system was normally pressurized without damage, and we confirmed that the developed system was able to evaluate the elasticity of the lung tissue in the rat by using the pressure value obtained at the quasi-static conditions in the case of the ventilation in the animal experiments.

[1]  Benjamin D Singer,et al.  Basic Invasive Mechanical Ventilation , 2009, Southern medical journal.

[2]  Louis Vessot King,et al.  On the Convection of Heat from Small Cylinders in a Stream of Fluid: Determination of the Convection Constants of Small Platinum Wires with Applications to Hot-Wire Anemometry , 1914 .

[3]  Arthur S Slutsky,et al.  A new ventilator for monitoring lung mechanics in small animals. , 2000, Journal of applied physiology.

[4]  L. Gattinoni,et al.  Ventilator-related causes of lung injury: the mechanical power , 2016, Intensive Care Medicine.

[5]  H. Funabashi,et al.  A Z-axis differential capacitive SOI accelerometer with vertical comb electrodes , 2004, 17th IEEE International Conference on Micro Electro Mechanical Systems. Maastricht MEMS 2004 Technical Digest.

[6]  Kazuo Sato,et al.  Flexible flow sensor for large-scale air-conditioning network systems , 2012 .

[7]  S. Senturia Microsystem Design , 2000 .

[8]  M. Shikida,et al.  Respiration and heartbeat signal detection from airflow at airway in rat by catheter flow sensor with temperature compensation function , 2017 .

[9]  Alain Giani,et al.  Studies and optimization of the frequency response of a micromachined thermal accelerometer , 2008 .

[10]  Micro-machined respiratory monitoring system development for artificial ventilator in animal experiment , 2020 .

[11]  Chih-Ming Ho,et al.  A micromachined flow shear-stress sensor based on thermal transfer principles , 1999 .

[12]  Li Cheng,et al.  Design of a new differential silicon resonant accelerometer with dual proofmasses using two-stage microlever , 2015, 2015 IEEE SENSORS.

[13]  N. MacIntyre Ventilator-associated pneumonia: the role of ventilator management strategies. , 2005, Respiratory care.

[14]  M. Shikida,et al.  Amicromachined active tactile sensor for hardness detection , 2004 .

[15]  D. Talmor,et al.  Targeting transpulmonary pressure to prevent ventilator induced lung injury. , 2009, Minerva anestesiologica.

[17]  Gregory T. A. Kovacs,et al.  A CMOS Compatible Traction Stress Sensing Element For Use In High Resolution Tactile Imaging , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[18]  Y. Tai,et al.  A parametrized three-dimensional model for MEMS thermal shear-stress sensors , 2005 .

[19]  Kazuo Sato,et al.  A MEMS flow sensor applied in a variable-air-volume unit in a building air-conditioning system , 2013 .

[20]  Arthur S Slutsky,et al.  Mechanical Ventilation: State of the Art. , 2017, Mayo Clinic proceedings.

[21]  Ubaidur Rahaman Mathematics of Ventilator-induced Lung Injury , 2017, Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine.

[22]  J. Marini Evolving concepts for safer ventilation , 2019, Critical Care.

[23]  Toshiyuki Tsuchiya,et al.  Polysilicon vibrating gyroscope vacuum-encapsulated in an on-chip micro chamber , 2001 .

[24]  Louis Vessot King,et al.  On the Convection of Heat from Small Cylinders in a Stream of Fluid: Determination of the Convection Constants of Small Platinum Wires, with Applications to Hot-Wire Anemometry , 1914 .

[25]  Sergej Fatikow,et al.  Microsystem Technology and Microrobotics , 1997, Springer Berlin Heidelberg.

[26]  V. Ranieri,et al.  Novel approaches to minimize ventilator-induced lung injury , 2015, Current opinion in critical care.

[27]  H. Robertson,et al.  Dead space: the physiology of wasted ventilation , 2014, European Respiratory Journal.

[28]  Diana Sommer,et al.  Sensor Technology And Devices , 2016 .

[29]  Bradford J. Smith,et al.  Ventilator-induced lung injury and lung mechanics. , 2018, Annals of translational medicine.

[30]  M. Aumann,et al.  Ventilator waveform interpretation in mechanically ventilated small animals. , 2011, Journal of veterinary emergency and critical care.

[31]  G. Stemme,et al.  Three dimensional silicon triple-hot-wire anemometer based on polyimide joints , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[32]  J. Marini,et al.  Static and Dynamic Contributors to Ventilator-induced Lung Injury in Clinical Practice. Pressure, Energy, and Power , 2020, American journal of respiratory and critical care medicine.

[33]  C M DRUMMOND,et al.  MECHANICAL VENTILATION. , 1964, North Carolina medical journal.

[34]  F. Rapetti,et al.  Driving pressure and mechanical power: new targets for VILI prevention. , 2017, Annals of translational medicine.

[35]  N. Habashi,et al.  Physiology in Medicine: Understanding dynamic alveolar physiology to minimize ventilator-induced lung injury , 2017, Journal of applied physiology.

[36]  Rong Zhu,et al.  A temperature compensation method for micromachined thermal gas gyroscope , 2015, 2015 IEEE SENSORS.

[37]  P. Pelosi,et al.  Power to mechanical power to minimize ventilator-induced lung injury? , 2019, Intensive Care Medicine Experimental.

[38]  Mitsuhiro Shikida,et al.  Catheter type thermal flow sensor with small footprint for measuring breathing function , 2018 .

[39]  B. Singer,et al.  Invasive Mechanical Ventilation , 2018, Southern medical journal.