Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.

OBJECTIVE The purpose of this study was to evaluate the accuracy and precision of a novel algorithm that evaluates cardiac output by using arterial pressure waveform characteristics. DESIGN Prospective, observational study comparing the cardiac output values of intermittent thermodilution, continuous thermodilution, and continuous arterial pressure wave assessment. SETTING The intensive care unit in a tertiary care university hospital. PARTICIPANTS Fifty postoperative cardiac surgical patients, within the first 12 hours after surgery. INTERVENTIONS All patients received a pulmonary artery catheter (PAC) and at least 1 systemic arterial pressure catheter. The data from the arterial catheter were processed by using a new arterial pressure cardiac output (APCO) algorithm. The data from the PAC (continuous and intermittent assessments) were collected for comparison with the APCO. MEASUREMENTS Two hundred ninety-five cardiac output measurements using intermittent thermodilution (ICO), continuous thermodilution (CCO), and arterial pressure-based output (APCO) were obtained during various times during the first 12 postoperative hours. The measurements of each method at each time point were compared by using Bland-Altman analysis. RESULTS The mean cardiac output ranged from 2.77 to 9.60 L/min. APCO, compared with ICO, revealed a bias of 0.55 L/min and precision of 0.98 L/min. APCO, compared with CCO, revealed a bias of 0.06 L/min and precision of 1.06 L/min. The APCO agreement between femoral and radial arterial catheters was close; the bias was -0.15 L/min, and the precision was 0.56 L/min. CONCLUSIONS This novel arterial pressure cardiac output algorithm provides cardiac output assessments that agree satisfactorily for clinical purposes with intermittent and continuous thermodilution techniques in postoperative cardiac surgical patients. Further study is required for other patient populations and clinical situations.

[1]  W. Buhre,et al.  Comparison of continuous cardiac output measurements in patients after cardiac surgery. , 2003, Journal of cardiothoracic and vascular anesthesia.

[2]  R. Williams,et al.  Computer estimation of stroke volume from aortic pulse contour in dogs and humans. , 1974, The Cardiology.

[3]  Hironori Ishihara,et al.  A New Non-Invasive Continuous Cardiac Output Trend Solely Utilizing Routine Cardiovascular Monitors , 2004, Journal of Clinical Monitoring and Computing.

[4]  Paolo Pietropaoli,et al.  Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation , 2003, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[5]  S. Gaffin,et al.  An evaluation of the pulse-contour method of measuring cardiac output. , 1984, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde.

[6]  N. T. Smith,et al.  A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. , 2001, British journal of anaesthesia.

[7]  T. Stanley,et al.  Comparison of Aortic Pulse‐wave Contour Analysis and Thermodilution Methods of Measuring Cardiac Output during Anesthesia in the Dog , 1980, Anesthesiology.

[8]  G. Langewouters,et al.  The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five component model. , 1985, Journal of biomechanics.

[9]  B. Reichart,et al.  Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution. , 1999, Critical care medicine.

[10]  Roger G. Mark,et al.  Continuous cardiac output monitoring by peripheral blood pressure waveform analysis , 2006, IEEE Transactions on Biomedical Engineering.

[11]  R. Jansen,et al.  Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac output. , 2002, Clinical science.

[12]  G. Manecke Edwards FloTrac™ sensor and Vigileo™ monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave , 2005, Expert review of medical devices.

[13]  M. Haller,et al.  Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery. , 2000, Journal of cardiothoracic and vascular anesthesia.

[14]  A. Abreu,et al.  Pulmonary Artery Rupture Induced by a Pulmonary Artery Catheter: A Case Report and Review of the Literature , 2004, Journal of intensive care medicine.

[15]  K. Kerr,et al.  Deep hypothermic circulatory arrest and the femoral-to-radial arterial pressure gradient. , 2004, Journal of cardiothoracic and vascular anesthesia.

[16]  G. Della Rocca,et al.  Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. , 2002, British journal of anaesthesia.

[17]  M. Jessen,et al.  PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery. , 2002, The Annals of thoracic surgery.

[18]  R. Cork,et al.  Entrapment of pulmonary artery catheter in a suture at the inferior vena cava cannulation site. , 2004, Journal of clinical anesthesia.