Analysing the potential of retrofitting ultra-low heat loss triple vacuum glazed windows to an existing UK solid wall dwelling

Heat loss through the windows of solid wall dwellings is one of the factors contributing to high energy consumption for space heating ensuing in preventable carbon emissions. This research forms a part of novel contribution in vacuum glazing science presenting the refurbishment technology of an experimentally achievable thermal performance of triple vacuum glazing to existing UK solid wall dwelling by investigating the space-heating load, solar energy gain and window to wall area ratios. Three-dimensional dynamic thermal models, considering realistic heating and occupancy regimes, of an externally insulated solid wall dwelling with single glazed, double glazed air filled, double glazed argon gas filled, triple glazed air filled and triple vacuum glazed windows were developed. Predictions for the simulated dwelling when replacing single glazed windows with triple vacuum glazed windows indicate space-heating energy saving of 14.58% (871.1 kWh) for the winter months (Dec, Jan and Feb); predicted annual energy savings are 15.31% (1863.5 kWh). The predicted reduction in the solar energy gains for the triple vacuum glazing was 75.3 kWh in the winter months. The effects on solar energy gain are analysed and the potential to increase window-to-wall area ratios (WWR's) examined. For a simulated room with triple vacuum glazed windows increasing the WWR's from 5% to 59% led to a reduction in the predicted required space-heating; whilst for a room with single glazed, double air filled, double argon gas filled and triple air filled windows the predicted required space-heating increased with increasing WWR. It was shown that retrofitting existing solid wall dwelling with triple vacuum glazed windows could be a robust retrofit solution in improving building energy efficiency. This research also implicates a need of the cost-effective development of triple vacuum glazing at the manufacturing level, which would then be more beneficial to consumers in terms of energy and cost savings.

[1]  Dennis L. Loveday,et al.  UK solid-wall dwellings - thermal comfort, energy efficiency refurbishment and the user perspective - some preliminary analysis from the CALEBRE project , 2010 .

[2]  Nick Baker,et al.  LT Method 3.0 — a strategic energy-design tool for Southern Europe , 1996 .

[3]  A. Donald,et al.  The small house in eighteenth-century London : a social and architectural history , 2004 .

[4]  Arild Gustavsen,et al.  Fenestration of Today and Tomorrow: A State-of-the-Art Review and Future Research Opportunities , 2013 .

[5]  Jon Moorhouse,et al.  The Low-Carbon Retrofit of a UK Conservation Area Terrace: Introducing a Pattern Book of Energy-Saving Details , 2012 .

[6]  Lisa Heschong,et al.  Daylight metrics and energy savings , 2009 .

[7]  Ted N. Carnes,et al.  Indoor sound criteria according to the American Society of Heating, Refrigerating and Air‐Conditioning Engineers (ASHRAE)—An introduction , 2005 .

[8]  Vice President,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. , 2007 .

[9]  Chris I. Goodier,et al.  Building orientation and occupancy patterns and their effect on interventions to reduce overheating in dwellings during heat waves. , 2010 .

[10]  M. Newborough,et al.  Reducing CO 2 emissions through refurbishment of UK housing , 2007 .

[11]  Chris I. Goodier,et al.  Ranking of interventions to reduce overheating in dwellings during heat waves [conference paper] , 2010 .

[12]  Konstantinos Papakostas,et al.  Occupational and energy behaviour patterns in Greek residences , 1997 .

[13]  Oar,et al.  Building Codes and Indoor Air Quality , 2014 .

[14]  Jan Hensen,et al.  Considerations on design optimization criteria for windows providing low energy consumption and high visual comfort , 2012 .

[15]  S. Memon Design, fabrication and performance analysis of vacuum glazing units fabricated with low and high temperature hermetic glass edge sealing materials , 2013 .

[16]  D. Jenkins,et al.  The value of retrofitting carbon-saving measures into fuel poor social housing , 2010 .

[17]  Pamela Lofthouse The Development of English Semi-detached Dwellings During the Nineteenth Century , 2013 .

[18]  Phillip Frank Gower Banfill,et al.  Energy‐led retrofitting of solid wall dwellings: technical and user perspectives on airtightness , 2011 .

[19]  Jon Hand,et al.  CONTRASTING THE CAPABILITIES OF BUILDING ENERGY PERFORMANCE SIMULATION PROGRAMS , 2008 .

[20]  Dennis L. Loveday,et al.  Refurbishing the UK's 'hard to treat' dwelling stock: understanding challenges and constraints , 2011 .