Improvement of DFIG dynamic performance during intermittent fire-through fault

The number of wind turbines connected to power grids have significantly increased during the last decade. This is mainly due to the convincing revolution in power electronic technology and the growing concern about greenhouse effect that is intensified due to the burning of fossil fuels. Variable-speed wind energy conversion systems (WECSs) such as doubly fed induction generators (DFIGs) are dominating the wind energy market due to their superior advantages over fixed-speed-based WECS which include more captured energy, less mechanical stress, and acoustical noise. DFIG is interfaced to the ac network through the grid-side voltage source converter (GSC) and rotor-side RSC to enable the variable-speed operation of the wind turbine and to provide reactive power support to the ac grid during disturbance events. Converter switching malfunction such as fire-through may influence the power dispatch capability of the DFIG. In this paper, a coil is proposed to be integrated within the DFIG converters to improve dynamic performance of DFIG-based WECS during internal converter switching malfunctions such as fire-through fault. Simulation results without and with the coil connected to the system are presented.

[1]  Li Wang,et al.  Stability Enhancement of DFIG-Based Offshore Wind Farm Fed to a Multi-Machine System Using a STATCOM , 2013, IEEE Transactions on Power Systems.

[2]  T.A. Haskew,et al.  Analysis of Decoupled d-q Vector Control in DFIG Back-to-Back PWM Converter , 2007, 2007 IEEE Power Engineering Society General Meeting.

[3]  A. Abu-Siada,et al.  Improvement of DFIG-based WECS performance using SMES unit , 2013, 2013 Australasian Universities Power Engineering Conference (AUPEC).

[4]  P. Student,et al.  Application of SMES to Enhance the Dynamic Performance of DFIG during Voltage Sag and Swell , 2014 .

[5]  A. Abu-Siada,et al.  Application of SMES to Enhance the Dynamic Performance of DFIG During Voltage Sag and Swell , 2012, IEEE Transactions on Applied Superconductivity.

[6]  Li Wang,et al.  Stability Analysis of an Integrated Offshore Wind and Seashore Wave Farm Fed to a Power Grid Using a Unified Power Flow Controller , 2013, IEEE Transactions on Power Systems.

[7]  Yongdong Li,et al.  Improved Crowbar Control Strategy of DFIG Based Wind Turbines for Grid Fault Ride-Through , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[8]  Chen Jian,et al.  Simplified Active and Reactive Power Control of Doubly Fed Induction Generator and the Simulation with STATCOM , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[9]  A. Y. Abdelaziz,et al.  Investigation of electrical dynamics of DFIG-based wind turbines during severe symmetrical grid voltage dips , 2012, 2012 International Conference on Engineering and Technology (ICET).

[10]  A. M. S. Yunus,et al.  Application of UPFC to improve the LVRT capability of wind turbine generator , 2012, 2012 22nd Australasian Universities Power Engineering Conference (AUPEC).

[11]  A. Abu-Siada,et al.  Application of SMES Unit to Improve DFIG Power Dispatch and Dynamic Performance During Intermittent Misfire and Fire-Through Faults , 2013, IEEE Transactions on Applied Superconductivity.

[12]  R. M. M. Pereira,et al.  Comparative study of STATCOM and SVC performance on Dynamic Voltage Collapse of an Electric Power System with Wind Generation , 2014, IEEE Latin America Transactions.

[13]  H. Abdi,et al.  Improved dynamic performance of wind energy conversion system by UPFC , 2013, 2013 IEEE International Conference on Industrial Technology (ICIT).

[14]  Bin Wu,et al.  An Overview of SMES Applications in Power and Energy Systems , 2010, IEEE Transactions on Sustainable Energy.

[15]  M Mohseni,et al.  Enhanced Hysteresis-Based Current Regulators in Vector Control of DFIG Wind Turbines , 2011, IEEE Transactions on Power Electronics.

[16]  A. Abu-Siada,et al.  Application of STATCOM to improve the high-voltage-ride-through capability of wind turbine generator , 2011, 2011 IEEE PES Innovative Smart Grid Technologies.

[17]  A.R. Milani,et al.  Dynamic and stability improvement of a wind farm connected to grid using UPFC , 2008, 2008 IEEE International Conference on Industrial Technology.

[18]  A. Abu-Siada,et al.  Application of SMES unit to improve the overall performance of DFIG-based WECS , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[19]  S Islam,et al.  Application of SMES Unit in Improving the Performance of an AC/DC Power System , 2011, IEEE Transactions on Sustainable Energy.

[20]  Sharad W. Mohod,et al.  A STATCOM-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement , 2010, IEEE Systems Journal.

[21]  Luis Marroyo,et al.  Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[22]  A. Abu-Siada,et al.  Application of STATCOM to improve the LVRT of DFIG during RSC fire-through fault , 2012, 2012 22nd Australasian Universities Power Engineering Conference (AUPEC).

[23]  Zhao Fang Crowbar Control Strategy for Doubly Fed Induction Generator of Wind Farm During Power Grid Voltage Dips , 2008 .

[24]  R.G. Harley,et al.  Real-Time Implementation of a STATCOM on a Wind Farm Equipped With Doubly Fed Induction Generators , 2006, IEEE Transactions on Industry Applications.