Measurement of water content of oil-water two-phase flows using dual-frequency microwave method in combination with deep neural network

Abstract This paper presents a microwave dual frequency correction algorithm to measure the water content of the oil-water two-phase flows, which can eliminate the influence of conductivity and obtain the water content. Subsequently, based on the advantages of dual-frequency this paper proposes a deep neural network model to predict complex nonlinear relationship between the mixture permittivity and water content. In order to avoid falling into a local optimal solution, the adaptive moment estimation algorithm is used to replace the gradient descent method. The experimental results are applied to estimate the performance of the discussed deep neural network algorithm.

[1]  Xiaoxiao Dong,et al.  Design of a Conductance and Capacitance Combination Sensor for water holdup measurement in oil–water two-phase flow , 2015 .

[2]  Tong Boon Tang,et al.  A High Resolution Capacitive Sensing System for the Measurement of Water Content in Crude Oil , 2014, Sensors.

[3]  Ebbe Gustaf Nyfors,et al.  Industrial Microwave Sensors—A Review , 2000 .

[4]  Muhammad Akram Karimi,et al.  A low cost and pipe conformable microwave-based water-cut sensor , 2016, 2016 IEEE MTT-S International Microwave Symposium (IMS).

[5]  Gioia Falcone,et al.  A microwave cavity resonator sensor for water-in-oil measurements , 2018, Sensors and Actuators B: Chemical.

[6]  Mahmoud Meribout,et al.  A Multisensor Intelligent Device for Real-Time Multiphase Flow Metering in Oil Fields , 2010, IEEE Transactions on Instrumentation and Measurement.

[7]  Alireza Bahadori,et al.  On the determination of crude oil salt content: application of robust modeling approaches , 2015 .

[8]  Geoffrey E. Hinton,et al.  Learning representations by back-propagating errors , 1986, Nature.

[9]  A. Mohamed,et al.  Effect of salinity and temperature on water cut determination in oil reservoirs , 2003 .

[10]  Gioia Falcone,et al.  Multiphase Flow Metering , 2010 .

[11]  Ning-De Jin,et al.  Effects of flow patterns and salinity on water holdup measurement of oil-water two-phase flow using a conductance method , 2016 .

[12]  Liu Haijiang An Improvement Approach for a Short Wave Absorption Type Water-in-oil Sensor , 2014 .

[13]  Øystein Lund Bø,et al.  Application of microwave spectroscopy for the detection of water fraction and water salinity in water/oil/gas pipe flow , 2002 .

[14]  Yi Li,et al.  Experimental measurement of oil–water two-phase flow by data fusion of electrical tomography sensors and venturi tube , 2017 .

[15]  Bokai Xia,et al.  Soft Measurement of Water Content in Oil-Water Two-Phase Flow Based on RS-SVM Classifier and GA-NN Predictor , 2014 .

[16]  R. Schirru,et al.  Flow regime identification and volume fraction prediction in multiphase flows by means of gamma-ray attenuation and artificial neural networks , 2010 .

[17]  Zhipeng Wu,et al.  Gas/oil/water flow measurement by electrical capacitance tomography , 2013 .