Development of rotary blood pump technology: past, present, and future.

Even though clinical acceptance of a nonpulsatile blood flow was demonstrated almost 45 years ago, the development of a nonpulsatile blood pump was completely ignored until 20 years ago. In 1979, the first author's group demonstrated that completely pulseless animals did not exhibit any abnormal physiology if 20% higher blood flows were provided to them. However, during the next 10 years (1979-1988), minimum efforts were provided for the development of a nonpulsatile, permanently implantable cardiac prosthesis. In 1989, the first author and his team at Baylor College of Medicine initiated a developmental strategy of various types of nonpulsatile rotary blood pumps, including a 2-day rotary blood pump for cardiopulmonary bypass application, a 2 week pump for ECMO and short-term circulatory assistance, a 2 year pump as a bridge to transplantation, and a permanently implantable cardiac prosthesis. Following the design and developmental strategy established in 1989, successful development of a 2-day pump (the Nikkiso-Fairway cardiopulmonary bypass pump) in 4 years (1989-1993), a 2 week pump (Kyocera gyro G1E3 pump) in 6 years (1992-1998), and a bridge to transplant pump (DeBakey LVAD-an axial flow blood pump) in 10 years (1988-1998) was made. Currently, a permanently implantable centrifugal blood pump development program is successfully completing its initial Phase 1 program of 5 years (1995-2000). Implantation exceeded 9 months without any negative findings. An additional 5 year Phase II program (2000-2005) is expected to complete such a device that will be clinically available.

[1]  H Harasaki,et al.  Chronic nonpulsatile blood flow in an alive, awake animal 34-day survival. , 1980, Transactions - American Society for Artificial Internal Organs.

[2]  Kozo Naito,et al.  Comparative Hemolysis Study of Clinically Available Centrifugal Pumps. , 1996, Artificial organs.

[3]  R Kiraly,et al.  Comparative evaluation of nonpulsatile and pulsatile cardiac prostheses. , 1980, Transactions - American Society for Artificial Internal Organs.

[4]  G Damm,et al.  Initial clinical experience with the Baylor-Nikkiso centrifugal pump. , 1995, Artificial organs.

[5]  Y Nosé The need for the development of therapeutically combined artificial organs. , 1997, Artificial organs.

[6]  G L Hallman,et al.  Orthotopic cardiac prosthesis for two-staged cardiac replacement. , 1969, The American journal of cardiology.

[7]  Y Nosé,et al.  Development and initial testing of a permanently implantable centrifugal pump. , 1997, Artificial organs.

[8]  U Schütt,et al.  Bridging to Cardiac Transplantation With the Thoratec Ventricular Assist Device , 1999, The Thoracic and cardiovascular surgeon.

[9]  T Takano,et al.  A new control method that estimates the backflow in a centrifugal pump. , 1999, Artificial organs.

[10]  M. Debakey,et al.  Prolonged partial left ventricular bypass by means of an intrathoracic pump implanted in the left chest. , 1962, Transactions - American Society for Artificial Internal Organs.

[11]  S Takatani,et al.  Evaluation of the Wear of the Pivot Bearing in the Gyro C1E3 Pump. , 1996, Artificial organs.

[12]  R Hetzer,et al.  Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device. , 1999, The Annals of thoracic surgery.

[13]  Y Nosé,et al.  Therapeutic and physiological artificial heart: future prospects. , 1997, Artificial organs.

[14]  Yukihiko Nose,et al.  Clinical Comparative Study of Cardiopulmonary Bypass with Nikkiso and BioMedicus Centrifugal Pumps. , 1996, Artificial organs.

[15]  T Noda,et al.  Development of an atraumatic small centrifugal pump for second-generation cardiopulmonary bypass. , 2008, Artificial organs.

[16]  Y Nosé,et al.  A compact centrifugal pump for cardiopulmonary bypass. , 2008, Artificial organs.

[17]  Y Nosé,et al.  Long-term in vivo left ventricular assist device study with a titanium centrifugal pump. , 1998, ASAIO journal.

[18]  S. Murali,et al.  Mechanical circulatory support with the Novacor LVAS: world-wide clinical results. , 1999, The Thoracic and cardiovascular surgeon.

[19]  Y Nosé,et al.  A seal-less centrifugal pump (Baylor Gyro Pump) for application to long-term circulatory support. , 1993, Artificial organs.

[20]  R. Körfer,et al.  Temporary pulsatile ventricular assist devices and biventricular assist devices. , 1999, The Annals of thoracic surgery.

[21]  Poirier Vl,et al.  Worldwide Experience With the TCI HeartMate® System: Issues and Future Perspective , 1999, The Thoracic and cardiovascular surgeon.

[22]  P E Oyer,et al.  Thirty years of cardiac transplantation at Stanford university. , 1999, The Journal of thoracic and cardiovascular surgery.

[23]  Y Nosé,et al.  Initial experience with the Nikkiso centrifugal pump during thoracoabdominal aortic aneurysm repair. , 1998, Journal of vascular surgery.

[24]  O. Frazier,et al.  The development, evolution, and clinical utilization of artificial heart technology. , 1997, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[25]  Y Nosé,et al.  Eccentric inlet port of the pivot bearing supported Gyro centrifugal pump. , 2008, Artificial organs.

[26]  Y Nosé,et al.  In vitro performance of the Baylor/NASA axial flow pump. , 2008, Artificial organs.

[27]  Y Nosé,et al.  Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump. , 1997, Artificial organs.

[28]  H Harasaki,et al.  Comparison of hemodynamic changes in a chronic nonpulsatile biventricular bypass (BVB) and total artificial heart (TAH). , 1980, Transactions - American Society for Artificial Internal Organs.

[29]  Y. Nosé,et al.  Experimental use of an electronically controlled prosthesis as an auxiliary left ventricle. , 1963, Transactions - American Society for Artificial Internal Organs.

[30]  Y Nosé,et al.  Development of a totally implantable biventricular bypass centrifugal blood pump system. , 1999, The Annals of thoracic surgery.

[31]  H. Schima,et al.  Current Progress in the Development of a Totally Implantable Gyro Centrifugal Artificial Heart , 1998, ASAIO journal.

[32]  Y Nosé,et al.  Design and development strategy for the rotary blood pump. , 1998, Artificial organs.

[33]  Y Nosé,et al.  Arterial pressure pulsation during nonpulsatile biventricular bypass experiments: possible idioperipheral pulsation. , 1986, Artificial organs.

[34]  R Yozu,et al.  A miniaturized centrifugal pump for assist circulation. , 1994, Artificial organs.

[35]  D B Olsen,et al.  Chronic survival of calves implanted with the DeBakey ventricular assist device. , 1999, Artificial organs.