Comparison of laser surface scanning and fiducial marker-based registration in frameless stereotaxy. Technical note.

The authors compared the accuracy of laser surface scanning patient registration using the commercially available Fazer (Medtronic, Inc.) with the conventional registration procedure based on fiducial markers (FMs) in computer-assisted surgery. Four anatomical head specimens were prepared with 10 titanium microscrews placed at defined locations and scanned with a 16-slice spiral computed tomography unit. To compare the two registration methods, each method was applied five times for each cadaveric specimen; thus data were obtained from 40 registrations. Five microscrews (selected following a randomization protocol) were used for each FM-based registration; the other five FMs were selected for coordinate measurements by touching with a point measurement stylus. Coordinates of these points were also measured manually on the screen of the navigation computer. Coordinates were measured in the same manner after laser surface registration. The root mean square error as calculated by the navigation system ranged from 1.3 to 3.2 mm (mean 1.8 mm) with the Fazer and from 0.3 to 1.8 mm (mean 1.0 mm) with FM-based registration. The overall mean deviations (the arithmetic mean of the mean deviations of measurements on the four specimens) were 3.0 mm (standard deviation [SD] range 1.4-2.6 mm) with the Fazer and 1.4 mm (SD range 0.4-0.9 mm) with the FMs. The Fazer registration scans 300 surface points. Statistical tests showed the difference in the accuracy of these methods to be highly significant. In accordance with the findings of other groups, the authors concluded that the inclusion of a larger number of registration points might improve the accuracy of Fazer registration.

[1]  T. Kanade,et al.  Ultrasound Registration of the Bone Surface for Surgical Navigation , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[2]  Martin Styner,et al.  A-mode ultrasound-based registration in computer-aided surgery of the skull. , 2003, Archives of otolaryngology--head & neck surgery.

[3]  Jean-Claude Latombe,et al.  Image-Guided Robotic Radiosurgery , 1994, Modelling and Planning for Sensor Based Intelligent Robot Systems.

[4]  V. Seifert,et al.  Laser Surface Scanning for Patient Registration in Intracranial Image-guided Surgery , 2002, Neurosurgery.

[5]  R. Marmulla,et al.  Soft Tissue Scanning for Patient Registration in Image-Guided Surgery , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[6]  S Hassfeld,et al.  Automated laser registration in image-guided surgery: evaluation of the correlation between laser scan resolution and navigation accuracy. , 2004, International journal of oral and maxillofacial surgery.

[7]  Joachim Mühling,et al.  Markerless laser registration in image-guided oral and maxillofacial surgery. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[8]  S Hassfeld,et al.  High-Resolution Laser Surface Scanning for Patient Registration in Cranial Computer-Assisted Surgery , 2004, Minimally invasive neurosurgery : MIN.

[9]  Benoit M Dawant,et al.  Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking. , 2003, Medical physics.

[10]  J Schlaier,et al.  Registration accuracy and practicability of laser-directed surface matching. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[11]  H Bergmann,et al.  In-vitro assessment of a registration protocol for image guided implant dentistry. , 2001, Clinical oral implants research.

[12]  Wolfgang Birkfellner,et al.  Wobbled splatting—a fast perspective volume rendering method for simulation of x-ray images from CT , 2005, Physics in medicine and biology.

[13]  Wolfgang Birkfellner,et al.  A faster method for 3D/2D medical image registration—a simulation study , 2003, Physics in medicine and biology.