Multiframe x‐ray imaging system for temporally and spatially resolved measurements of imploding inertial confinement fusion targets

A compact and simple multiframe x‐ray imaging system was developed in order to monitor the implosion of spherical targets in inertial confinement fusion research. Time intervals between consecutive frames can be adjusted flexibly, and the maximum number of adjacent frames is 20 for an overall duration of 1.4 ns. Each frame is recorded with a temporal resolution of 83±20 ps, a spatial resolution of 10 lp/mm at a modulation transfer function of 20%, and an intensity dynamic range of 103. A proximity focused image intensifier with two microchannel plates allows to obtain a gain of 105. Measured temporal response and gain characteristics could be reproduced by a simple Monte Carlo calculation.

[1]  A. Lieber Nanosecond Gating of Proximity Focused Channel Plate Intensifiers , 1972 .

[2]  H. Kume,et al.  Computer Analysis of the Timing Properties in Micro Channel Plate Photomultiplier Tubes , 1984, IEEE Transactions on Nuclear Science.

[3]  D. Mestdagh Fiber-grating pulse compressor: Performance with initially chirped pulses. , 1987, Applied optics.

[4]  B. L. Henke,et al.  The characterization of x‐ray photocathodes in the 0.1–10‐keV photon energy region , 1981 .

[5]  Bradley,et al.  Cryogenic-laser-fusion target implosion studies performed with the OMEGA uv-laser system. , 1989, Physical review. A, General physics.

[6]  R. Kalibjian,et al.  Framing camera tube for subnanosecond imaging applications , 1983 .

[7]  Charles V. Shank,et al.  Compression of optical pulses chirped by self-phase modulation in fibers , 1984 .

[8]  Hiroshi Azechi,et al.  Scalings of implosion experiments for high neutron yield , 1988 .

[9]  P. Bell,et al.  High‐speed gated x‐ray imagers (invited) , 1988 .

[10]  M. D. Pocha,et al.  1000‐V, 300‐ps pulse‐generation circuit using silicon avalanche devices , 1985 .

[11]  R. Luppi,et al.  Pulsed microchannel‐plate mounting for subnanosecond x‐ray image intensifiers , 1984 .

[12]  O. Landen,et al.  X‐ray framing camera for picosecond imaging of laser‐produced plasmas , 1989 .

[13]  R. Wilcox,et al.  Ultrafast turnoff laser triggered gating system for microchannel-plate intensified x-ray spectrometers , 1985 .

[14]  J. D. Kilkenny,et al.  High Speed Gated X-Ray Imagers , 1988, Photonics West - Lasers and Applications in Science and Engineering.

[15]  Subnanosecond x‐ray framing camera , 1985 .

[16]  J. Kilkenny,et al.  Four‐frame gated optical imager with 120‐ps resolution (invited) , 1988 .

[17]  J. B. Hopkins,et al.  Regenerative amplification of temporally compressed picosecond pulses at 2 kHz , 1986 .

[18]  Irwin J. Abramovitz Acousto-Optic Processors For Passive Surveillance , 1985, Other Conferences.