Computational and Experimental Study of Surcharged Flow at a 90° Combining Sewer Junction

Combining sewer junctions with a lateral inflow at 90° angle are commonly used in our sewer systems. A computational fluid dynamics (CFD) model based on Ansys CFX 10.0 was established to simulate fully surcharged flow at a 90° combining sewer junction. The model was carefully assessed by comparing its results with the measurements of detailed physical experiments. Good agreement was obtained between results of the computational model and of the laboratory experiments. The computational model was proved to be capable of simulating surcharged combining junction flow in the aspects of water depth, energy losses, velocity distributions, and turbulence. The verified CFD model was also used to investigate air entrainment and effects of the size of the junction chamber on the flow. Such CFD models can be used to optimize the design of sewer junctions and will also be useful in studying sediment transport at sewer junctions.