Diagnosis of stator short-circuit faults in series and parallel winding connections of closed-loop controlled PMSMs

Stator winding short-circuit faults are among the most common faults that could occur in permanent magnet synchronous machines (PMSM). Therefore, on-line diagnosis of incipient stator winding short-circuit faults plays an important role contributing to the safe operation of PMSMs. However, the efficacy of known diagnostic methods varies with the types of stator winding configurations in PMSMs. This paper compares the effectiveness of diagnosis of stator winding short-circuit faults in series and parallel winding connections of PMSMs, with the same interior permanent-magnet rotor configuration. Two existing diagnostic methods have been applied to detect the severity of stator short-circuit faults happening in both series and parallel winding connection in PMSMs. Simulation analysis has been carried out in ANSYS Maxwell to compare the severity of magnetic saturation caused by equivalent short-circuit fault in series and parallel winding connected PMSMs. Experimental results lead to the conclusion that PMSMs with parallel winding connections can mask the influence of such stator short-circuit faults under certain circumstances, and thus it is more challenging to detect such incipient faults in parallel-winding-connected PMSM in comparison with series-winding-connected PMSMs.

[1]  E.L. Owen,et al.  Assessment of the Reliability of Motors in Utility Applications - Updated , 1986, IEEE Transactions on Energy Conversion.

[2]  C. Gerada,et al.  On-line detection of stator winding short-circuit faults in a PM machine using HF signal injection , 2008, 2008 18th International Conference on Electrical Machines.

[3]  Peng Zhang,et al.  Diagnosis of stator short-circuit faults in an IPM synchronous machine using a space-vector pendulous oscillation method , 2013, 2013 International Electric Machines & Drives Conference.

[4]  Nabeel A. O. Demerdash,et al.  Diagnosis of stator winding short-circuit faults in an interior permanent magnet synchronous machine , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[5]  Leila Parsa,et al.  Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors , 2011, IEEE Transactions on Industrial Electronics.

[6]  Kyeong-Hwa Kim,et al.  Simple Online Fault Detecting Scheme for Short-Circuited Turn in a PMSM Through Current Harmonic Monitoring , 2011, IEEE Transactions on Industrial Electronics.

[7]  Luis Romeral,et al.  Short-Circuit Detection by Means of Empirical Mode Decomposition and Wigner–Ville Distribution for PMSM Running Under Dynamic Condition , 2009, IEEE Transactions on Industrial Electronics.

[8]  William James Premerlani,et al.  A new approach to on-line turn fault detection in AC motors , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[9]  B. Mirafzal,et al.  On innovative methods of induction motor interturn and broken-bar fault diagnostics , 2006, IEEE Transactions on Industry Applications.

[10]  D. G. Dorrell,et al.  Influence of Parallel Paths on Current-Regulated Sine-Wave Interior-Permanent-Magnet Machines With Rotor Eccentricity , 2012, IEEE Transactions on Industry Applications.

[11]  Luis Romeral,et al.  Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults , 2011, IEEE Transactions on Industrial Electronics.

[12]  B. Mirafzal,et al.  On innovative methods of induction motor inter-turn and broken-bar fault diagnostics , 2005, IEEE International Conference on Electric Machines and Drives, 2005..

[13]  Thomas G. Habetler,et al.  An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.