Comparison of artificial eye amplitudes with acrylic and hydroxyapatite spherical enucleation implants.

PURPOSE To compare artificial eye amplitudes in patients who randomly received either a hydroxyapatite or an acrylic, scleral-covered spherical implant after enucleation. DESIGN Randomized, controlled trial. PARTICIPANTS Thirty-four consecutive patients who underwent enucleation because of an intraocular melanoma and 21 healthy control participants from the hospital staff. METHODS Eligible patients randomly received a hydroxyapatite or an acrylic, scleral-covered spherical orbital implant. Fourteen patients were fitted with a hydroxyapatite implant, and 16 were fitted with an acrylic implant. We measured horizontal and vertical saccadic amplitudes of both the artificial eye and the healthy eye. Measurements were performed with the magnetic search coils technique. Saccadic amplitudes of the artificial eye were compared with the healthy eye of the patient. The amplitudes of the healthy eyes were compared with saccadic amplitudes of control participants. The interval from surgery to measurements was at least 3 months in all patients. Saccadic gain (artificial eye and eye amplitude divided by target amplitude) and saccadic symmetry (artificial eye amplitude divided by healthy eye amplitude) were calculated. MAIN OUTCOME MEASURES Saccadic gain and saccadic symmetry. RESULTS The gain in the healthy eyes of the patients was comparable with the gain of the control eyes. Saccadic symmetry was 1.0 in control participants. In patients, it was 0.334 in horizontal saccades and 0.577 in vertical saccades. However, saccadic symmetry did not differ significantly between the acrylic group and the hydroxyapatite group (P: > 0.1 for any saccadic direction). Equivalence was detectable with a power more than 90% for horizontal saccades and more than 80% for vertical saccades. Curvilinearity was rejected for both patient groups and for all saccadic directions (P: > 0.5). CONCLUSIONS When no motility peg is placed, acrylic and hydroxyapatite spherical implants yield comparable saccadic amplitudes of the artificial eye. Artificial eye amplitudes were markedly more restricted horizontally than vertically. In all saccadic directions, the relation between target amplitude and artificial eye amplitude was linear.

[1]  E. Kemp,et al.  The Mersilene covered intraorbital implant , 1992, Eye.

[2]  J. Ashworth,et al.  The hydroxyapatite orbital implant: A prospective study , 1996, Eye.

[3]  H. Collewijn,et al.  Precise recording of human eye movements , 1975, Vision Research.

[4]  C. Shields,et al.  Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant. , 1991, American journal of ophthalmology.

[5]  H Collewijn,et al.  Conjugacy of eyelid movements in vertical eye saccades. , 1995, Investigative ophthalmology & visual science.

[6]  C. Shields,et al.  Role of magnetic resonance imaging in the evaluation of the hydroxyapatite orbital implant. , 1992, Ophthalmology.

[7]  C. Shields,et al.  Hydroxyapatite orbital implant after enucleation. Experience with initial 100 consecutive cases. , 1992, Archives of ophthalmology.

[8]  J. Dutton Coralline hydroxyapatite as an ocular implant. , 1991, Ophthalmology.

[9]  J. Dutton,et al.  Rate of vascularization of coralline hydroxyapatite ocular implants. , 1992, Ophthalmology.

[10]  Ashutosh Kumar Singh,et al.  Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases. , 1994, The British journal of ophthalmology.

[11]  J. Kwartz,et al.  The ‘baseball’ orbital implant: A prospective study , 1994, Eye.

[12]  J. Collin,et al.  Baseball orbital implants: a review of 39 patients. , 1985, The British journal of ophthalmology.

[13]  R. Hurtig,et al.  A system for measurement of prosthetic eye movements using a magnetic search coil technique. , 1990 .

[14]  B. Frueh,et al.  Baseball implant. A method of secondary insertion of an intraorbital implant. , 1976, Archives of ophthalmology.

[15]  D. Soll,et al.  The anophthalmic socket. , 1982, Ophthalmology.

[16]  D. Robinson,et al.  A METHOD OF MEASURING EYE MOVEMENT USING A SCLERAL SEARCH COIL IN A MAGNETIC FIELD. , 1963, IEEE transactions on bio-medical engineering.

[17]  K. Trinkaus,et al.  Comparative motility of hydroxyapatite and alloplastic enucleation implants. , 1999, Ophthalmology.