Maximum cross-entropy generalized series reconstruction

This article addresses the classical image reconstruction problem from limited Fourier data. In particular, we deal with the issue of how to incorporate constraints provided in the form of a high-resolution reference image which approximates the desired image. A new algorithm is described which represents the desired image using a family of basis functions derived from translated and rotated versions of the reference image. The selection of the most efficient basis function set from this family is guided by the principle of maximum cross-entropy. Simulation and experimental results have shown that the algorithm can achieve high resolution with a small number of data points while accounting for relative misregistration between the reference and measured data. The technique proves to be useful for a number of time-sequential magnetic resonance imaging applications, for which significant improvement in temporal resolution can be obtained, even as the object undergoes bulk motion during the acquisition.

[1]  P. Lauterbur,et al.  An efficient method for dynamic magnetic resonance imaging , 2002, 5th IEEE EMBS International Summer School on Biomedical Imaging, 2002..

[2]  David Atkinson,et al.  Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion , 1997, IEEE Transactions on Medical Imaging.

[3]  Z P Liang,et al.  A simulation study to assess SVD encoding for interventional MRI: Effect of object rotation and needle insertion , 1996, Journal of magnetic resonance imaging : JMRI.

[4]  Michael Unser,et al.  Convolution-based interpolation for fast, high-quality rotation of images , 1995, IEEE Trans. Image Process..

[5]  L P Panych,et al.  A dynamically adaptive imaging algorithm for wavelet‐encoded MRI , 1994, Magnetic resonance in medicine.

[6]  F. Jolesz,et al.  Dynamically adaptive MRI with encoding by singular value decomposition , 1994, Magnetic resonance in medicine.

[7]  X Hu,et al.  On the “keyhole” technique , 1994, Journal of magnetic resonance imaging : JMRI.

[8]  T. Spraggins Simulation of spatial and contrast distortions in keyhole imaging , 1994, Magnetic resonance in medicine.

[9]  D C Harrison,et al.  Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography , 1993, Journal of magnetic resonance imaging : JMRI.

[10]  Yue Cao,et al.  Feature‐recognizing MRI , 1993, Magnetic resonance in medicine.

[11]  Lisa M. Brown,et al.  A survey of image registration techniques , 1992, CSUR.

[12]  Ronald R. Coifman,et al.  Entropy-based algorithms for best basis selection , 1992, IEEE Trans. Inf. Theory.

[13]  R. Gray Entropy and Information Theory , 1990, Springer New York.

[14]  G. Golub Matrix computations , 1983 .

[15]  Rodney W. Johnson,et al.  Axiomatic derivation of the principle of maximum entropy and the principle of minimum cross-entropy , 1980, IEEE Trans. Inf. Theory.