Anatomical Considerations for Subaxial (C2) Pedicle Screw Placement: A Radiographic Study With Computed Tomography in 93 Patients

Study Design Radiographic study. Objective More detailed anatomical knowledge of the C2 pedicle is required to optimize and minimize the risk of screw placement. The aim of this study was to evaluate the linear and angular dimensions of the true C2 pedicle using axial computed tomography. Background Data Although earlier studies have analyzed the anatomy of the C2 pars interarticularis, little attention has been focused on the dimensions of the C2 pedicle. Methods Ninety-three patients (47 males, 46 females; mean age 48.4 y) who had previous cervical spinal computed tomography imaging were evaluated for this study. Axial images of the C2 pedicle were selected and the following pedicle parameters were determined: pedicle width (the mediolateral diameter of the pedicle isthmus, perpendicular to the pedicle axis) and pedicle transverse angle (PTA, ie, the angle between the pedicle axis and the midline of the vertebral body). Results The overall mean pedicle width was 5.8±1.2 mm. The mean pedicle width in male patients (6.0±1.3 mm) was greater than that in the female patients (5.6±1.1 mm). This difference was not found to be statistically significant (P=0.679). The overall mean PTA was 43.9±3.9 degrees. The mean PTA in male patients was 43.2±3.8 degrees, whereas that in female patients was 44.7±3.7 degrees. Conclusions Given the significant variability in pedicle widths and the need for precise trajectory planning in pedicle cannulation, preoperative planning is absolutely mandatory. A significant percentage of patients have pedicle widths that may not accommodate screw fixation. In addition, the angle of entry into the C2 pedicle must be carefully measured for safe instrumentation at this level.

[1]  A. Goel C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. , 2002, Neurosurgery.

[2]  K. Fountas,et al.  C1-C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience. , 2002, Neurosurgery.

[3]  B. Subach,et al.  C1–C2 Transarticular Screw Fixation for Atlantoaxial Instability: A 6-year Experience , 2001, Neurosurgery.

[4]  J. Howington,et al.  Surgical anatomy of the C-2 pedicle. , 2001, Journal of neurosurgery.

[5]  N. Ebraheim,et al.  The Location of the Pedicle and Pars Interarticularis in the Axis , 2001, Spine.

[6]  R. Yeasting,et al.  Quantitative anatomy of the transverse foramen and pedicle of the axis. , 1998, Journal of spinal disorders.

[7]  R. Gaines,et al.  Morphologic Characteristics of Human Cervical Pedicles , 1997, Spine.

[8]  N. Crawford,et al.  Biomechanical characteristics of C1-2 cable fixations. , 1996, Journal of neurosurgery.

[9]  N. Ebraheim,et al.  Anatomic Consideration of C2 Pedicle Screw Placement , 1996, Spine.

[10]  E. Benzel Anatomic consideration of C2 pedicle screw placement. , 1996, Spine.

[11]  R. Yeasting,et al.  Morphology of the Second Cervical Vertebra and the Posterior Projection of the C2 Pedicle Axis , 1995, Spine.

[12]  M. Bernstein,et al.  C1-C2 posterior cervical fusion: long-term evaluation of results and efficacy. , 1995, Neurosurgery.

[13]  C. Dickman,et al.  Posterior atlantoaxial facet screw fixation. , 1993, Journal of neurosurgery.

[14]  M M Panjabi,et al.  Biomechanical Evaluation of Four Different Posterior Atlantoaxial Fixation Techniques , 1992, Spine.

[15]  M. Aebi,et al.  Atlanto-axial fusion with transarticular screw fixation. , 1991, The Journal of bone and joint surgery. British volume.

[16]  G. Borne,et al.  Treatment of pedicular fractures of the axis. A clinical study and screw fixation technique. , 1984, Journal of neurosurgery.