Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system

The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measurements by combining the Si-PM-based PET and the 0.15 T permanent MRI to test the interferences between the Si-PM-based PET and an MRI. When the Si-PM was inside the MRI and installed around the radio frequency (RF) coil of the MRI, significant noise from the RF sequence of the MRI was observed in the analog signals of the PET detectors. However, we did not observe any artifacts in the PET images; fluctuation increased in the count rate of the Si-PM-based PET system. On the MRI side, there was significant degradation of the signal-to-noise ratio (S/N) in the MRI images compared with those without PET. By applying noise reduction procedures, the degradation of the S/N was reduced. With this condition, simultaneous measurements of a rat brain using a Si-PM-based PET and an MRI were made with some degradation in the MRI images. We conclude that simultaneous measurements are possible using Si-PM-based PET and MRI.

[1]  S. Cherry,et al.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  E. Atalar,et al.  Ultimate intrinsic signal‐to‐noise ratio in MRI , 1998, Magnetic resonance in medicine.

[3]  S. Cherry,et al.  Simultaneous in vivo positron emission tomography and magnetic resonance imaging , 2008, Proceedings of the National Academy of Sciences of the United States of America.

[4]  Ciprian Catana,et al.  Simultaneous PET-MRI: a new approach for functional and morphological imaging , 2008, Nature Medicine.

[5]  Seiichi Yamamoto,et al.  A temperature-dependent gain control system for improving the stability of Si-PM-based PET systems , 2011, Physics in medicine and biology.

[6]  Simon R. Cherry,et al.  Development of a PET detector system compatible with MRI/NMR systems , 1997 .

[7]  T. Carpenter,et al.  Silicon photomultiplier performance tests in magnetic resonance pulsed fields , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[8]  H. Murayama,et al.  A block detector for a multislice, depth-of-interaction MR-compatible PET , 2005, IEEE Transactions on Nuclear Science.

[9]  Ciprian Catana,et al.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  Eiji Sugiyama,et al.  Design and performance from an integrated PET/MRI system for small animals , 2010, Annals of nuclear medicine.

[11]  Kagayaki Kuroda,et al.  Scintillator selection for MR compatible gamma detectors , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[12]  Kagayaki Kuroda,et al.  Development of an MR-compatible gamma probe for combined MR/RI guided surgery. , 2004, Physics in medicine and biology.

[13]  Kotaro Minato,et al.  A Multi-Slice Dual Layer MR-Compatible Animal PET System , 2009 .

[14]  Eiji Sugiyama,et al.  Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system , 2011, Physics in medicine and biology.

[15]  Yiping Shao,et al.  PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat hearts , 1997, NMR in biomedicine.

[16]  Stan Majewski,et al.  Simultaneous MRI and PET imaging of a rat brain. , 2006, Physics in medicine and biology.

[17]  In Chan Song,et al.  An Investigation Into the Use of Geiger-Mode Solid-State Photomultipliers for Simultaneous PET and MRI Acquisition , 2008, IEEE Transactions on Nuclear Science.

[18]  Simon R. Cherry,et al.  Design of a small animal MR compatible PET scanner , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[19]  L. Dougherty,et al.  A direct comparison of signal behavior between 4.0 and 1.5 T: a phantom study. , 2003, European journal of radiology.

[20]  S. Cherry,et al.  Simultaneous PET and MR imaging , 1997, Physics in medicine and biology.

[21]  R. Mirzoyan,et al.  A test of silicon photomultipliers as readout for PET , 2005 .

[22]  Tadashi Watabe,et al.  Development of a Si-PM-based high-resolution PET system for small animals , 2010, Physics in medicine and biology.

[23]  L. Cosentino,et al.  Features of Silicon Photo Multipliers: Precision Measurements of Noise, Cross-Talk, Afterpulsing, Detection Efficiency , 2009, IEEE Transactions on Nuclear Science.

[24]  M. G. Bisogni,et al.  Studies of silicon photomultipliers at cryogenic temperatures , 2011 .

[25]  Dieter Renker,et al.  Evaluation of Geiger-mode APDs for PET block detector designs , 2010, Physics in medicine and biology.