Ion sensing with thread-based potentiometric electrodes.
暂无分享,去创建一个
Mighten C Yip | G. Whitesides | S. Homer-Vanniasinkam | A. Ainla | M. P. Mousavi | Maral P. S. Mousavi | Yumi Yoshida | Christoffer K. Abrahamsson | Edward K. W. Tan | Mohamed K Abd El-Rahman | Li Yuan | H. Sigurslid | Nooralhuda Arkan | M. Mousavi | E. K. Tan | Haakon H. Sigurslid | Mighten C. Yip
[1] Alar Ainla,et al. Open-Source Potentiostat for Wireless Electrochemical Detection with Smartphones , 2018, Analytical chemistry.
[2] Percy Calvo-Marzal,et al. Ready-to-use single-strip paper based sensor for multiplex ion detection , 2018 .
[3] Seok Jae Lee,et al. Fabrication of newspaper-based potentiometric platforms for flexible and disposable ion sensors. , 2017, Journal of colloid and interface science.
[4] Daniel Citterio,et al. Fully Inkjet-Printed Paper-Based Potentiometric Ion-Sensing Devices. , 2017, Analytical chemistry.
[5] W. Qin,et al. Paper-based microfluidic sampling and separation of analytes for potentiometric ion sensing , 2017 .
[6] J. Raven. Chloride: essential micronutrient and multifunctional beneficial ion , 2016, Journal of experimental botany.
[7] P. Bühlmann,et al. Avoiding Errors in Electrochemical Measurements: Effect of Frit Material on the Performance of Reference Electrodes with Porous Frit Junctions. , 2016, Analytical chemistry.
[8] Andreas Stein,et al. A Disposable Planar Paper-Based Potentiometric Ion-Sensing Platform. , 2016, Angewandte Chemie.
[9] Tomàs Guinovart,et al. Wearable Potentiometric Sensors Based on Commercial Carbon Fibres for Monitoring Sodium in Sweat , 2016 .
[10] Christopher Beaudoin,et al. Clinically relevant analytical techniques, organizational concepts for application and future perspectives of point-of-care testing. , 2016, Biotechnology advances.
[11] Rongguo Yan,et al. Review of progresses on clinical applications of ion selective electrodes for electrolytic ion tests: from conventional ISEs to graphene-based ISEs , 2016 .
[12] Marta Novell,et al. Paper-based potentiometric ion sensors constructed on ink-jet printed gold electrodes , 2016 .
[13] A. Stein,et al. Rational design of all-solid-state ion-selective electrodes and reference electrodes , 2016 .
[14] M. Bergamini,et al. Low cost microfluidic device based on cotton threads for electroanalytical application. , 2016, Lab on a chip.
[15] Aaron R Wheeler,et al. DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration , 2015, PloS one.
[16] Eric Bakker,et al. All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples. , 2015, Analytical chemistry.
[17] Che-Hsin Lin,et al. Multiple enzyme-doped thread-based microfluidic system for blood urea nitrogen and glucose detection in human whole blood. , 2015, Biomicrofluidics.
[18] Philippe Bühlmann,et al. Ionic Liquid Reference Electrodes With a Well-Controlled Co(II)/Co(III) Redox Buffer as Solid Contact , 2015 .
[19] Andreas Stein,et al. All-solid-state reference electrodes based on colloid-imprinted mesoporous carbon and their application in disposable paper-based potentiometric sensing devices. , 2015, Analytical chemistry.
[20] Jianxiu Du,et al. A siphonage flow and thread-based low-cost platform enables quantitative and sensitive assays. , 2015, Lab on a chip.
[21] J. Bobacka,et al. Instrument-free control of the standard potential of potentiometric solid-contact ion-selective electrodes by short-circuiting with a conventional reference electrode. , 2014, Analytical chemistry.
[22] G. Whitesides,et al. Paper-based potentiometric ion sensing. , 2014, Analytical chemistry.
[23] S. Ng,et al. Simple thick-film thread-based voltammetric sensors , 2014 .
[24] Philippe Bühlmann,et al. Calibration-free ionophore-based ion-selective electrodes with a Co(II)/Co(III) redox couple-based solid contact. , 2014, Analytical chemistry.
[25] Alex Nemiroski,et al. Universal mobile electrochemical detector designed for use in resource-limited applications , 2014, Proceedings of the National Academy of Sciences.
[26] Samantha T. Mensah,et al. Nanomolar detection limits of Cd²⁺, Ag⁺, and K⁺ using paper-strip ion-selective electrodes. , 2014, Analytical chemistry.
[27] Andreas Stein,et al. Ion-selective electrodes with colloid-imprinted mesoporous carbon as solid contact. , 2014, Analytical chemistry.
[28] Beata Paczosa-Bator,et al. Effects of type of nanosized carbon black on the performance of an all-solid-state potentiometric electrode for nitrate , 2014, Microchimica Acta.
[29] Johan Bobacka,et al. Electrochemical control of the standard potential of solid-contact ion-selective electrodes having a conducting polymer as ion-to-electron transducer , 2014 .
[30] F. Rius,et al. A paper-based potentiometric cell for decentralized monitoring of Li levels in whole blood. , 2014, Lab on a chip.
[31] Che-Hsin Lin,et al. Thread-based microfluidic system for detection of rapid blood urea nitrogen in whole blood , 2014 .
[32] P. Bühlmann,et al. Solid contact ion-selective electrodes with a well-controlled Co(II)/Co(III) redox buffer layer. , 2013, Analytical chemistry.
[33] P. Bühlmann,et al. Reference electrodes with salt bridges contained in nanoporous glass: an underappreciated source of error. , 2013, Analytical chemistry.
[34] F. Rius,et al. Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes. , 2013, The Analyst.
[35] Beata Paczosa-Bator,et al. All-solid-state selective electrodes using carbon black. , 2012, Talanta.
[36] F. Rius,et al. Paper-based ion-selective potentiometric sensors. , 2012, Analytical chemistry.
[37] Philip A. Gale,et al. Supramolecular Chemistry: From Molecules to Nanomaterials , 2012 .
[38] J. Riu,et al. Potentiometric strip cell based on carbon nanotubes as transducer layer: toward low-cost decentralized measurements. , 2011, Analytical chemistry.
[39] E. Jaworska,et al. Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings. , 2011, Talanta.
[40] Kevin W. Plaxco,et al. CheapStat: An Open-Source, “Do-It-Yourself” Potentiostat for Analytical and Educational Applications , 2011, PloS one.
[41] J. Riu,et al. Determination of calcium ion in sap using carbon nanotube-based ion-selective electrodes. , 2010, The Analyst.
[42] G. Whitesides,et al. Thread as a matrix for biomedical assays. , 2010, ACS applied materials & interfaces.
[43] A. Stein,et al. Effects of architecture and surface chemistry of three-dimensionally ordered macroporous carbon solid contacts on performance of ion-selective electrodes. , 2010, Analytical chemistry.
[44] Wei Shen,et al. Thread as a versatile material for low-cost microfluidic diagnostics. , 2010, ACS applied materials & interfaces.
[45] F. Rius,et al. Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers. , 2008, Analytical chemistry.
[46] Rebecca M Reynolds,et al. Disorders of sodium balance , 2006, BMJ : British Medical Journal.
[47] Joseph Wang,et al. Electrochemical sensors for environmental monitoring: design, development and applications. , 2004, Journal of environmental monitoring : JEM.
[48] Johan Bobacka,et al. Solution-cast films of poly(3,4-ethylenedioxythiophene) as ion-to-electron transducers in all-solid-state ion-selective electrodes , 2004 .
[49] A. Michalska,et al. Lowering the Detection Limit of Ion-Selective Plastic Membrane Electrodes with Conducting Polymer Solid Contact and Conducting Polymer Potentiometric Sensors , 2003 .
[50] A. Ivaska,et al. Solid-contact ion-selective electrodes for aromatic cations based on pi-coordinating soft carriers. , 2002, Talanta.
[51] A. Ivaska,et al. Influence of oxygen and carbon dioxide on the electrochemical stability of poly(3,4-ethylenedioxythiophene) used as ion-to-electron transducer in all-solid-state ion-selective electrodes , 2002 .
[52] H. Hill,et al. Evaluating the separation of amphetamines by electrospray ionization ion mobility spectrometry/MS and charge competition within the ESI process. , 2002, Analytical chemistry.
[53] P. Bühlmann,et al. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. , 1998, Chemical reviews.
[54] M. Meyerhoff,et al. Influence of nonionic surfactants on the potentiometric response of ion-selective polymeric membrane electrodes designed for blood electrolyte measurements. , 1998, Analytical chemistry.
[55] Ernö Pretsch,et al. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.
[56] K. Cammann,et al. Disposable ion-selective electrodes , 1995 .
[57] Meinhard Knoll,et al. Potentiometric test strip , 1995 .
[58] K. Cammann,et al. Potentiometric biosensor in double matrix membrane technology , 1995 .
[59] O. Siggaard‐Andersen,et al. Ion-selective electrodes for sodium and potassium: a new problem of what is measured and what should be reported. , 1985, Clinical chemistry.
[60] B Walter,et al. Solid-phase reagent strips for detection of therapeutic drugs in serum by substrate-labeled fluorescent immunoassay. , 1983, Analytical chemistry.
[61] W. Simon,et al. Lifetime of neutral carrier based ion-selective liquid-membrane electrodes , 1980 .
[62] A. Hulanicki,et al. Calcium-selective electrodes with pvc membranes and solid internal contacts , 1976 .