Evaluating Muscle Activation Models for Elbow Motion Estimation

Adoption of wearable assistive technologies relies heavily on improvement of existing control system models. Knowing which models to use and how to improve them is difficult to determine due to the number of proposed solutions with relatively little broad comparisons. One type of these models, muscle activation models, describes the nonlinear relationship between neural inputs and mechanical activation of the muscle. Many muscle activation models can be found in the literature, but no comparison is available to guide the community on limitations and improvements. In this research, an EMG-driven elbow motion model is developed for the purpose of evaluating muscle activation models. Seven muscle activation models are used in an optimization procedure to determine which model has the best performance. Root mean square errors in muscle torque estimation range from 1.67–2.19 Nm on average over varying input trajectories. The computational resource demand was also measured during the optimization procedure, as it is an important aspect for determining if a model is feasible for use in a particular wearable assistive device. This study provides insight into the ability of these models to estimate elbow motion and the trade-off between estimation accuracy and computational demand.

[1]  Shahabeddin Vahdat,et al.  Investigating the properties of optimal sensory and motor synergies in a nonlinear model of arm dynamics , 2009, 2009 International Joint Conference on Neural Networks.

[2]  Warren E. Dixon,et al.  The Time-Varying Nature of Electromechanical Delay and Muscle Control Effectiveness in Response to Stimulation-Induced Fatigue , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[3]  Sun Baiqing,et al.  Dynamics modeling of human elbow joints servicing for rehabilitation robots , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[4]  Jianda Han,et al.  A novel EMG-driven state space model for the estimation of continuous joint movements , 2011, 2011 IEEE International Conference on Systems, Man, and Cybernetics.

[5]  Hemant J. Nagarsheth,et al.  Modeling and dynamics of human arm , 2008, 2008 IEEE International Conference on Automation Science and Engineering.

[6]  Antonie J. van den Bogert,et al.  Real-Time Simulation of Three-Dimensional Shoulder Girdle and Arm Dynamics , 2014, IEEE Transactions on Biomedical Engineering.

[7]  Matthew Millard,et al.  Flexing computational muscle: modeling and simulation of musculotendon dynamics. , 2013, Journal of biomechanical engineering.

[8]  D. Lloyd,et al.  An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo. , 2003, Journal of biomechanics.

[9]  David G. Lloyd,et al.  A real-time EMG-driven virtual arm , 2002, Comput. Biol. Medicine.

[10]  Jie Zhao,et al.  An elbow biomechanical model and its coefficients adjustment , 2014, 2014 IEEE 5th International Conference on Software Engineering and Service Science.

[11]  Torsten Bumgarner,et al.  Biomechanics and Motor Control of Human Movement , 2013 .

[12]  Sybert H. Stroeve,et al.  Impedance characteristics of a neuromusculoskeletal model of the human arm II. Movement control , 1999, Biological Cybernetics.

[13]  Franck Plestan,et al.  Distribution of forces between synergistics and antagonistics muscles using an optimization criterion depending on muscle contraction behavior. , 2010, Journal of biomechanical engineering.

[14]  Antonie J. van den Bogert,et al.  A Real-Time, 3-D Musculoskeletal Model for Dynamic Simulation of Arm Movements , 2009, IEEE Transactions on Biomedical Engineering.

[15]  K. Manal,et al.  A one-parameter neural activation to muscle activation model: estimating isometric joint moments from electromyograms. , 2003, Journal of biomechanics.

[16]  Jack M. Winters,et al.  Analysis of Fundamental Human Movement Patterns Through the Use of In-Depth Antagonistic Muscle Models , 1985, IEEE Transactions on Biomedical Engineering.

[17]  L. Schovanec,et al.  A Neuro-Muscular Elasto-Dynamic Model of the Human Arm Part 2: Musculotendon Dynamics and Related Stress Effects , 2009 .

[18]  Rong Song,et al.  Using recurrent artificial neural network model to estimate voluntary elbow torque in dynamic situations , 2005, Medical and Biological Engineering and Computing.

[19]  Zeng-Guang Hou,et al.  A dynamic EMG-torque model of elbow based on neural networks , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[20]  Joel C. Perry,et al.  Real-Time Myoprocessors for a Neural Controlled Powered Exoskeleton Arm , 2006, IEEE Transactions on Biomedical Engineering.

[21]  Panagiotis K. Artemiadis,et al.  Proportional Myoelectric Control of Robots: Muscle Synergy Development Drives Performance Enhancement, Retainment, and Generalization , 2015, IEEE Transactions on Robotics.

[22]  Dario Farina,et al.  High-Density Electromyography and Motor Skill Learning for Robust Long-Term Control of a 7-DoF Robot Arm , 2016, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[23]  Kejun Zhang,et al.  An Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control , 2014, Sensors.

[24]  M. Abderrahim,et al.  A Biomechanical Model to Aid Robot-Assisted Therapy of Upper Limb Impairment , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[25]  Jack M. Winters,et al.  An improved muscle-reflex actuator for use in large-scale neuromusculoskeletal models , 1995, Annals of Biomedical Engineering.

[26]  Arno H. A. Stienen,et al.  Implementation of EMG- and Force-Based Control Interfaces in Active Elbow Supports for Men With Duchenne Muscular Dystrophy: A Feasibility Study , 2016, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[27]  Arno H. A. Stienen,et al.  Design and control of the Active A-Gear: A wearable 5 DOF arm exoskeleton for adults with Duchenne muscular dystrophy , 2016, 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[28]  Pu Liu,et al.  Identification of Constant-Posture EMG–Torque Relationship About the Elbow Using Nonlinear Dynamic Models , 2012, IEEE Transactions on Biomedical Engineering.

[29]  Nicola Vitiello,et al.  NEUROExos: A Powered Elbow Exoskeleton for Physical Rehabilitation , 2013, IEEE Transactions on Robotics.

[30]  Panagiotis K. Artemiadis,et al.  Modeling anthropomorphism in dynamic human arm movements , 2010, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[31]  D. Childress,et al.  Relationships of the surface electromyogram to the force, length, velocity, and contraction rate of the cineplastic human biceps. , 1981, American journal of physical medicine.

[32]  D. Thelen Adjustment of muscle mechanics model parameters to simulate dynamic contractions in older adults. , 2003, Journal of biomechanical engineering.

[33]  Sybert H. Stroeve,et al.  Impedance characteristics of a neuromusculoskeletal model of the human arm I. Posture control , 1999, Biological Cybernetics.

[34]  Jie Zhao,et al.  An elbow-biomechanical modeling based on sEMG , 2014, Proceeding of the 11th World Congress on Intelligent Control and Automation.

[35]  David G Lloyd,et al.  Neuromusculoskeletal modeling: estimation of muscle forces and joint moments and movements from measurements of neural command. , 2004, Journal of applied biomechanics.

[36]  Yoshiaki Hayashi,et al.  Motion Estimation Based on EMG and EEG Signals to Control Wearable Robots , 2013, 2013 IEEE International Conference on Systems, Man, and Cybernetics.

[37]  Ana Luisa Trejos,et al.  Development of an EMG-driven control system for a wearable mechatronic elbow brace , 2016, 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI).