Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7T.

Localized high-resolution diffusion tensor images (DTI) from the midbrain were obtained using reduced field-of-view (rFOV) methods combined with SENSE parallel imaging and single-shot echo planar (EPI) acquisitions at 7T. This combination aimed to diminish sensitivities of DTI to motion, susceptibility variations, and EPI artifacts at ultra-high field. Outer-volume suppression (OVS) was applied in DTI acquisitions at 2- and 1-mm(2) resolutions, b=1000s/mm(2), and six diffusion directions, resulting in scans of 7- and 14-min durations. Mean apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured in various fiber tract locations at the two resolutions and compared. Geometric distortion and signal-to-noise ratio (SNR) were additionally measured and compared for reduced-FOV and full-FOV DTI scans. Up to an eight-fold data reduction was achieved using DTI-OVS with SENSE at 1mm(2), and geometric distortion was halved. The localization of fiber tracts was improved, enabling targeted FA and ADC measurements. Significant differences in diffusion properties were observed between resolutions for a number of regions suggesting that FA values are impacted by partial volume effects even at a 2-mm(2) resolution. The combined SENSE DTI-OVS approach allows large reductions in DTI data acquisition and provides improved quality for high-resolution diffusion studies of the human brain.

[1]  R. Ordidge,et al.  Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. , 1994, Magnetic resonance imaging.

[2]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[3]  Robert Turner,et al.  Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPA , 2010, Magnetic resonance in medicine.

[4]  L Kaufman,et al.  Inner volume MR imaging: technical concepts and their application. , 1985, Radiology.

[5]  Robert Turner,et al.  Single-shot diffusion imaging at 2.0 tesla , 1990 .

[6]  Bin Chen,et al.  Integrated SENSE DTI with correction of susceptibility- and eddy current-induced geometric distortions , 2008, NeuroImage.

[7]  S. Riederer,et al.  Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging , 1990, Magnetic resonance in medicine.

[8]  M. Zaitsev,et al.  High resolution single-shot EPI at 7T , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[9]  Yu-Chien Wu,et al.  Comparison of diffusion tensor imaging measurements at 3.0 T versus 1.5 T with and without parallel imaging. , 2006, Neuroimaging clinics of North America.

[10]  Duan Xu,et al.  Reduced field-of-view diffusion-weighted imaging of the brain at 7 T. , 2010, Magnetic resonance imaging.

[11]  Bennett A Landman,et al.  Diffusion tensor imaging at low SNR: nonmonotonic behaviors of tensor contrasts. , 2008, Magnetic resonance imaging.

[12]  Pratik Mukherjee,et al.  Single-shot fast spin-echo diffusion tensor imaging of the brain and spine with head and phased array coils at 1.5 T and 3.0 T. , 2004, Magnetic resonance imaging.

[13]  P. Basser,et al.  Diffusion tensor MR imaging of the human brain. , 1996, Radiology.

[14]  Essa Yacoub,et al.  Zoomed Functional Imaging in the Human Brain at 7 Tesla with Simultaneous High Spatial and High Temporal Resolution , 2002, NeuroImage.

[15]  P. Basser,et al.  Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. , 1996, Journal of magnetic resonance. Series B.

[16]  R. Goebel,et al.  7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images , 2001, Magnetic resonance in medicine.

[17]  大内 宏之 Diffusion anisotropy measurement of brain white matter is affected by voxel size : underestimation occurs in areas with crossing fibers , 2007 .

[18]  J. Finsterbusch High‐resolution diffusion tensor imaging with inner field‐of‐view EPI , 2009, Journal of magnetic resonance imaging : JMRI.

[19]  A. Panigrahy,et al.  Apparent Diffusion and Fractional Anisotropy of Diffuse Intrinsic Brain Stem Gliomas , 2010, American Journal of Neuroradiology.

[20]  Benoit M. Dawant,et al.  The adaptive bases algorithm for intensity-based nonrigid image registration , 2003, IEEE Transactions on Medical Imaging.

[21]  James G Pipe,et al.  Multishot diffusion‐weighted FSE using PROPELLER MRI , 2002, Magnetic resonance in medicine.

[22]  Petra Schmalbrock,et al.  DTI at 7 and 3 T: systematic comparison of SNR and its influence on quantitative metrics. , 2011, Magnetic resonance imaging.

[23]  David H. Miller,et al.  Contiguous‐slice zonally oblique multislice (CO‐ZOOM) diffusion tensor imaging: Examples of in vivo spinal cord and optic nerve applications , 2009, Journal of magnetic resonance imaging : JMRI.

[24]  Bradley P. Sutton,et al.  High resolution reduced-FOV Diffusion Tensor Imaging of the human pons with multi-shot variable density spiral at 3T , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Jin Hyung Lee,et al.  DWI of the spinal cord with reduced FOV single‐shot EPI , 2008, Magnetic resonance in medicine.

[26]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[27]  P Boesiger,et al.  Influence of SENSE on image properties in high‐resolution single‐shot echo‐planar DTI , 2006, Magnetic resonance in medicine.

[28]  Keiji Hashimoto,et al.  Voxel- and atlas-based analysis of diffusion tensor imaging may reveal focal axonal injuries in mild traumatic brain injury -- comparison with diffuse axonal injury. , 2012, Magnetic resonance imaging.

[29]  M R Symms,et al.  In vivo diffusion tensor imaging of the human optic nerve: Pilot study in normal controls , 2006, Magnetic resonance in medicine.

[30]  P. Boesiger,et al.  Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging , 2007, Magnetic resonance in medicine.

[31]  Robert Turner,et al.  3D DT‐MRI using a reduced‐FOV approach and saturation pulses , 2004, Magnetic resonance in medicine.

[32]  G C McKinnon,et al.  Optimized outer volume suppression for single‐shot fast spin‐echo cardiac imaging , 1998, Journal of magnetic resonance imaging : JMRI.

[33]  E. Kholmovski,et al.  High‐resolution DTI with 2D interleaved multislice reduced FOV single‐shot diffusion‐weighted EPI (2D ss‐rFOV‐DWEPI) , 2005, Magnetic resonance in medicine.

[34]  Patrick Hiepe,et al.  Diffusion weighted inner volume imaging of lumbar disks based on turbo-STEAM acquisition. , 2011, Zeitschrift fur medizinische Physik.

[35]  S J Riederer,et al.  Interleaved echo planar imaging on a standard MRI system , 1994, Magnetic resonance in medicine.

[36]  P. Boesiger,et al.  SENSE‐DTI at 3 T , 2004, Magnetic resonance in medicine.

[37]  P. Boesiger,et al.  Equi-ripple design of quadratic-phase RF pulses. , 2004, Journal of magnetic resonance.

[38]  Geoffrey Bodenhausen,et al.  Refocusing with chirped pulses for broadband excitation without phase dispersion , 1989 .

[39]  Roland Bammer,et al.  Diffusion tensor imaging using single‐shot SENSE‐EPI , 2002, Magnetic resonance in medicine.

[40]  Daniel L. Polders,et al.  Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla , 2011, Journal of magnetic resonance imaging : JMRI.

[41]  P. Boesiger,et al.  Design of broadband RF pulses with polynomial-phase response. , 2007, Journal of magnetic resonance.

[42]  Koichi Oshio,et al.  Phase errors in multi‐shot echo planar imaging , 1994, Magnetic resonance in medicine.

[43]  John C Gore,et al.  High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 T , 2013, Magnetic resonance in medicine.

[44]  Thomas R. Knösche,et al.  k-space and q-space: Combining ultra-high spatial and angular resolution in diffusion imaging using ZOOPPA at 7T , 2012, NeuroImage.