Described herein is a comprehensive project-a large-scale test of an integrated refrigeration and storage system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU LH2), sponsored by the Advanced Exploration Systems Program and constructed at Kennedy Space Center. A commercial cryogenic refrigerator interfaced with a 125,000 liter liquid hydrogen tank and auxiliary systems in a manner that enabled control of the propellant state by extracting heat via a closed loop Brayton cycle refrigerator coupled to a novel internal heat exchanger. Three primary objectives were demonstrating zero-loss storage and transfer, gaseous liquefaction, and propellant densification. Testing was performed at three different liquid hydrogen fill-levels. Data were collected on tank pressure, internal tank temperature profiles, mass flow in and out of the system, and refrigeration system performance. All test objectives were successfully achieved during approximately two years of testing. A summary of the final results is presented in this paper.
[1]
A. Swanger,et al.
Large scale production of densified hydrogen to the triple point and below
,
2017
.
[3]
Adam Swanger,et al.
ASME Section VIII Recertification of a 33,000 Gallon Vacuum-jacketed LH2 Storage Vessel for Densified Hydrogen Testing at NASA Kennedy Space Center
,
2015
.
[4]
Wesley L. Johnson,et al.
Integrated heat exchanger design for a cryogenic storage tank
,
2014
.
[5]
W. U. Notardonato,et al.
Operational Testing of Densified Hydrogen Using G‐M Refrigeration
,
2004
.
[6]
Wesley L. Johnson,et al.
Experimental Results of Integrated Refrigeration and Storage System Testing
,
2010
.