Structural performance of hybrid GFRP/steel concrete sandwich panels

Precast/prestressed concrete sandwich panels consist of two concrete wythes separated by a rigid insulation foam layer and are generally used as walls or slabs in thermal insulation applications. Commonly used connectors between the two wythes, such as steel trusses or concrete stems, penetrate the insulation layer causing a thermal bridge effect, which reduces thermal efficiency. Glass fiber-reinforced polymer (GFRP) composite shell connectors between the two concrete wythes are used in this research as horizontal shear transfer reinforcement. The design criterion is to establish composite action, in which both wythes resist flexural loads as one unit, while maintaining insulation across the two concrete wythes of the panel. The experiments carried out in this research show that hybrid GFRP/steel reinforced sandwich panels can withstand out-of-plane loads while providing resistance to horizontal shear between the two concrete wythes. An analytical method is developed for modeling the horizontal shear tra...