A novel approach for quantitative analysis of intracoronary optical coherence tomography: High inter‐observer agreement with computer‐assisted contour detection

Objective: This study aims to examine observer‐related variability of quantitative optical coherence tomography (OCT) derived measurements from both in vitro and in vivo pullback data. Background: Intravascular OCT is a new imaging modality using infrared light and offering 10 times higher image resolution (15 μm) compared to intravascular ultrasound. The quantitative analysis of in vivo intracoronary OCT imaging is complicated by the presence of blood, motion artifacts and the large quantity of information that has to be processed. Methods: We developed a standardized, automated quantification process for intracoronary OCT pullback data with inter‐observer variability assessed both in vitro by using postmortem human coronary arteries and in vivo by studying simple and complex coronary pathology and outcomes following stent implantation. The consensus between measurements by two observers was analyzed using the intraclass and interclass correlation coefficient and the reliability coefficients. Bland–Altman plots were generated to assess the relationship between variability and absolute measurements. Results: In vitro OCT assessment was performed in nine postmortem coronary arteries. The time needed for semiautomated contour detection of a 15‐mm long coronary segment was ∼40 min. The absolute and relative difference between lumen area measurements derived from two observers was low [0.02 ± 0.10 mm2; (0.3 ± 0.5)% respectively] with excellent correlation confirmed by linear regression analysis (R2 = 0.99; P < 0.001). Similarly, in vivo measurements demonstrated a high correlation with the main source of inter‐observer variation occurring as a result of coronary dissection and motion artifact. The absolute and relative difference between measurements were 0.11 ± 0.33 mm2 (1.57 ± 0.05)% for lumen area (R2 = 0.98; P < 0.001), 0.17 ± 0.68 mm2 (1.44 ± 0.08)% for stent area (R2 = 0.94; P < 0.001), and 0.26 ± 0.72 mm2 (14.08 ± 0.37)% for neointimal area (R2 = 0.78; P < 0.001). Conclusions: Highly accurate computer‐assisted quantitative analysis ofintracoronary OCT pullbacks is feasible with low inter‐observer variability. The presented approach allows for observer independent analysis of detailed vessel structures, and may be a valuable tool for future longitudinal studies incorporating OCT. © 2008 Wiley‐Liss, Inc.

[1]  Patrick W Serruys,et al.  Retrospective image‐based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method , 2004, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  Eiji Toyota,et al.  Assessment of coronary intima--media thickness by optical coherence tomography: comparison with intravascular ultrasound. , 2005, Circulation journal : official journal of the Japanese Circulation Society.

[3]  Brett E. Bouma,et al.  In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography , 2005, Circulation.

[4]  J. Schmitt,et al.  Imaging and characterization of coronary lesions with optical coherence tomography , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[5]  B E Bouma,et al.  Porcine coronary imaging in vivo by optical coherence tomography. , 2000, Acta cardiologica.

[6]  U. Siebert,et al.  Reproducibility of neointima quantification with motorized intravascular ultrasound pullback in stented coronary arteries. , 2000, American heart journal.

[7]  B E Bouma,et al.  Imaging of coronary artery microstructure (in vitro) with optical coherence tomography. , 1996, The American journal of cardiology.

[8]  Hiromasa Otake,et al.  Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. , 2007, European heart journal.

[9]  Nico Bruining,et al.  A novel approach to quantitative analysis of intra vascular ultrasound images , 2001, Computers in Cardiology 2001. Vol.28 (Cat. No.01CH37287).

[10]  B E Bouma,et al.  High resolution in vivo intra-arterial imaging with optical coherence tomography , 1999, Heart.

[11]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[12]  R. Whitbourn,et al.  Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting Stents: Serial Intravascular Ultrasound Analysis From the TAXUS II Trial , 2004, Circulation.

[13]  P. Serruys,et al.  Intravascular ultrasound evaluation after sirolimus eluting stent implantation for de novo and in-stent restenosis lesions. , 2004, European heart journal.

[14]  P. Serruys,et al.  Incomplete Stent Apposition After Implantation of Paclitaxel-Eluting Stents or Bare Metal Stents: Insights From the Randomized TAXUS II Trial , 2005, Circulation.

[15]  P. Serruys,et al.  In vivo validation of a novel three-dimensional quantitative coronary angiography system (CardiOp-B): comparison with a conventional two-dimensional system (CAAS II) and with special reference to optical coherence tomography. , 2007, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[16]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[17]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[18]  P. Serruys,et al.  Peristent Remodeling and Neointimal Suppression 2 Years After Polymer-Based, Paclitaxel-Eluting Stent Implantation: Insights From Serial Intravascular Ultrasound Analysis in the TAXUS II Study , 2005, Circulation.

[19]  U. Gerckens,et al.  Potential of a New High-Resolution Intracoronary Imaging Technique , 2003 .

[20]  C J Slager,et al.  ECG-gated three-dimensional intravascular ultrasound: feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans. , 1997, Circulation.

[21]  K. Seung,et al.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. , 2002, Journal of the American College of Cardiology.

[22]  Masanori Yamamoto,et al.  Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. , 2007, The American journal of cardiology.

[23]  Wolfgang Drexler,et al.  High resolution in vivo intra-arterial imaging with optical coherence tomography , 1999, Photonics West - Biomedical Optics.