System of automated gas-exchange analysis for the investigation of metabolic processes.

Conventional gas-exchange instruments are confined to the measurement of O(2) consumption (VO(2)) and CO(2) production (VCO(2)) and are subject to a variety of errors. This handicaps the performance of these devices at inspired O(2) fraction (FI(O(2))) > 0.40 and limits their applicability to indirect calorimetry only. We describe a device based on the automation of the Douglas bag technique that is capable of making continuous gas-exchange measurements of multiple species over a broad range of experimental conditions. This system is validated by using a quantitative methanol-burning lung model modified to provide reproducible (13)CO(2) production. The average error for VO(2) and VCO(2) over the FI(O(2)) range of 0.21-0.8. is 2.4 and 0.8%, respectively. The instrument is capable of determining the differential atom% volume of known references of (13)CO(2) to within 3.4%. This device reduces the sources of error that thwart other instruments at FI(O(2)) > 0. 40 and demonstrates the capacity to explore other expressions of metabolic activity in exhaled gases related to the excretion of (13)CO(2).

[1]  C. Mosse,et al.  A system for the continuous measurement of oxygen uptake and carbon dioxide output in artificially ventilated patients. , 1983, British journal of anaesthesia.

[2]  R M Gardner,et al.  Turbine flowmeter vs. Fleisch pneumotachometer: a comparative study for exercise testing. , 1987, Journal of applied physiology.

[3]  C. G. Douglas A method for determinng the total respiratory exchange in man. , 1911 .

[4]  J. Wilmore,et al.  Adequacy of the Haldane transformation in the computation of exercise V O2 in man. , 1973, Journal of applied physiology.

[5]  D. Schoeller,et al.  Application of a stable isotope (13C)-labeled glycocholate breath test to diagnosis of bacterial overgrowth and ileal dysfunction. , 1977, The Journal of laboratory and clinical medicine.

[6]  J. Wells,et al.  Precision and accuracy in a metabolic monitor for indirect calorimetry , 1998, European Journal of Clinical Nutrition.

[7]  S. Miodownik,et al.  Quantitative methanol-burning lung model for validating gas-exchange measurements over wide ranges of FIO2. , 1998, Journal of applied physiology.

[8]  C. Weissman,et al.  An in vitro evaluation of an instrument designed to measure oxygen consumption and carbon dioxide production during mechanical ventilation , 1994, Critical care medicine.

[9]  T. Reybrouck,et al.  Evaluation of breath-by-breath measurement of respiratory gas exchange in pediatric exercise testing. , 1992, Chest.

[10]  J. Sleigh,et al.  Breath-by-breath analysis of oxygen uptake using the Datex Ultima. , 1995, British journal of anaesthesia.

[11]  P. Paliard,et al.  Aminopyrine breath test: development of a 13C-breath test for quantitative assessment of liver function in humans. , 1995, Hepato-gastroenterology.

[12]  P C Beatty,et al.  Measurement of breath-by-breath gas exchange during general anaesthesia. , 1993, British journal of anaesthesia.

[13]  D. Schoeller,et al.  13C-trioctanoin: a nonradioactive breath test to detect fat malabsorption. , 1977, The Journal of laboratory and clinical medicine.

[14]  O. Norlander,et al.  Gas Exchange During Ventilator Treatment: a Validation of a Computerized Technique and its Comparison With the Douglas Bag Method , 1984, Acta anaesthesiologica Scandinavica.

[15]  D. Schoeller,et al.  Validation of 13CO2 breath analysis as a measurement of demethylation of stable isotope labeled aminopyrine in man. , 1978, Clinica chimica acta; international journal of clinical chemistry.