Comparison of multiple stereoscopic and monoscopic digital image formats to film for diabetic macular edema evaluation.

PURPOSE To assess agreement between evaluations of monoscopic and stereoscopic digital images versus stereo film photographs in diabetic macular edema (DME). METHODS A 152-eye group of digital monoscopic macular images (seven-field sets and wide-angle mosaics) were compared with digital stereoscopic images (uncompressed and compressed seven-field sets) and stereo 35-mm film photos (Early Treatment Diabetic Retinopathy Study protocol) for the presence of hard exudates (HE), retinal thickening (RT), clinically significant macular edema (CSME), and RT at the center of the macular (RTCM). RESULTS Agreement, according to the κ statistic, was almost perfect in identifying HE and RT between all digital formats and stereo film (HE, κ = 0.81-0.87; RT, κ = 0.87-0.92). Distribution in all digital formats was not significantly different from that in film (Bhapkar test: HE, P = 0.20-0.40; RT, P = 0.06-1.0). CSME and RTCM grading differences were either significant or trended toward significance. The readers detected CSME and RTCM in film images more often than in digital formats. In identifying DME features, agreement between evaluations of monoscopic digital formats and film was similar to that between stereo digital formats and film, and the performance of uncompressed images versus film was similar to that of compressed images versus film. Repeatability between readers was similar in evaluations of film and all digital formats. Repeatability in identifying RTCM was lower than that of other DME components in film and all digital formats. CONCLUSIONS Stereoscopic digital formats are equivalent to monoscopic for DME evaluation, but digital photography is not as sensitive as film in detecting CSME and RTCM.

[1]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[2]  M. Tennant,et al.  Identification of diabetic retinopathy by stereoscopic digital imaging via teleophthalmology: a comparison to slide film. , 2001, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[3]  P. L. Hildebrand,et al.  Clinical evaluation of patients with diabetic retinopathy: accuracy of the Inoveon diabetic retinopathy-3DT system. , 2002, Ophthalmology.

[4]  R. Klein,et al.  The 14-year incidence of visual loss in a diabetic population. , 1998, Ophthalmology.

[5]  F. Ferris,et al.  A severity scale for diabetic macular edema developed from ETDRS data. , 2008, Investigative ophthalmology & visual science.

[6]  H. Barlow Vision: A computational investigation into the human representation and processing of visual information: David Marr. San Francisco: W. H. Freeman, 1982. pp. xvi + 397 , 1983 .

[7]  PHOTOCOAGULATION FOR DIABETIC MACULAR EDEMA: EARLY TREATMENT DIABETIC RETINOPATHY STUDY REPORT NO. 4 , 1987, International ophthalmology clinics.

[8]  Lloyd Paul Aiello,et al.  Comparison of time-domain OCT and fundus photographic assessments of retinal thickening in eyes with diabetic macular edema. , 2008, Investigative ophthalmology & visual science.

[9]  Michael Larsen,et al.  Diabetic macular edema assessed with optical coherence tomography and stereo fundus photography. , 2002, Investigative ophthalmology & visual science.

[10]  Andrew Ting,et al.  Web-based grading of compressed stereoscopic digital photography versus standard slide film photography for the diagnosis of diabetic retinopathy. , 2007, Ophthalmology.

[11]  L. Aiello,et al.  Detection of diabetic macular edema. Ophthalmoscopy versus photography--Early Treatment Diabetic Retinopathy Study Report Number 5. The ETDRS Research Group. , 1989, Ophthalmology.

[12]  Alexander R de Leon,et al.  High-resolution stereoscopic digital fundus photography versus contact lens biomicroscopy for the detection of clinically significant macular edema. , 2002, Ophthalmology.

[13]  Adol Esquivel,et al.  GRADING DIABETIC RETINOPATHY SEVERITY FROM COMPRESSED DIGITAL RETINAL IMAGES COMPARED WITH UNCOMPRESSED IMAGES AND FILM , 2010, Retina.

[14]  Paul Sanghera,et al.  JPEG compression of stereoscopic digital images for the diagnosis of diabetic retinopathy via teleophthalmology. , 2004, Canadian journal of ophthalmology. Journal canadien d'ophtalmologie.

[15]  Timothy J. Vitale Projecting Digital 'Slide' Images , 2003 .

[16]  L. Aiello,et al.  Stereo nonmydriatic digital-video color retinal imaging compared with Early Treatment Diabetic Retinopathy Study seven standard field 35-mm stereo color photos for determining level of diabetic retinopathy. , 2001, Ophthalmology.

[17]  Larry D Hubbard,et al.  Brightness, contrast, and color balance of digital versus film retinal images in the age-related eye disease study 2. , 2008, Investigative ophthalmology & visual science.

[18]  G. Bresnick,et al.  A screening approach to the surveillance of patients with diabetes for the presence of vision-threatening retinopathy. , 2000, Ophthalmology.