Computational assessment of constraint in total knee replacement.

Anterior-posterior (AP) and internal-external (IE) rotational constraint of total knee replacement (TKR) components is frequently assessed experimentally in a multi-axis loading machine. This constraint is of clinical interest because it represents the contribution of the implants to passive joint constraint following surgery. A standard has been published to establish a uniform protocol of constraint testing (American Society of Testing and Materials (ASTM) International, 2005; Designation: F 1223-05. Standard Test Method for Determination of Total Knee Replacement). In the present study a dynamic computer simulation of a posterior-substituting TKR design undergoing an AP and IE range of constraint test was developed and tested. Implant surfaces in the simulation were specified based on the manufacturer's CAD representations, and contact between implants was computed using a rigid-body-spring-model formulation. Predictions of constraint force compared favorably to experimental values when the compliance of the testing frame was modeled. The simulated constraint test was then used to evaluate the selective locking of secondary degrees of freedom (motions other than AP displacement and IE rotation) during constraint testing. The published ASTM standard does not clearly define either the design of the testing machine to accommodate secondary motions or which coupled motions should be allowed. Predicted component constraint for a posterior cruciate-retaining TKR design was sensitive to both varus-valgus joint location and the combinations of allowed secondary motions. Computational prediction of implant constraint can expedite the design cycle and allow an objective comparison between TKR components tested in different locations.

[1]  M Beaugonin,et al.  Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. , 2002, Journal of biomechanics.

[2]  E. Chao,et al.  A comparison of different methods in predicting static pressure distribution in articulating joints. , 1997, Journal of biomechanics.

[3]  S J Piazza,et al.  Three-dimensional dynamic simulation of total knee replacement motion during a step-up task. , 2001, Journal of biomechanical engineering.

[4]  P S Walker,et al.  Inherent laxity in total knee prostheses. , 1987, The Journal of arthroplasty.

[5]  Mark Taylor,et al.  Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading. , 2007, Journal of biomechanics.

[6]  P. Walker,et al.  A computer model with surface friction for the prediction of total knee kinematics. , 1997, Journal of biomechanics.

[7]  T P Schmalzried,et al.  Rotational Constraint in Posterior-Stabilized Total Knee Prostheses , 2003, Clinical orthopaedics and related research.

[8]  P. Walker,et al.  The conflicting requirements of laxity and conformity in total knee replacement. , 1999, Journal of biomechanics.

[9]  P S Walker,et al.  Measurements of constraint of total knee replacement. , 2005, Journal of biomechanics.

[10]  G. Engh,et al.  Tibial insert undersurface as a contributing source of polyethylene wear debris. , 1997, Clinical orthopaedics and related research.

[11]  Jason P. Halloran,et al.  Explicit finite element modeling of total knee replacement mechanics. , 2005, Journal of biomechanics.

[12]  Benjamin J Fregly,et al.  Experimental evaluation of an elastic foundation model to predict contact pressures in knee replacements. , 2003, Journal of biomechanics.

[13]  D. Bartel,et al.  Stresses in polyethylene components of contemporary total knee replacements. , 1995, Clinical orthopaedics and related research.

[14]  T. Brown,et al.  Gait Cycle Finite Element Comparison of Rotating-Platform Total Knee Designs , 2003, Clinical orthopaedics and related research.

[15]  C. Jewett,et al.  Degradation of mechanical behavior in UHMWPE after natural and accelerated aging. , 2000, Biomaterials.

[16]  P S Walker,et al.  A computational model for the prediction of total knee replacement kinematics in the sagittal plane. , 2000, Journal of biomechanics.