Six dimensional X-ray Tensor Tomography with a compact laboratory setup

Attenuation based X-ray micro computed tomography (XCT) provides three-dimensional images with micrometer resolution. However, there is a trade-off between the smallest size of the structures that can be resolved and the measurable sample size. In this letter, we present an imaging method using a compact laboratory setup that reveals information about micrometer-sized structures within samples that are several orders of magnitudes larger. We combine the anisotropic dark-field signal obtained in a grating interferometer and advanced tomographic reconstruction methods to reconstruct a six dimensional scattering tensor at every spatial location in three dimensions. The scattering tensor, thus obtained, encodes information about the orientation of micron-sized structures such as fibres in composite materials or dentinal tubules in human teeth. The sparse acquisition schemes presented in this letter enable the measurement of the full scattering tensor at every spatial location and can be easily incorporated in...

[1]  Johann Kastner,et al.  Evaluation of Computed Tomography Data from Fibre Reinforced Polymers to Determine Fibre Length Distribution , 2011 .

[2]  Michael Campbell,et al.  Energy weighted x-ray dark-field imaging. , 2014, Optics express.

[3]  Nassir Navab,et al.  CAMPVis (cid:21) A Game Engine-inspired Research Framework for Medical Imaging and Visualization , 2014 .

[4]  Atsushi Momose,et al.  Distribution of unresolvable anisotropic microstructures revealed in visibility-contrast images using x-ray Talbot interferometry , 2011 .

[5]  F. Pfeiffer,et al.  X-ray dark-field imaging modeling. , 2012, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  Johann Kastner,et al.  Fibre structure characterisation of injection moulded short fibre-reinforced polymers by X-ray scatter dark field tomography , 2015 .

[7]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[8]  Thilo Michel,et al.  Reconstruction of scalar and vectorial components in X-ray dark-field tomography , 2014, Proceedings of the National Academy of Sciences.

[9]  Xavier Pennec,et al.  A Riemannian Framework for Tensor Computing , 2005, International Journal of Computer Vision.

[10]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[11]  Simon Zabler,et al.  Projection angle dependence in grating-based X-ray dark-field imaging of ordered structures. , 2013, Optics express.

[12]  Andreas Fehringer,et al.  Constrained X-ray tensor tomography reconstruction. , 2015, Optics express.

[13]  Franz Pfeiffer,et al.  Short-range order in mesoscale systems probed by X-ray grating interferometry , 2015 .

[14]  M. Strobl General solution for quantitative dark-field contrast imaging with grating interferometers , 2014, Scientific reports.

[15]  Atsushi Momose,et al.  Demonstration of X-Ray Talbot Interferometry , 2003 .

[16]  Franz Pfeiffer,et al.  Correlation of X-Ray Vector Radiography to Bone Micro-Architecture , 2014, Scientific Reports.

[17]  Franz Pfeiffer,et al.  Directional x-ray dark-field imaging , 2010, Physics in medicine and biology.

[18]  Marco Stampanoni,et al.  Non-invasive classification of microcalcifications with phase-contrast X-ray mammography , 2014, Nature Communications.

[19]  Kanti V. Mardia,et al.  DISTRIBUTIONS ON SPHERES , 1972 .

[20]  Franz Pfeiffer,et al.  X-ray tensor tomography , 2014 .