Point-of-care testing of cholesterol and triglycerides for epidemiologic studies: evaluation of the multicare-in system.
暂无分享,去创建一个
Pietro Amedeo Modesti | Stefano Rapi | P. Modesti | S. Rapi | Cristina Bazzini | Camilla Tozzetti | Valentina Sbolci | C. Bazzini | C. Tozzetti | V. Sbolci
[1] D. Altman,et al. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.
[2] G. Ronquist,et al. Multicentre evaluation of a non-wipe system for the rapid determination of total cholesterol in capillary blood, Accutrend Cholesterol on Accutrend GC. , 1995, European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies.
[3] W. Bablok,et al. A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part I , 1983, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie.
[4] C. Carlsson,et al. Inaccuracy of lipid measurements with the portable Cholestech L.D.X analyzer in patients with hypercholesterolemia. , 2002, Clinical chemistry.
[5] E. Bruck,et al. National Committee for Clinical Laboratory Standards. , 1980, Pediatrics.
[6] S. Yusuf,et al. Global burden of cardiovascular diseases: part I: general considerations, the epidemiologic transition, risk factors, and impact of urbanization. , 2001, Circulation.
[7] J. Ubbink,et al. Analytical quality of near-patient blood cholesterol and glucose determinations. , 2000, Clinical chemistry.
[8] Jan S Krouwer,et al. Setting performance goals and evaluating total analytical error for diagnostic assays. , 2002, Clinical chemistry.
[9] M. Shephard,et al. Comparative performance of two point-of-care analysers for lipid testing. , 2007, Clinical laboratory.
[10] Stephen Jan,et al. Global inequalities in access to cardiovascular health care: our greatest challenge. , 2008, Journal of the American College of Cardiology.
[11] James R. Taylor,et al. Cholesterol: Point-of-Care Testing , 2004, The Annals of pharmacotherapy.
[12] Claude Lenfant,et al. Definition of Metabolic Syndrome: Report of the National Heart, Lung, and Blood Institute/American Heart Association Conference on Scientific Issues Related to Definition , 2004, Arteriosclerosis, thrombosis, and vascular biology.
[13] R. Christenson,et al. Eight compact analysis systems evaluated for measuring total cholesterol. , 1994, Clinical chemistry.
[14] R. Heine,et al. Point-of-care testing of triglycerides: evaluation of the Accutrend triglycerides system. , 2000, Clinical chemistry.
[15] G. Boran,et al. Validation of a point of care lipid analyser using a hospital based reference laboratory , 2006, Irish journal of medical science.
[16] K. Reddy,et al. Cardiovascular disease in non-Western countries. , 2004, The New England journal of medicine.
[17] M. Shephard. Analytical Goals for Point-of-Care Testing Used for Diabetes Management in Australian Health Care Settings Outside The Laboratory , 2006 .
[18] Alan D. Lopez,et al. Alternative projections of mortality and disability by cause 1990–2020: Global Burden of Disease Study , 1997, The Lancet.
[19] J. Mckenney,et al. Analytic and Clinical Performance of Two Compact Cholesterol‐Testing Devices , 1998, Pharmacotherapy.
[20] C. Mathers,et al. Projections of Global Mortality and Burden of Disease from 2002 to 2030 , 2006, PLoS medicine.
[21] N. Rifai,et al. Impact of the third cholesterol report from the adult treatment panel of the national cholesterol education program on the clinical laboratory. , 2002, Clinical chemistry.
[22] Neil J Stone,et al. Implications of Recent Clinical Trials for the National Cholesterol Education Program Adult Treatment Panel III Guidelines , 2004, Circulation.