Accuracy of Optical Coherence Tomography Measurements of Rectus Muscle Insertions in Adult Patients Undergoing Strabismus Surgery.

PURPOSE To assess the accuracy of anterior segment optical coherence tomography (AS-OCT) in measuring the distance of extraocular muscle (EOM) insertion to the limbus to improve preoperative assessment of adult patients undergoing strabismus surgery. DESIGN Reliability analysis. METHODS setting: An institutional practice. PATIENT POPULATION Seventy-four adult patients scheduled for strabismus surgery on rectus muscles. OBSERVATION PROCEDURE The distance between the EOM insertion and the limbus was measured preoperatively with AS-OCT. The value was compared with the intraoperative measurement obtained with calipers. Additional measurements included the limbus-anterior chamber angle distance with AS-OCT and the axial length with IOLMaster. MAIN OUTCOME MEASURE Agreement between preoperative AS-OCT and intraoperative measurements. A difference of ≤1 mm was "clinically acceptable." RESULTS A total of 144 muscles were analyzed. Thirty-one of 33 reoperated muscles were successfully imaged. AS-OCT measurements were within 1 mm of intraoperative measurements in 77% of all muscles. The accuracy was higher for muscles with no prior surgery (83%), as compared with reoperated muscles (58%). Although the accuracy decreased when comparing reoperations to primary surgeries for the medial (79% to 63%; P = .09; 95% confidence interval [CI], -1.38 to 0.11) and the lateral rectus (81% to 49%; P = .11; 95% CI, -2.06 to 0.22), the difference was not significant. No correlation between limbus-anterior chamber angle distance and axial length was established. CONCLUSIONS AS-OCT is valuable in identifying EOM insertions in primary strabismus surgeries, but the accuracy decreases in reoperations.

[1]  A. Daxer,et al.  High-resolution magnetic resonance imaging of the normal extraocular musculature , 1997, Eye.

[2]  G. Lennerstrand,et al.  MRI measurements of normal extraocular muscles and other orbital structures , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.

[3]  S. Kraft,et al.  Evaluation of vertical rectus muscles using ultrasound biomicroscopy. , 2008, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[4]  S. Kraft,et al.  The accuracy of anterior segment optical coherence tomography (AS-OCT) in localizing extraocular rectus muscles insertions. , 2015, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[5]  S. Oh,et al.  Reproducibility of horizontal extraocular muscle insertion distance in anterior segment optical coherence tomography and the effect of head position. , 2014, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[6]  Yan Li,et al.  Clinical and research applications of anterior segment optical coherence tomography – a review , 2009, Clinical & experimental ophthalmology.

[7]  Savleen Kaur,et al.  Ultrasound Biomicroscopy in Strabismus Surgery: Efficacy in Postoperative Assessment of Horizontal Muscle Insertions , 2015, Strabismus.

[8]  S. Kraft,et al.  Evaluation of the ultrasound biomicroscope in strabismus surgery. , 2002, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[9]  J. García-Feijóo,et al.  Spectral domain optical coherence tomography to assess the insertion of extraocular rectus muscles. , 2016, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[10]  Agreement between intraoperative measurements and optical coherence tomography of the limbus-insertion distance of the extraocular muscles. , 2016 .

[11]  Ali Özgen,et al.  Normative measurements of orbital structures using CT. , 1998 .

[12]  E Viirre,et al.  Cine magnetic resonance imaging of ocular motility. , 1992, Journal of pediatric ophthalmology and strabismus.

[13]  Feyza Erenler,et al.  Anterior Segment Optical Coherence Tomography of the Horizontal and Vertical Extraocular Muscles With Measurement of the Insertion to Limbus Distance. , 2016, Journal of pediatric ophthalmology and strabismus.

[14]  L. Scullica,et al.  Ultrasound of the horizontal rectus muscle insertion sites: implications in preoperative assessment of strabismus. , 2003, Investigative Ophthalmology and Visual Science.

[15]  Kostadinka Bizheva,et al.  In vivo volumetric imaging of the human corneo-scleral limbus with spectral domain OCT , 2011, Biomedical optics express.

[16]  Ruikang K. Wang,et al.  In vivo microstructural and microvascular imaging of the human corneo-scleral limbus using optical coherence tomography , 2011, Biomedical optics express.

[17]  S. Kraft,et al.  Ultrasound biomicroscopy in strabismus reoperations. , 2006, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[18]  Fang Wang,et al.  Measurement of the limbus-insertion distance in adult strabismus patients with anterior segment optical coherence tomography. , 2011, Investigative ophthalmology & visual science.

[19]  S. Kraft,et al.  Localising rectus muscle insertions using high frequency wide-field ultrasound biomicroscopy , 2012, British Journal of Ophthalmology.