Low-noise current excitation sub-system for medical EIT

Electrical impedance tomography (EIT) has many potential applications in medicine. The sensitivity and spatial resolution of EIT can be enhanced significantly by increasing the measurement signal-to-noise ratio (SNR), to which a significant contribution is made by the SNR of the current excitation sub-system. In this paper we present a prototype EIT current excitation sub-system with 80 dB SNR, exploiting both digital and analogue techniques. It uses digital waveform synthesis, a 16-bit DAC and subsequent reconstruction filter, to drive an enhanced Howland current source. Detailed analysis and testing of the current sub-system are presented. Its output impedance is 10 MOmega for different load impedances, varying slowly over the frequency range from 10 kHz up to 4 MHz.

[1]  Robert Galambos,et al.  Resistance Shifts Accompanying the Evoked Cortical Response in the Cat , 1967, Science.

[2]  G.J. Saulnier,et al.  ACT3: a high-speed, high-precision electrical impedance tomograph , 1991, IEEE Transactions on Biomedical Engineering.

[3]  D S Holder,et al.  Current approaches to analogue instrumentation design in electrical impedance tomography , 1996, Physiological measurement.

[4]  Richard H. Bayford,et al.  Three-Dimensional Electrical Impedance Tomography of Human Brain Activity , 2001, NeuroImage.

[5]  Alexander S Ross,et al.  Current source design for electrical impedance tomography. , 2003, Physiological measurement.

[6]  R Galambos,et al.  Evoked resistance shifts in unanesthetized cats. , 1968, Experimental neurology.

[7]  H. McCann,et al.  Subsecond observations of EIT voltage changes on the human scalp due to brain stimulus , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  P. Wright,et al.  A study of composite electrode-tissue impedance , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Paul Wright,et al.  Low-noise measurement for electrical impedance tomography , 2007 .

[10]  Hugh McCann,et al.  Krylov subspace iterative techniques: on the detection of brain activity with electrical impedance tomography , 2002, IEEE Transactions on Medical Imaging.

[11]  Min-Wei Huang,et al.  A Multi-Frequency Current Source For Bioimpedance Application , .

[12]  H McCann,et al.  3D simulation of EIT for monitoring impedance variations within the human head. , 2000, Physiological measurement.

[13]  Lawrence M Knuckey,et al.  EPSM 2005 Workshop - IEC 60601-1: Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance - 3rd Edition 2005 , 2006 .

[14]  R Bragós,et al.  A wide-band AC-coupled current source for electrical impedance tomography. , 1994, Physiological measurement.

[15]  Kenneth A. Klivington,et al.  Effects of pharmacological agents on subcortical resistance shifts , 1975, Experimental Neurology.

[16]  Q. S. Zhu,et al.  High output impedance voltage controlled current source for bio-impedance instrumentation , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[17]  Sergio Franco,et al.  Design with Operational Amplifiers and Analog Integrated Circuits , 1988 .

[18]  R Galambos,et al.  Rapid resistance shifts in cat cortex during click-evoked responses. , 1968, Journal of neurophysiology.

[19]  P Bertemes-Filho,et al.  A comparison of modified Howland circuits as current generators with current mirror type circuits. , 2000, Physiological measurement.