Field Oriented Control-Based Reduction of the Vibration and Power Consumption of a Blood Pump

Power quality and energy efficiency are of great importance in motor control. The motor of any medical device needs to have a smooth torque and minimal vibration in order to maximise its energy efficiency and patient comfort. Furthermore, in rotary blood pumps, excessive energy wasted due to vibration is converted into uncontrolled movement of the mechanical parts and thus could reduce the life of the motor-pump. Besides mechanical or hydraulic origin, one of the causes of vibration in any pump is torque ripple resulting from motor phase commutation. In this paper, using relevant equipment, two extreme scenarios were examined for vibration and electrical efficiency comparison due to power quality in a blood pump: one trapezoidal control with a trapezoidal phase current output; the other a field oriented control (FOC) with a non-distorted sinusoidal phase current. The test motor-pump was the Arteriovenous Fistula Eligibility (AFE) System that is used prior to haemodialysis. The trapezoidal technique was implemented utilising the Allegro a4941 fan driver (Allegro Microsystem, 2012), and the FOC technique was implemented using the Texas Instrument digital signal processor (TMS320F28335). The aim was to reduce the energy wasted over vibration, and to achieve smooth operation of the AFE System. Vibration was measured with a one-axis accelerometer; results showed considerably lower vibration due to less current ripple associated with the FOC control as well as lower power consumption.

[1]  Hyun-Rok Cha,et al.  Analysis of Torque Ripple and Cogging Torque Reduction in Electric Vehicle Traction Platform Applying Rotor Notched Design , 2018, Energies.

[2]  Howard M Loree,et al.  In Vitro Study of a Medical Device to Enhance Arteriovenous Fistula Eligibility and Maturation , 2015, ASAIO journal.

[3]  Ralph Kennel,et al.  Implementation and experimental investigation of a sensorless field-oriented control scheme for permanent-magnet synchronous generators , 2018 .

[4]  Chern-Lin Chen,et al.  Automatic IM parameter measurement under sensorless field-oriented control , 1999, IEEE Trans. Ind. Electron..

[5]  Saad Mekhilef,et al.  Robust Speed Control of PMSM Using Sliding Mode Control (SMC)—A Review , 2019, Energies.

[6]  Wen Shi,et al.  Hybrid Space Vector Modulation Strategy for Torque Ripple Minimization in Three-Phase Four-Switch Inverter-Fed PMSM Drives , 2017, IEEE Transactions on Industrial Electronics.

[7]  Ozgur Ustun,et al.  On Field Weakening Performance of a Brushless Direct Current Motor with Higher Winding Inductance: Why Does Design Matter? , 2018 .

[8]  James F. Walton,et al.  Testing of a Centrifugal Blood Pump With a High Efficiency Hybrid Magnetic Bearing , 2003, ASAIO journal.

[9]  John Y. Hung,et al.  Design of currents to reduce torque ripple in brushless permanent magnet motors , 1993 .

[10]  Zhenbin Zhang,et al.  Advanced Control Strategies of Induction Machine: Field Oriented Control, Direct Torque Control and Model Predictive Control , 2018 .

[11]  Jangmyung Lee,et al.  A High-Speed Sliding-Mode Observer for the Sensorless Speed Control of a PMSM , 2011, IEEE Transactions on Industrial Electronics.

[12]  Larbi M’hamed,et al.  A Robust Sensorless Control of PMSM Based on Sliding Mode Observer and Model Reference Adaptive System , 2017 .

[13]  Ahmed Ramadhan Al-Obaidi Investigation of effect of pump rotational speed on performance and detection of cavitation within a centrifugal pump using vibration analysis , 2019, Heliyon.

[14]  Jonq-Chin Hwang,et al.  A Novel Cogging Torque Simulation Method for Permanent-Magnet Synchronous Machines , 2011 .

[15]  Muhammad Saad Rafaq,et al.  A Comprehensive Review of State-of-the-Art Parameter Estimation Techniques for Permanent Magnet Synchronous Motors in Wide Speed Range , 2020, IEEE Transactions on Industrial Informatics.

[16]  Lei Zhang,et al.  A New Torque Control Method for Torque Ripple Minimization of BLDC Motors With Un-Ideal Back EMF , 2008, IEEE Transactions on Power Electronics.

[17]  Gui-Jia Su,et al.  Low-cost sensorless control of brushless DC motors with improved speed range , 2004, IEEE Transactions on Power Electronics.

[18]  R. H. Park,et al.  Two-reaction theory of synchronous machines-II , 1933, Transactions of the American Institute of Electrical Engineers.

[19]  Abdul Rahim Abdullah,et al.  Efficiency Comparison of Trapezoidal and Sinusoidal Method for Brushless DC Motor Drive , 2015 .

[20]  Xing Liu,et al.  Analysis and Speed Ripple Mitigation of a Space Vector Pulse Width Modulation-Based Permanent Magnet Synchronous Motor with a Particle Swarm Optimization Algorithm , 2016 .

[21]  Marek Lazor,et al.  Modified field oriented control for smooth torque operation of a BLDC motor , 2014, 2014 ELEKTRO.

[22]  Yong Liu,et al.  Commutation-Torque-Ripple Minimization in Direct-Torque-Controlled PM Brushless DC Drives , 2006, IEEE Transactions on Industry Applications.

[23]  Cristian H. De Angelo,et al.  Voltage unbalance and harmonic distortion effects on induction motor power, torque and vibrations , 2016 .

[24]  Nesimi Ertugrul,et al.  Field-weakening performance of interior permanent-magnet motors , 2000 .

[25]  Pingping Zhu,et al.  A new method to minimize the commutation torque ripple in trapezoidal BLDC motor with sensorless drive , 2000, Proceedings IPEMC 2000. Third International Power Electronics and Motion Control Conference (IEEE Cat. No.00EX435).

[26]  Yi Li,et al.  Analysis of Vibrations in Interior Permanent Magnet Synchronous Motors Considering Air-Gap Deformation , 2017 .

[27]  Zhiguang Hua,et al.  A New Approach of Minimizing Commutation Torque Ripple for BLDCM , 2017 .

[28]  Asif Sabanoviç,et al.  Variable Structure Systems With Sliding Modes in Motion Control—A Survey , 2011, IEEE Transactions on Industrial Informatics.

[29]  Wen-Jun Xu Permanent Magnet Synchronous Motor with Linear QuadraticSpeed Controller , 2012 .

[30]  Wei Chen,et al.  Commutation Torque Ripple Suppression Strategy of Brushless DC Motor Considering Back Electromotive Force Variation , 2019, Energies.

[31]  Koji Kawahito Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure , 2013, Journal of Artificial Organs.