Variability of Retinal Thickness Measurements in Tilted or Stretched Optical Coherence Tomography Images

Purpose To investigate the level of inaccuracy of retinal thickness measurements in tilted and axially stretched optical coherence tomography (OCT) images. Methods A consecutive series of 50 eyes of 50 patients with age-related macular degeneration were included in this study, and Cirrus HD-OCT images through the foveal center were used for the analysis. The foveal thickness was measured in three ways: (1) parallel to the orientation of the A-scan (Tx), (2) perpendicular to the retinal pigment epithelium (RPE) surface in the instrument-displayed aspect ratio image (Ty), and (3) thickness measured perpendicular to the RPE surface in a native aspect ratio image (Tz). Mathematical modeling was performed to estimate the measurement error. Results The measurement error was larger in tilted images with a greater angle of tilt. In the simulation, with axial stretching by a factor of 2, Ty/Tz ratio was > 1.05 at a tilt angle between 13° to 18° and 72° to 77°, > 1.10 at a tilt angle between 19° to 31° and 59° to 71°, and > 1.20 at an angle ranging from 32° to 58°. Of note with even more axial stretching, the Ty/Tz ratio is even larger. Tx/Tz ratio was smaller than the Ty/Tz ratio at angles ranging from 0° to 54°. The actual patient data showed good agreement with the simulation. The Ty/Tz ratio was greater than 1.05 (5% error) at angles ranging from 13° to 18° and 72° to 77°, greater than 1.10 (10% error) angles ranging from 19° to 31° and 59° to 71°, and greater than 1.20 (20% error) angles ranging from 32° to 58° in the images axially stretched by a factor of 2 (b/a = 2), which is typical of most OCT instrument displays. Conclusions Retinal thickness measurements obtained perpendicular to the RPE surface were overestimated when using tilted and axially stretched OCT images. Translational Relevance If accurate measurements are to be obtained, images with a native aspect ratio similar to microscopy must be used.

[1]  Srinivas R Sadda,et al.  Accuracy and reproducibility of automated drusen segmentation in eyes with non-neovascular age-related macular degeneration. , 2012, Investigative ophthalmology & visual science.

[2]  Masahiro Akiba,et al.  Macular choroidal thickness and volume in normal subjects measured by swept-source optical coherence tomography. , 2011, Investigative ophthalmology & visual science.

[3]  Effect of angle of incidence on macular thickness and volume measurements obtained by spectral-domain optical coherence tomography. , 2012, Investigative ophthalmology & visual science.

[4]  G. Savini,et al.  The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT , 2011, British Journal of Ophthalmology.

[5]  Jennifer I. Lim,et al.  Relationship between optical coherence tomography-measured central retinal thickness and visual acuity in diabetic macular edema. , 2007, Ophthalmology.

[6]  T. Röck,et al.  Influence of axial length on thickness measurements using spectral-domain optical coherence tomography. , 2014, Investigative ophthalmology & visual science.

[7]  Eun Suk Lee,et al.  Influence of Cataract on Time Domain and Spectral Domain Optical Coherence Tomography Retinal Nerve Fiber Layer Measurements , 2010, Journal of glaucoma.

[8]  S. Sadda,et al.  Intraretinal segmentation on fourier domain optical coherence tomography. , 2010, Annals of the Academy of Medicine, Singapore.

[9]  Eric A. Swanson,et al.  Quantitative Assessment of Macular Edema With Optical Coherence Tomography , 1995 .

[10]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[11]  Zhihong Hu,et al.  Multiple layer segmentation and analysis in three-dimensional spectral-domain optical coherence tomography volume scans , 2013, Journal of biomedical optics.

[12]  Maciej Wojtkowski,et al.  Tissue thickness calculation in ocular optical coherence tomography. , 2016, Biomedical optics express.

[13]  N. Yoshimura,et al.  Potential Measurement Errors Due to Image Enlargement in Optical Coherence Tomography Imaging , 2015, PloS one.

[14]  N. Yoshimura,et al.  Application of extended field imaging to optical coherence tomography. , 2015, Ophthalmology.

[15]  Milan Sonka,et al.  Adjustment of the retinal angle in SD-OCT of glaucomatous eyes provides better intervisit reproducibility of peripapillary RNFL thickness. , 2013, Investigative ophthalmology & visual science.

[16]  N. Yoshimura,et al.  Parallelism as a novel marker for structural integrity of retinal layers in optical coherence tomographic images in eyes with epiretinal membrane. , 2014, American journal of ophthalmology.

[17]  M. Akiba,et al.  Association between shape of sclera and myopic retinochoroidal lesions in patients with pathologic myopia. , 2012, Investigative ophthalmology & visual science.

[18]  Armin Wolf,et al.  Megahertz ultra-wide-field swept-source retina optical coherence tomography compared to current existing imaging devices , 2014, Graefe's Archive for Clinical and Experimental Ophthalmology.

[19]  J. Fujimoto,et al.  Ultrahigh-resolution ophthalmic optical coherence tomography , 2001, Nature Medicine.

[20]  J. Fujimoto,et al.  Optical coherence tomography of the human retina. , 1995, Archives of ophthalmology.

[21]  S. Sadda,et al.  PROGRESSION OF MACULAR ATROPHY IN PATIENTS WITH NEOVASCULAR AGE-RELATED MACULAR DEGENERATION UNDERGOING ANTIVASCULAR ENDOTHELIAL GROWTH FACTOR THERAPY , 2016, Retina.

[22]  Christian Y Mardin,et al.  Correlation between local glaucomatous visual field defects and loss of nerve fiber layer thickness measured with polarimetry and spectral domain OCT. , 2009, Investigative ophthalmology & visual science.

[23]  R. Huber,et al.  Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser. , 2011, Optics express.

[24]  Hiroshi Ishikawa,et al.  A Problem of Proportions in OCT-Based Morphometry and a Proposed Solution , 2016, Investigative ophthalmology & visual science.

[25]  C. Cheung,et al.  Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy. , 2007, Investigative ophthalmology & visual science.

[26]  Jeong W. Pak,et al.  Effect of optical coherence tomography scan decentration on macular center subfield thickness measurements. , 2013, Investigative ophthalmology & visual science.

[27]  Ziqiang Wu,et al.  Image quality affects macular and retinal nerve fiber layer thickness measurements on fourier-domain optical coherence tomography. , 2011, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.